About the RediStik® ECMO Cannulation Trainer
An anatomically accurate model designed for pediatric ECMO neck cut down, cannulation, connection to ECMO circuit, and de-cannulation in patients weighing 18-25 kg. It accommodates 15Fr arterial, 15-17Fr venous, and 20Fr VV cannulas. Features include a single-use neck simulator with realistic tissue layers and a reusable transparent heart for visualization during procedures.
Parts Overview
The trainer kit includes a duffle bag, heart with fittings, securement base, ECMO heart case, necks/vessels/vagus nerves, spare vessel set, color tabs, liquid soap, and instructions. The neck and vessels are single-use, while other components are reusable.
Set-Up/Use Instructions
Setup requires the included heart/base, neck, and fittings, along with additional supplies like towels and surgical instruments. Key steps involve loading vessels into the neck simulator, attaching the heart, and priming the system. Proper lubrication and alignment are crucial for successful simulation.
Storage
Reusable components should be cleaned and dried before storage. The heart should be drained and placed in the protector case within the duffle bag. Proper maintenance ensures longevity and performance of the trainer.
Contact and Reorder Information
For orders and customer service, contact Sawbones via their website or phone numbers provided for different regions. Various kit configurations and replacement parts are available for reorder.
See more

Catalog excerpts

RediStik-ECMO-1

ECMO Cannulation Trainer ABOUT THE RediStik® ECMO CANNULATION TRAINER PARTS OVERVIEW TRAINER SET-UP/USE INSTRUCTIONS STORAGE CONTACT AND REORDER INFORMATION Visit sawbones.com for more information, including set-up videos and skills overview

 Open the catalog to page 1
RediStik-ECMO-2

1. ABOUT THE RediStik® ECMO CANNULATION TRAINER Anatomically accurate design provides all steps for Pediatric ECMO neck cut down, cannulation, connection to ECMO circuit and de-cannulation in an 18-25 kg patient. Model accommodates 15Fr arterial, 15-17Fr venous and 20Fr VV cannulas. THIS TRAINER FEATURES: Neck simulator (single use): • Right side of neck with anatomically accurate landmarks (mandible, clavicle, SCM) • Realistic tissue layers (skin, fat, platysma, SCM and vagal) for cutting and spreading to expose the vessels. SCM can be spread, cut or encircled and laterally retracted to expose...

 Open the catalog to page 2
RediStik-ECMO-3

3. SET-UP/USE INSTRUCTIONS Trainer set-up is the same for the RediStik® ECMO Cannulation Trainer without 3D Heart. 1. Supplies needed: Included in kit — heart/base, new neck, reusable IJV/Carotid fittings, lubricating jelly, liquid soap, color tabs used to prime ECMO circuit (less likely to stain that traditional dyes). Not included in kit — towels, absorbent pads, vessel loading instrument (tubing clamp), surgical drape/towels/4x4, 1Liter bag/extension tubing, surgical instruments. 2. Load vessels into neck simulator: 1. Apply 1-2 packets of lubricating jelly inside neck openings with 8" or...

 Open the catalog to page 3
RediStik-ECMO-4

3. Attaching heart and priming: 8. Lubricate inside both vessels (DO NOT SKIP THIS STEP): slowly drip liquid soap inside vessels, gently insert a cannula to lubricate cannula and vessel, drip more soap into vessel opening and gently slide cannula inside vessel once more, dry off any soap on outside of vessel that connects to heart. 9. Connect both vessels to the heart by pushing vessel with tubing sheath into heart/vessel connection. Once both vessels are connected to the heart, fit the two-metal post on bottom of the heart to the two matching holes in the base. Next gently work out vessel slack...

 Open the catalog to page 4
RediStik-ECMO-5

Reloading neck for another simulation: IJV/Carotid fittings/stop-cock should be saved and used on new neck. 1. Draining model by placing IV bag below heart and opening up both vessel stop-cocks. 2. Once partially drained, disconnect heart from neck/vessels. 3. Remove superior vessel stop-cock fittings and dry off soap residue from fittings before connecting to new IJV/Carotid. 4. Dry off residual soap from heart coupler connections. 5. Repeat set-up steps. 4. STORAGE 1. Save and reuse vessel stop-cock/fittings. 2. Wash out soap and colored water thoroughly from inside heart. 3. Drain and dry...

 Open the catalog to page 5
RediStik-ECMO-6

5. CONTACT AND REORDER Contact: texaschildrens.org/redistik Order/reorder: visit sawbones.com Sawbones Customer Service USA (servicing North America, South America, Asia and Australia): (206) 463-5551 / [email protected], 6 am – 5 pm, PT Sawbones Customer Service EMEA (servicing Europe, Middle East and Africa): +46 40 650 7000 / [email protected], 8 am – 5 pm, CET • RediStik® ECMO Cannulation Trainer Kit: Item #1846-10 • RediStik® ECMO Cannulation Trainer Kit without 3D Heart: Item #1846-20 • RediStik® ECMO Neck Replacement (single use): Item #1846 • RediStik® ECMO IJV/Carotid Extra Set (single...