ECMO Cannulation Trainer ABOUT THE RediStik® ECMO CANNULATION TRAINER PARTS OVERVIEW TRAINER SET-UP/USE INSTRUCTIONS STORAGE CONTACT AND REORDER INFORMATION Visit sawbones.com for more information, including set-up videos and skills overview
Open the catalog to page 11. ABOUT THE RediStik® ECMO CANNULATION TRAINER Anatomically accurate design provides all steps for Pediatric ECMO neck cut down, cannulation, connection to ECMO circuit and de-cannulation in an 18-25 kg patient. Model accommodates 15Fr arterial, 15-17Fr venous and 20Fr VV cannulas. THIS TRAINER FEATURES: Neck simulator (single use): • Right side of neck with anatomically accurate landmarks (mandible, clavicle, SCM) • Realistic tissue layers (skin, fat, platysma, SCM and vagal) for cutting and spreading to expose the vessels. SCM can be spread, cut or encircled and laterally retracted to...
Open the catalog to page 23. SET-UP/USE INSTRUCTIONS Trainer set-up is the same for the RediStik® ECMO Cannulation Trainer without 3D Heart. 1. Supplies needed: Included in kit — heart/base, new neck, reusable IJV/Carotid fittings, lubricating jelly, liquid soap, color tabs used to prime ECMO circuit (less likely to stain that traditional dyes). Not included in kit — towels, absorbent pads, vessel loading instrument (tubing clamp), surgical drape/towels/4x4, 1Liter bag/extension tubing, surgical instruments. 2. Load vessels into neck simulator: 1. Apply 1-2 packets of lubricating jelly inside neck openings with 8"...
Open the catalog to page 33. Attaching heart and priming: 8. Lubricate inside both vessels (DO NOT SKIP THIS STEP): slowly drip liquid soap inside vessels, gently insert a cannula to lubricate cannula and vessel, drip more soap into vessel opening and gently slide cannula inside vessel once more, dry off any soap on outside of vessel that connects to heart. 9. Connect both vessels to the heart by pushing vessel with tubing sheath into heart/vessel connection. Once both vessels are connected to the heart, fit the two-metal post on bottom of the heart to the two matching holes in the base. Next gently work out vessel...
Open the catalog to page 4Reloading neck for another simulation: IJV/Carotid fittings/stop-cock should be saved and used on new neck. 1. Draining model by placing IV bag below heart and opening up both vessel stop-cocks. 2. Once partially drained, disconnect heart from neck/vessels. 3. Remove superior vessel stop-cock fittings and dry off soap residue from fittings before connecting to new IJV/Carotid. 4. Dry off residual soap from heart coupler connections. 5. Repeat set-up steps. 4. STORAGE 1. Save and reuse vessel stop-cock/fittings. 2. Wash out soap and colored water thoroughly from inside heart. 3. Drain and...
Open the catalog to page 55. CONTACT AND REORDER Contact: texaschildrens.org/redistik Order/reorder: visit sawbones.com Sawbones Customer Service USA (servicing North America, South America, Asia and Australia): (206) 463-5551 / info@sawbones.com, 6 am – 5 pm, PT Sawbones Customer Service EMEA (servicing Europe, Middle East and Africa): +46 40 650 7000 / info@sawbones.se, 8 am – 5 pm, CET • RediStik® ECMO Cannulation Trainer Kit: Item #1846-10 • RediStik® ECMO Cannulation Trainer Kit without 3D Heart: Item #1846-20 • RediStik® ECMO Neck Replacement (single use): Item #1846 • RediStik® ECMO IJV/Carotid Extra Set...
Open the catalog to page 6All Sawbones/Pacific Research Labs catalogs and technical brochures
-
Alex-Labrum
2 Pages
-
TKS
1 Pages
-
FioNA
2 Pages
-
Solid Clear Models
17 Pages
-
Pediatric Catalog
8 Pages
-
Arthroscopy Catalog
12 Pages
-
SPINE SURGICAL SKILLS MODELS
18 Pages
-
BIOMECHANICAL TEST MATERIALS
16 Pages
-
GENERAL CATALOG
88 Pages