Product catalog summary
Overview of μCT Systems:
The document provides specifications for μCT 45 and μCT 90 systems, both utilizing cone-beam geometry with peak energy ranging from 30-90 kVp. The focal spot size is 5/7 μm at 4/8 W for both models. An optional filter changer with three positions is available.

Scanning Capabilities:
μCT 45 offers a scan diameter of 10-50 mm, while μCT 90 extends up to 10-90 mm. Both systems support a maximum scan length/height of 120 mm and can accommodate samples with a maximum diameter/height of 90/120 mm. The automatic sample changer can hold up to 20 holders for μCT 45 and 16 holders for μCT 90, with multiple specimens up to 9 cm in diameter.

Resolution and Imaging:
The nominal resolution for μCT 45 is 1.25 μm with a 10% MTF of less than 5 μm, whereas μCT 90 offers a nominal resolution of 2.2 μm with a 10% MTF of less than 8 μm. The image matrix ranges from 512 x 512 to 8192 x 8192 for both systems. Options include compression/tension and cooling devices.

Computing Specifications:
The systems are powered by an HP Integrity Server, 64-bit rx2800, with RAM ranging from 32 to 368 GB and CPU configurations from 1 to 2 CPUs with 4 to 16 cores. Disk storage ranges from 5 TB to multiple TBs. An optional GPU for reconstruction is available with HP Z4/Z8 equipped with Pascal GPUs. Clustering of multiple rx2800 servers is possible to enhance throughput.

Manufacturer Information:
SCANCO Medical AG, located in Brüttisellen, Switzerland, and SCANCO USA, Inc., located in Wayne, PA, USA, are the manufacturers. Contact details and websites are provided for further information.

Additional Notes:
The document mentions a specific configuration for μCT 45 with a 10mm field of view, 3μm resolution, and 70 kVp.
See more

Catalog excerpts

μCT 45 - μCT 90-2

Specifications Systems Geometry Peak Energy Focal Spotsize Filter Changer (3 positions) Scan Diameter Max. Scan Length / Height Max. Sample Ø / Height Automatic Sample Changer Cone-Beam Cone-Beam 30-90 kVp 30-90 kVp 5/7 μm (@4/8 W) 5/7 μm (@4/8 W) optional optional 10-50 mm 10-90 mm 120 mm 120 mm 90/120 mm 90/120 mm up to 20 holders up to 16 holders with multiple specimens with multiple specimens up to 9 cm Ø up to 9 cm Ø 1.25 μm / <5 μm 2.2 μm / <8 μm 512 x 512 512 x 512 8192x8192 8192x8192 compression/tension and cooling device Resolution (Nominal /10% MTF) Image Matrix : from to Options: Computing...

 Open the catalog to page 2