µCT 50 / µCT 100

µCT 50 / µCT 100

µCT 50 / µCT 100

Product catalog summary
Specifications Overview

General Information:
Manufacturer: SCANCO Medical AG, Switzerland
Contact: +41 44 805 98 00 (Switzerland), 610 688 1440 (USA)
Website: www.scanco.ch, www.microct.com

System Models:
1. μCT 50
2. μCT 100

Geometry and Energy:
Both models utilize Cone-Beam geometry with a peak energy range of 30-90 kVp. They feature variable focal spot sizes from 5-30 μm (4-18W) and include a filter changer with options for Al, Mb, Cu, or none.

Scanning Capabilities:
μCT 50: Scan diameter of 4-50 mm, maximum scan length/height of 160 mm.
μCT 100: Scan diameter of 10-105 mm, maximum scan length/height of 160 mm.
Both models support an automatic sample changer for up to 12 holders with multiple specimens.

Resolution and Image Matrix:
μCT 50: Nominal resolution of 500 nanometers, <2 μm at 10% MTF.
μCT 100: Nominal resolution of 1.25 μm, <4 μm at 10% MTF.
Image matrix ranges from 512 x 512 to 8192 x 8192 for both models.

Computing Specifications:
Both models are equipped with HP Integrity Servers (64 bit) with options for rx2660/rx3600 or bl860/bl870 configurations.
RAM: μCT 50 supports 4 to 32/96 GB, μCT 100 supports 4 to 256 GB.
CPU: μCT 50 supports 1 to 4 CPUs, μCT 100 supports 1 to 32 CPUs.
Disk capacity ranges from 300 GB to multiple TB for both models.
Reconstruction time is 3 seconds for 1k x 1k images using 1 CPU, with typical analysis time of 5 minutes.
Clustering of multiple servers is possible to enhance throughput.

Applications:
μCT 50 is suitable for cortical bone imaging at 1 μm resolution.
μCT 100 is designed for larger field of view applications, such as human femur imaging with a 100 mm FOV and 30 μm voxel size.
See more

Catalog excerpts

µCT 50 / µCT 100-2

Specifications Systems μCT 50 Geometry Peak Energy Variable Focal Spotsize Filter Changer (Al, Mb, Cu, None) Scan Diameter Max. Scan Length/Height Automatic Sample Changer Resolution (Nom. /10% MTF) Image Matrix : from to Cone-Beam 30-90 kVp 5-30 μm (4-18W) yes 4-50 mm 160 mm up to 12 holders with multiple specimens 500 nanometer / <2 μm 512 x 512 8192x8192 Cone-Beam 30-90 kVp 5-30 μm (4-18W) yes 10-105 mm 160 mm up to 12 holders with multiple specimens 1.25 μm / <4 μm 512 x 512 8192x8192 μCT 100, human femur, 100 mm FOV, 30 μm voxelsize Computing HP Integrity Server, 64 bit RAM CPU Disks Reconstruction...

 Open the catalog to page 2

All Scanco Medical catalogs and technical brochures

  1. vivaCT 80

    2  Pages

  2. XtremeCT II

    4  Pages

  3. µCT Systems

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.