µCT Systems

µCT Systems

µCT Systems

Product catalog summary
Overview: The document provides detailed information about Scanco's MicroCT systems and software, highlighting their applications, specifications, and capabilities. These systems are used for bone quality measurements, nondestructive testing, implant measurements, dental research, and more.
Applications: The systems are applicable in various fields such as bone quality measurements, nondestructive testing, implant measurements, dental research, scaffold development, advanced composite materials, and vascular research.
System Features: The MicroCT systems offer high-resolution scanning with non-destructive analysis, no sample preparation, high throughput, and custom configurations. They include automatic sample changers and physiological monitoring for specific models.
Specifications: The document lists specifications for various models, including μCT 35, 40, 50, 80, 100, vivaCT 40, 75, 80, and XtremeCT II. Key parameters include peak energy, maximum scan diameter, scan length, resolution, and image matrix size.
Software Capabilities: The software supports morphometry and density measurements, contact area calculations, pore analysis, and visualization in 2D and 3D. It also includes finite element analysis.
Global Reach: Over 300 systems are installed worldwide in leading academic and industrial laboratories. Scanco Medical also offers contract scan services and quality assurance/image analysis services for multi-site studies.
Computing and Performance: The systems use HP Integrity Servers with varying RAM and CPU configurations. They support high-capacity archival devices and offer fast reconstruction and analysis times.
Additional Information: Specialized specimen holders, quality control protocols, and optional features are available for all scanners. The document also provides contact information for Scanco Medical in Switzerland and the USA.
See more

Catalog excerpts

µCT Systems-1

MicroCT Systems and Software

 Open the catalog to page 1
µCT Systems-2

Scanco - Scanners, Software and Contract Research Services: Applications: - Bone quality measurements - Nondestructive testing - Implant measurements - Dental research - Scaffolds - Development of advanced composite materials - Vascular research murine cortical bone 1 m voxelsize High resolution scanners for accurate results: - Non-Destructive analysis - No sample preparation required - High throughput (batch mode processing, automatic sample loader) - Custom system configuration available - Very fast acquisition, reconstruction and analyses - Automatic sample changer (CT 35, 40, 50, 80 and CT...

 Open the catalog to page 2
µCT Systems-3

MicroTomography Systems |j.CT 50 (mouse tibia) |aCT 40 (mouse brain, blood vessel cast) XtremeCT (human hand) XtremeCT II (cortical porosity radius) vivaCT 80 (mouse knee) |aCT 40 (dental implant)

 Open the catalog to page 3
µCT Systems-4

Specifications Specimen Systems Peak Energy Max. Scan Diameter Max. Scan Length/Height Automatic Sample Changer Option Resolution (Nom. /10% MTF) Minimal Scan Time per Stack Image Matrix : from to Peak Energy Variable Spotsize Filter Changer (Al, Mb, Cu, None) Max. Scan Diameter Max. Scan Length/Height Automatic Sample Changer Option Resolution (Nom. /10% MTF) Image Matrix : from to Peak Energy Max. Scan Diameter Max. Scan Length Resolution (Nom./10% MTF) Minimal Scan Time per Stack Image Matrix : from to XtremeCT II * Peak Energy Max. Scan Diameter Max. Scan Length Resolution (Nom./10% MTF)...

 Open the catalog to page 4