Machine QA

Machine QA

Machine QA

Product catalog summary
Overview: The document discusses the advanced capabilities of the Delta4 system for machine Quality Assurance (QA) in radiotherapy technology. It highlights the system's efficiency, accuracy, and ability to perform comprehensive QA tasks quickly.
Advanced Machine QA: The Delta4 system allows for rapid and periodic machine QA, enabling users to analyze the constancy of therapy machines. Measurements can be compared with Treatment Planning System (TPS) data or reference measurements. The system supports the creation of a DICOM RT Plan file for comprehensive QA routines, which can be stored and reused.
Stability Check: Delta4 offers high accuracy in measuring each dose pulse, allowing detailed analysis of accelerator start-up behavior. The system provides flexibility in viewing start-up behavior and stability over time, with the ability to extract and parameterize profiles and depth doses.
Beam Constancy and MLC Performance: The system checks beam constancy at various gantry angles and performs MLC performance checks using a film-free picket fence test. The high spatial resolution of the diode detectors ensures accurate measurement of MLC leaf positions.
Long-term Effects and Trends: Delta4 enables tracking of long-term trends in beam parameters through periodic QA measurements. Trend diagrams help in identifying continuous degradation or changes in beam parameters.
Pre-treatment Verification: Delta4 is also suitable for pre-treatment verification, supporting VMAT, including Varian RapidArc™, TomoTherapy®, and IMRT. It provides instant dosimetric information and facilitates efficient commissioning of new accelerators and treatment planning systems.
Testimonial: Dr. Vladimir Feygelman from Moffitt Cancer Center praises Delta4 for its clever design and ability to provide comprehensive dosimetric information quickly, aiding in the commissioning and QA of new systems.
See more

Catalog excerpts

Machine QA-1

Delta4 moves machine QA to an advanced and efficient level: • • • • • • Advanced machine QA done in a few minutes Stability check with high accuracy and detailed analysis Beam constancy at various gantry angles MLC performance check at various gantry angles Film-free picket fence test Discover and track long-term effects and trends

 Open the catalog to page 1
Machine QA-2

Advanced machine QA done in a few minutes The Machine QA option for your Delta4 system coupled with the advanced hardware of the Delta4 system allows the user to perform periodic machine QA and analyze the constancy of therapy machines. At any time, measurements can be compared with TPS data or a reference measurement, typically obtained after maintenance and acceptance of the machine. The measurement can be run directly in the RT machine’s service mode, setting up the configuration directly in Delta4. Alternatively, the Machine QA option lets the user create a DICOM RT Plan file including all...

 Open the catalog to page 2
Machine QA-3

Beam constancy at various gantry angles Traditionally, machine QA is often limited to the upright gantry position. With the Delta4 Machine QA option, beam constancy can be checked at various gantry angles (e.g., compare data from four different projections). MLC performance check in various gantry angles and picket fence test The picket fence test was originally used to check the reproducibility of leaf gap between opposite MLC leaves using a radiographic film. In Delta4, this test is now expanded yet made easy. A DICOM RT Plan file is created in the Delta4 software to run the MLC leafs in a...

 Open the catalog to page 3
Machine QA-4

RapidArc™ is a trademark of Varian Medical Systems. TomoTherapy ® is a registered trademark of ThomoTherapy Inc. We had an opportunity to thoroughly evaluate the Delta4 dosimeter prior to clinical use. We have validated it for step-and-shoot IMRT and TomoTherapy, with good results. The design of the device is very clever and a great deal of dosimetric information is available virtually instantaneously after the plan is delivered. The major advantage is the ability to compare dose at the fraction, beam or even individual segment levels, which allows to quickly evaluate and explain any disagreements....

 Open the catalog to page 4