Power Entry Modules with Line Filter https://www.schurter.com /PG06 IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole, Line Switch 2-pole Screw-on mounting horizontal (version B) Screw-on mounting vertical (version A) Snap-in mounting Unique Selling Proposition Other versions on request - Panel mount : Screw-on from front side - 4 Functions : Appliance Inlet Protection class I , Line Switch 2-pole , Fuseholder for fuse-links 5 x 20 mm 1‑ or 2‑pole , Line filter in standard and medical version - V-Lock notch standard - Quick connect terminals 6.3 x 0.8 mm - Various mounting options Attractive flat design Switch for highest inrush current V-Lock cord retaining - Ultra-compact design. Ideal for low profile designs Aluminum case provides good shielding - All single elements are already wired - Ideal for application with high transient loads - For applications according IEC/UL 62368-1 we recommend variants with bleed resistor Suitable for use in medical equipment according to IEC/UL 60601-1 (1 MOOP, 1 MOPP) - Solder terminals Other rocker marking Line switch, illuminated Line switch 1-pole Medical Version (M80) Class X1- and Y1-capacitors for enhanced withstand voltage Alternative: version without line filter DD11 Alternative: version for snap-in mounting KMF Alternative: version with 2-stage filter DD14 pdf data sheet, html datasheet, General Product Information, Approvals, Distributor-Stock-Check, Accessories, Detailed request for product Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temperature Climatic Category IP-Protection Protection Class Terminal Panel Thickness S 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 °C to 85 °C 25/085/21 acc. to IEC 60068-1 front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on mounting: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1 mm to 3 mm Thermoplastic, black, UL 94V-0 Appliance inlet/-outlet Rated Power Acceptance @ Ta 23 °C Power Acceptance @ Ta > 23°C Line Switch Line Filter C14 acc. to IEC 60320-1 UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I 1-/2-pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 mm 5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per pole Admissible power acceptance at higher ambient temperature see derating curves Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical Details Standard and Medical Version, IEC 60939, UL 60939-3, CSA C22.2 no. 8 Technical Details > 2'000'000 h acc. to MIL-HB-217 F
Open the catalog to page 1
Power Entry Modules with Line Filter https://www.schurter.com /PG06 Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be...
Open the catalog to page 2
Power Entry Modules with Line Filter https://www.schurter.com /PG06 Compliances The product complies with following Guide Lines Identification The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. UKCA declaration of conformity The UKCA marking declares that the product complies with the applicable requirements laid down in the British Amendment of Regulation (EC) 765/2008. Directive RoHS 2011/65/EU, Amendment (EU) 2015/863 China RoHS The law SJ / T...
Open the catalog to page 3
Power Entry Modules with Line Filter https://www.schurter.com /PG06 Snap-in mounting from front side
Open the catalog to page 4
Power Entry Modules with Line Filter https://www.schurter.com /PG06 Technical Data of Filter-Components Rated Current [A] Standard version Standard version Standard version Standard version Standard version Standard version Standard Version with Ground Line Choke Standard Version with Ground Line Choke Diagrams Standard Version, medical Version M80 Non-illuminated Medical Version (M5) Non-illuminated Standard Version, medical Version M80 with PE-choke Medical Version (M5) with PE-choke Admissible power acceptance in Watt Admissible power acceptance in Watt
Open the catalog to page 5
Power Entry Modules with Line Filter https://www.schurter.com /PG06 Attenuation Loss - - - - 50Ω differential mode _____ 50Ω common mode Standard version Line Switch Order Number Standard version Standard version Standard version Standard version Standard version Standard version Standard version Standard version Standard version Standard version illuminated, green Standard version Standard version Standard version
Open the catalog to page 6
Power Entry Modules with Line Filter https://www.schurter.com /PG06 Line Switch Order Number Standard version Standard version Standard version Standard version Standard version Standard version Standard version Standard version Standard version Standard version Standard version Standard version Standard version Standard version Standard version Standard version Standard version Standard version Standard Version with Ground Line Choke Standard Version with Ground Line Choke █ Most Popular. Availability for all products can be searched real-time:...
Open the catalog to page 7
Power Entry Modules with Line Filter https://www.schurter.com /PG06 Required Accessory Description Fusedrawer_2 Fusedrawer for Fuse Links 5x20 mm, with or without Voltage Selector Insert Fingergrip, 2-pole Wire_Harness Wire harness for SCHURTER products Assorted_Covers Rear Cover 0859.0076 RC320 Rear Cover for Power Entry Module Cord_retaining_kits Cord retaining strain relief Flat head, A Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete 4787, Mounting: Screw-on mounting, Appliance Outlet: IEC Solder terminals, 10 A, Suitable for appliances with protection...
Open the catalog to page 8All Schurter catalogs and technical brochures
-
FPBB RAIL
7 Pages
-
FMAD CP
6 Pages
-
DT31
5 Pages
-
DKIH-1
6 Pages
-
CSO
4 Pages
-
4783
4 Pages
-
4750
5 Pages
-
3-108-993
3 Pages
-
MSS
7 Pages
-
5121
6 Pages
-
THS
5 Pages
-
MSM II
14 Pages
-
5120
12 Pages
-
DG12
12 Pages
-
6080
4 Pages
-
RESISTIVE TOUCHSCREENS
1 Pages
-
PCAP TOUCHSCREENS
1 Pages
-
CHS
6 Pages
-
5707
8 Pages
-
Fuses
5 Pages
-
Metal Line Switches
6 Pages
-
Connectors (Inlets/Outlets)
4 Pages