evoduo prime - 1

schwarzer cardiotek SMART. PRECISE. RELIABLE. evoduo prime Combined system for hemodynamic and electrophysiological studies evoduo prime was designed with exceptional functionality specifically for the modern heart catheterization lab. This workstation combines two systems in one: the hemodynamics system and an EP-TRACER system for electrophysiology. The modular design of the system provides an efficient, space-saving workstation that provides outstanding functionality and signal quality. Features of evoduo prime HEMODYNAMICS Intuitive operation via functional keyboard This proven interface is the centerpiece of the system: • The single keyboard covers all processes - from measuring up to report generation • Intuitive graphical elements increase ease of use • Measurement locations in the heart are defined on the heart graphic with corresponding functional buttons. At the push of a button you can (for example); • Access curve segments • View input reports for O2 saturations • Switch between ECG and blood pressure measuring ranges and signal amplitudes Measurement • Access signal sections • View input reports for O2 saturations • Switch between ECG and blood pressure measuring ranges and signal amplitudes In addition to the 12 standard measuring positions, additional measurement locations can be configured and analyzed using the various test algorithms. Calculation The calculated parameters include: • pressure gradient, cardiac output, vascular resistance • valve areas, body surface area and systemic and pulmonary flows during shunt evaluation The algorithms and formulas for the hemodynamic results can be edited by the user. All edited values go into the final calculations. Full Disclosure File All signals are recorded and, after completion of the investigation, can be retrospectively evaluated and documented in full. ELECTROPHYSIOLOGY EP-TRACER amplifiers offer the connection of either 20, 52 or 84 intracardiac channels. The brilliant signal quality supports you throughout the EP procedure. Integrated stimulator The EP-TRACER incorporates a built-in 2-channel stimulator within its compact design. Stimulation of any intracardiac channel is achieved with the click of the mouse, without need for further external wiring or equipment. Stimulation protocols are easily customized and accessed, thus further streamlining the procedural workflow. Measurement and evaluation The software allows you to view, store and analyze both surface and intracardiac ECG signals. Special display modes, such as the triggered mode or partitioned screen mode, are designed for the optimal display of data from various examination types. The connection of any commonly used radiofrequency ablator allows for treatment of arrhythmias. Stimulation and ablation events are automatically recorded, allowing for a more efficient and effective way of working. GENERAL Interfaces HL7 (Health Level 7) • Exchange patient data from HIS to the patient database of the evo system via HL7 ADT • Transfer the investigation reports from the evo system to the HIS via HL7 MDM DICOM (Digital Imaging and Communications in Medicine) • All patient data can be transferred through the DICOM Work list Management (WLM) to x-ray stations, • All patient data from x-ray stations can be transferred to the evo system using the DICOM Modality Performed Procedure Step (MPPS) • Transmission of the report to an image archive (PACS) schuuarzer Schwarzer Cardiotek GmbH, Im Zukunftspark 3, 74076 Heilbronn, Germany Quality Management System smart. precise, reliable. Email info@schwarzercardiotek.com, www.schwarzercardiotek.com Directive 93/42/EWG Ann

Open the catalog to page 1
evoduo prime - 2

Technical details Components • Cabinet housing • Central interface unit • Power supply, 230V • Transformer isolation • PC • Patient connection box • EP-TRACER • Functional keyboard DE / EN / FR • Laser printer • Mouse • Uninterruptible power supply; APC Smart-UPS 1500W / 230V • Options • Vitals monitor for Cardiac • Output, NiBP, SpO2 • Laser printer (color) • Cabling • Serial connection cable for patient connection box • Standard accessories • Transducer • Catheter connection boxes (EP) • 4 carbon fiber cables L = 90cm • Adhesive electrodes • 2 monitoring cables (pressure signals) • 1...

Open the catalog to page 2

All Schwarzer CardioTek catalogs and technical brochures

  1. evoduo natal

    2 Pages

  2. evoprime

    2 Pages

  3. evosuperior

    2 Pages

  4. evoelement

    2 Pages

  5. evoprime+

    2 Pages

  6. evonatal

    2 Pages

  7. EP-TRACER 38

    1 Pages