The starter model of the Schwarzer Cardiotek hemo system series The evoelement is equipped with all basic functions for the modern cardiac cath lab and meets the requirement of a clearly arranged recording and display of basic hemodynamic data. Perfomance characteristics of evoelement Measurements The ECG signal is continuously measured in real-time, enabling an immediate reaction to an ischemic condition. Due to the stabilization of the zero position (can be switched on/off), reliable results can be obtained even under rough circumstances. Manual measuring Manual adjustment of measured sections 12 standard measuring positions Examination room displays Standard Interfaces Next to the real-time signals, the monitor displays all measurements jointly with their respective conditions, easy to be monitored by the operator in the examination room. HL7 (Health Level 7), optional • Transfer of patient data from HIS to evoelement • ransfer of examination report from evoelement to HIS T For reporting purposes the system automatically populates a procedure log during the case, which also allows for manual additions. DICOM (Digital Imaging and Communications in Medicine) • Via DICOM Work List Management (WLM) patient data is transferred to the imaging modality • Via DICOM Modality Performed Procedure Step (MPPS) the dose information is transferred from the modality to evoelement and documented in the report • Via DICOM PACS the report is transferred and stored on the PACS. Calculations Calculated parameters are: • Pressure measurement • Cardiac-Output • Vascular Resistance • Bodysurface Area BSA Algorithms and formulas can be edited by the user; retrospectively changed values will be considered for the calculations. Schwarzer Cardiotek GmbH, Im Zukunftspark 3, 74076 Heilbronn, Germany Phone: +49 7131 2774 500 | Fax: +49 7131 2774 590 Email: info@schwarzercardiotek.com, www.schwarzercardiotek.com Quality Management System EN ISO 13485:2012, EN ISO13485:2012/AC:2012 Directi

Open the catalog to page 1
evoelement - 2

The starter model of the Schwarzer Cardiotek hemo system series Technical Specs Classification acc to European MDD (93/42/EWG): Patient connection box, Preamplifier ECG Amplifier Number of amplifiers Sampling rate IBP Amplifier Number of amplifiers Components Base Unit (Chassis) • Central Interface Unit • Power Supply, 230V • Isolation Transformer • PC 1 x 19“ TFT-Monitor Patient Headbox Standard Keyboard Laserprinter Mouse UPS; APC-Smart-UPS 1500W/230V Options • Vitalmonitor for CardiacOutput, NiBP, SPO2 • (Colour-)Laserprinter Standard Accesories • Transducer • ECG adhesive electrodes • 2...

Open the catalog to page 2

All Schwarzer CardioTek catalogs and technical brochures

  1. evoduo prime

    2 Pages

  2. evoduo natal

    2 Pages

  3. evoprime

    2 Pages

  4. evosuperior

    2 Pages

  5. evoprime+

    2 Pages

  6. evonatal

    2 Pages

  7. EP-TRACER 38

    1 Pages