evoprime+ - 1

The starter model for comprehensive procedures in the cardiac cath lab, with two monitors evoprime+ is equipped with comprehensive functionalities for the modern cardiac cath lab, meeting the need for an intuitive operation combined with automatic calculation algorithms. It is valued for its brilliance in signal acquisition and signal representation. Perfomance characteristics of evoprime+ Intuitive operation via extended function keyboard • • • • One single keyboard for the entire workflow – from measuring to reporting Quick access to relevant curve sections by means of button commands Editing the oxygen saturation of the relevant heart section by one-button-functionality Switching between various measuring intervals, changing the gain of the ECG-signal and sweep speed happens by pushing a single button A utomatic and simultaneous recording of signal sections M anual and automatic measuring Manual adjustment of measured sections Automatic assignment of pullback curves In addition to 12 standard measuring positions, further measuring points are configurable. The common measuring algorithms can be freely assigned to the newly generated positions. Examination room displays Next to the real-time signals, the slave monitor displays all measurements jointly with their respective conditions, easy to be monitored by the operator in the examination room. For reporting purposes the system automatically populates a procedure log during the case, which also allows for manual additions. Calculations Calculated parameters are: • Pressure gradients • Cardiac-Output Vascular Resistance Valve Opening Area S ystemic and Pulmonal Flow Shunts Bodysurface Area BSA Algorithms and formulas can be edited by the user; retrospectively changed values will be considered for the calculations. ECG Signal Management The ECG signal is continuously measured in real-time, enabling an immediate reaction to an ischemic condition. Due to the stabilization of the zero position (can be switched on/off), reliable results can be obtained even under rough circumstances. Full Disclosure File All signals are automatically recorded in “full disclosure mode”; therefore the whole data set can be reviewed and analyzed retrospectively after examination. Standard Interfaces HL7 (Health Level 7), optional • Transfer of patient data from HIS to evoprime+ • ransfer of examination report from evoprime+ to HIS T DICOM (Digital Imaging and Communications in Medicine) • Via DICOM Work List Management (WLM) patient data is transferred to the imaging modality • Via DICOM Modality Performed Procedure Step (MPPS) the dose information is transferred from the modality to evoprime+ and documented in the report • Via DICOM PACS the report is transferred and stored on the PACS. Schwarzer Cardiotek GmbH, Im Zukunftspark 3, 74076 Heilbronn, Germany Phone: +49 7131 2774 500 | Fax: +49 7131 2774 590 Email: info@schwarzercardiotek.com, www.schwarzercardiotek.com Quality Management System EN ISO 13485:2012, EN ISO1348

Open the catalog to page 1
evoprime+ - 2

The starter model for comprehensive procedures in the cardiac cath lab, with two monitors Technical Specs Classification acc to European MDD (93/42/EWG): Patient connection box, Preamplifier ECG Amplifier Number of amplifiers Sampling rate IBP Amplifier Number of amplifiers Base Unit (Chassis) • Central Interface Unit • Power Supply, 230V • Isolation Transformer • PC Signal Display Number of channels Recording programs ECG Derivations Amplification Range of heart rate 2 x 19“ TFT-Monitors Patient Headbox Function Keyboard DE/EN/FR Laserprinter Mouse UPS; APC-Smart-UPS 1500W/230V Invasive...

Open the catalog to page 2

All Schwarzer CardioTek catalogs and technical brochures

  1. evoduo prime

    2 Pages

  2. evoduo natal

    2 Pages

  3. evoprime

    2 Pages

  4. evosuperior

    2 Pages

  5. evoelement

    2 Pages

  6. evonatal

    2 Pages

  7. EP-TRACER 38

    1 Pages