evosuperior
2Pages

{{requestButtons}}

Catalog excerpts

evosuperior - 1

schuuarzer cardiotek SMART. PRECISE. RELIABLE. evosuperior High-end heart cathlab system two monitors, two PCs evosuperior has been designed to meet highest requirements for state-of-the-art diagnosis and analysis in left and right heart cath procedures. The system comprises of recording, measurement and calculation of hemodynamic parameters It is valued for its brilliance in signal acquisition and signal representation. Intuitive operation via extended function keyboard • One single keyboard for the entire workflow - from measuring to reporting • Quick access to relevant curve sections by means of button commands • Editing the oxygen saturation of the relevant heart section by one-button-functionality • Switching between various measuring intervals, changing the gain of the ECG-signal and sweep speed happens by pushing a single button Measurements • Automatic and simultaneous recording of signal sections • Manual and automatic measuring • Manual adjustment of measured sections • Automatic assignment of pullback curves In addition to 12 standard measuring positions, further measuring points are configurable. The common measuring algorithms can be freely assigned to the newly generated positions. Examination room displays Next to the real-time signals, the slave monitor displays all measurements jointly with their respective conditions, easy to be monitored by the operator in the examination room. For reporting purposes the system automatically populates a procedure log during the case, which also allows for manual additions. Calculations Calculated parameters are: Pressure gradients Cardiac-Output Vascular Resistance Valve Opening Area Systemic and Pulmonal Flow Shunts Bodysurface Area BSA Algorithms and formulas can be edited by the user; retrospectively changed values will be considered for the calculations. ECG Signal Management The ECG signal is continuously measured in real-time, enabling an immediate reaction to an ischemic condition. Due to the stabilization of the zero position (can be switched on/off), reliable results can be obtained even under rough circumstances. Full Disclosure File All signals are automatically recorded in “full disclosure mode"; therefore the whole data set can be reviewed and analyzed retrospectively after examination. Safety concept The evosuperior is equipped with two separate computer systems. In the unlikely event of a system crash, the secondary system takes over the online monitoring function. This concept guarantees a safe and monitored termination of the examination by displaying ECG and the vital parameters as well as hemodynamic signals. Standard Interfaces HL7 (Health Level 7), optional • Transfer of patient data from HIS to evosuperior • Transfer of examination report from evosuperior to HIS DICOM (Digital Imaging and Communications in Medicine) • Via DICOM Work List Management (WLM) patient data is transferred to the imaging modality • Via DICOM Modality Performed Procedure Step (MPPS) the dose information is transferred from the modality to evosuperior and documented in the report • Via DICOM PACS the report is transferred and stored on the PACS. Quality Management System EN ISO 13485:2012, EN IS013485:2012/AC.2012 Directive 93/42/EWG Annex II schwarzer Schwarzer Cardiotek GmbH, Im Zukunftspark 3, 74076 Heilbronn. Germany cardiotek Phone: +49 7131 2774 500 | Fax:+49 7131 2774 590 sMAic^wosf'wuAlau Email: info@schwarzercardiotek.com, www.schwarzercardiotek.com

Open the catalog to page 1
evosuperior - 2

Technical Specs Components • Base Unit (Chassis) • Central Interface Unit • Power Supply, 230V • Isolation Transformer • 2 PCs 2x19“ TFT-Monitors Patient Headbox Function Keyboard DE/EN/FR Laserprinter Mouse UPS; APC-Smart-UPS 1500W/230V • Options • Vitalmonitor for Cardiac-Output, NiBP, SPO? • (Colour-)Laserprinter • Cabling • Serial connection cable to patient headbox • 4 carbon fibre cables (radio transluscent), length= 90cm • Standard Accesories • Transducer • ECG adhesive electrodes • 2 pressure cables • 1 mounting set for 2 pressure-transducers • ECG patient cable with electrode leads...

Open the catalog to page 2

All Schwarzer CardioTek catalogs and technical brochures

  1. evoduo prime

    2 Pages

  2. evoduo natal

    2 Pages

  3. evoprime

    2 Pages

  4. evoelement

    2 Pages

  5. evoprime+

    2 Pages

  6. evonatal

    2 Pages

  7. EP-TRACER 38

    1 Pages