SciCan autoclave overview brochure
4Pages

{{requestButtons}}

Catalog excerpts

SciCan autoclave overview brochure - 1

Happy endings are written at 134°C. Unless of course you’re a germ. When your body ghts infection, it drives up its temperature to make the environment less hospitable. SciCan’s range of sterilizers also turn up the heat, to 134ºC, to help eliminate viruses and microorganisms on your instruments. Patented technology speeds up instrument sterilization – to as much as 10x faster than most conventional chambered autoclaves. So the happy ending, is also a quick one.

Open the catalog to page 1
SciCan autoclave overview brochure - 2

STATIM 2000 – Rapid and compact for small practices STATIM ® 2000 benets: Ultra fast 6 minute unwrapped cycle • 14 minute wrapped cycle • Exceptional instrument turnover • 10 minute Dri-TecC drying Technology • Single use water • Aseptic transfer of instruments directly to the point-of-use • Reduced instrument investment • Choice of external printer or datalogger • STATIM 5000 – All you need for the mid-sized practice STATIM 5000 benets: Ultra fast 9 minute unwrapped cycle 17.5 minute wrapped cycle • Exceptional instrument turnover • 15 minute Dri-TecR drying Technology • Single use water •...

Open the catalog to page 2
SciCan autoclave overview brochure - 3

STATIM 7000 – The chamber alternative STATIM 7000 benets: 12 minute unwrapped cycle • 15 minute wrapped cycle • 12 minute Dri-TecS drying Technology • Operates on tap water • Sterilizes up to 10 pouched packages • Holds two 8” x 11” instrument management cassettes • RFID seal technology • Easy serviceability • Removable water reservoir • Choice of external printer or datalogger • BRAVO – Faster, wrapped and dried BRAVO™ benets: Fast cycle times Fractionated vacuum system • Dri-TecV technology with closed door drying for a perfectly dry load every time • Single use distilled water • Pull’n...

Open the catalog to page 3
SciCan autoclave overview brochure - 4

Cycle Unwrapped Wrapped Rubber/Plastic Sterilization time Sterilization Temp Total Cycle time* Sterilization time Sterilization Temp Total Cycle time* Sterilization time Sterilization Temp Total Cycle time* Heavy Duty Unwrapped / Air Drying Air drying only Air drying only Air drying only Air drying only Air drying only Air drying only Sterilization time Sterilization Temp Total Cycle time* Total Cycle time including drying G Porous/Hollow ‡ Hollow ‡ Solid Solid Wrapped Unwrapped Wrapped Unwrapped Cycle time is dependent on instrument load * G ‡ Cycle times represent 220V units. Cycle times...

Open the catalog to page 4

All SciCan GmbH catalogs and technical brochures

  1. StatClean

    1 Pages

  2. OPTIM 1

    2 Pages

  3. OPTIM 28

    1 Pages

  4. OPTIM 33TB

    2 Pages

  5. SANAO ?

    6 Pages

  6. aquastat

    2 Pages

  7. STATIM

    8 Pages

Archived catalogs