HMTS Plasma Sterilizer
The HMTS system utilizes hydrogen peroxide and low-temperature gas plasma technology to sterilize heat and moisture-sensitive medical devices, including endoscopes. Key features include a rapid cycle time of 35 minutes, easy installation without special ventilation, and environmentally friendly operation producing only water vapor and oxygen. It is economical with a lower cost per cycle and offers a two-year warranty.
HAWO Rotary Heat Sealers
These sealers are crucial for maintaining sterility of medical instruments through packaging. They feature continuous monitoring of critical parameters and a touch-screen interface for easy navigation. The system complies with ISO 11607 Part 2, ensuring quality sealing without channels or punctures.
INNOVA E4 Pass-Through AER
Designed for Central Service Departments, the Innova E4 features two doors for clean and dirty sides, ensuring no cross-contamination. It processes two flexible endoscopes per cycle in about 50 minutes using Thermosept detergents and disinfectants, ensuring effective washing and disinfection.
Endotechnik Scope Porter
This device facilitates the transport and short-term storage of endoscopes, reducing contamination risk. It is easy to handle and maneuver, with large casters and a sturdy construction, making it suitable for narrow spaces.
AT-OS Bedpan Washer-Disinfector
This machine addresses infection transmission by ensuring thorough cleaning and disinfection of containers. It features automatic door operation and calculates the disinfection value A0 for each cycle, displaying the value at the end.
AT-OS Scope Cabinet
The Endocab 900 is made of stainless steel and holds 12 endoscopes. It features a pass-through design and active ventilation, ensuring secure and efficient storage.
BRAVO Chamber Autoclave
The Bravo autoclave uses a fractionated vacuum system for effective steam penetration and drying. It offers fast cycle times, a single-button operation, and conforms to international standards.
STATIM Cassette Autoclave
Known for its speed, the STATIM autoclave offers rapid sterilization cycles and features like Dri-Tec drying technology and a removable chamber for aseptic transfer. It is available in various models to accommodate different needs.
See more

Catalog excerpts

ENDOSCOPY AND CENTRAL SERVICE PRODUCT GUIDE-1

ENDOSCOPY AND CENTRAL SERVICE PRODUCT GUIDE

 Open the catalog to page 1
ENDOSCOPY AND CENTRAL SERVICE PRODUCT GUIDE-2

Endoscopy And Central Service Product Guide

 Open the catalog to page 2
ENDOSCOPY AND CENTRAL SERVICE PRODUCT GUIDE-3

ENDOSCOPY AND CENTRAL SERVICE PRODUCT GUIDE TABLE OF CONTENTS HMTS Plasma Sterilizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 HAWO Rotary Heat Sealers Endotechnik Scope Porter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 AT-OS Bedpan Washer-Disinfector AT-OS Scope Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 BRAVO Chamber Autoclave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 STATIM Cassette Autoclave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Your...

 Open the catalog to page 3
ENDOSCOPY AND CENTRAL SERVICE PRODUCT GUIDE-4

Endoscopy And Central Service Product Guide HAWO HMTS PLASMA STERILIZER The ster with the process guarante and for m The HMTS system uses hydrogen peroxide and low-temperature gas plasma technology to sterilize heat and moisture sensitive medical devices, such as rigid and flexible endoscopes. • Continu contact • For info a micro a one-li FEATURES & BENEFITS The HMTS system offers advantages over other low temperatur e systems: • Rapid cycle as fast as 35 minutes, even for flexible endoscopes • Easy to install: – does not require special ventilation or aeration – requires only electricity; no...

 Open the catalog to page 4
ENDOSCOPY AND CENTRAL SERVICE PRODUCT GUIDE-5

HAWO ROTARY HEAT SEALERS hm 3010 / 3020 DC-V / DC-VI / and hm 850DC-V The sterilization of medical instruments begins with the packaging. That is to say, the packaging process and its validation are crucial for guaranteeing sterility up to the point of use, and for meeting quality standards. • Continuous monitoring of the critical pr ocess parameters of temperature, contact pressure and sealing speed. • The touch-screen of the hm 3010-3020 makes menu navigation and data input particularly simple. • For information which must be printed on the packaging a microprocessor controlled printer is available...

 Open the catalog to page 5
ENDOSCOPY AND CENTRAL SERVICE PRODUCT GUIDE-6

Endoscopy And Central Service Product Guide The Innova E4 is designed for use in Central Service Departments. It has two doors, one on the “clean” side and one on the “dirty” side. Endoscopes ar e loaded on the dirty side, where the control panel is located and removed on the clean side, wher e the printer is located. The Innova E4’s software ensures that the user cannot open both doors at the same time. The Innova E4 insert accepts two flexible, immersible endoscopes and completes a cycle in about 50 minutes. The standar d chemicals for use with the E4 ar e 30 litre containers of Thermosept...

 Open the catalog to page 6
ENDOSCOPY AND CENTRAL SERVICE PRODUCT GUIDE-7

ENDOTECHNIK SCOPE PORTER The Scope Porter facilitates the transport and the short-term storage of used and/or disinfected flexible endoscopes and their accessories. The coloured plastic covers indicate the state of the transported device. Scope transport systems are increasingly common in hospitals because of the advantages they offer to an Endoscopy Department. The Scope Porter has been designed with modern Endoscopy Departments in mind. FEATURES & BENEFITS • purpose-built with large basins for transporting endoscopes • easily maneuverable, even when fully loaded • reduces risk of contamination...

 Open the catalog to page 7
ENDOSCOPY AND CENTRAL SERVICE PRODUCT GUIDE-8

Endoscopy And Central Service Product Guide AT-OS BEDPAN WASHER-DISINFECTOR One of the biggest problems which has to be eliminated in the hospitals is the transmission of infections from one patient to another due to badly cleaned containers. The contamination risk for both the user and patient is virtually eliminated thanks to the automatic door closure system, automatic emptying of the containers and superior cleaning and disinfection of the containers. A security system ensures that the door remains closed during the disinfection phase avoiding premature opening of the door and possible cross-contamination....

 Open the catalog to page 8
ENDOSCOPY AND CENTRAL SERVICE PRODUCT GUIDE-9

AT-OS SCOPE CABINET Endocab 900 – Cabinet for Endoscopes Made entirely of AISI 304 stainless st eel with Scotch Brite brushed finish and will hold a total of 12 endoscopes. • Three sandwich panels running on pull-out slides • Endoscope hook with lock system • Pass-through design and active ventilation systems also available ening of door if ur hands full. tomatic or opening d closing.

 Open the catalog to page 9
ENDOSCOPY AND CENTRAL SERVICE PRODUCT GUIDE-10

Endoscopy And Central Service Product Guide BRAVO™ chamber autoclave STATI autoc The Bravo is a fractionated vacuum sterilizer that incorporates both pre-vac (to remove air) and post-vac (to help drying) cycles to ensur e perfect steam penetration for any load. FEATURES & BENEFITS • Fast cycle times • Fractionated vacuum system • Closed door drying with Dri-TecV technology • Single use Pull’n Push water system • Easy to use – single button operation Your Infection Control Specialist • Conforms to international and national standards • Integrated printer option • Patented door locking mechanism...

 Open the catalog to page 10
ENDOSCOPY AND CENTRAL SERVICE PRODUCT GUIDE-11

STATIM® Cassette autoclave STATIM Sterilizers One of the fastest autoclaves in the world! from start to sterile. FEATURES & BENEFITS • 14 minute wrapped cycle • 17.5 minute wrapped cycle • 15 minute wrapped cycle • Exceptional instrument turnover • Rapid high volume throughput sterilization • 12 minute Dri-TecS drying technology • 10 minute Dri-TecC drying technology • Single use water • Fully removable chamber for aseptic transfer of instruments • Reduced instrument investment • 15 minute Dri-TecR drying technology • Single water use • Fully removable chamber for aseptic transfer of instruments...

 Open the catalog to page 11
ENDOSCOPY AND CENTRAL SERVICE PRODUCT GUIDE-12

SciCan Ltd. 1440 Don Mills Road Toronto, Ontario M3B 3P9 Local number: 416.445.1600 Toll free number: 1.800.667.7733 Fax: 416.445.2727 www.scican.com STATIM is a registered trademark of SciCan Ltd. Bravo, Dri-Tec logos and “Your Infection Control Specialist” are trademarks of SciCan Ltd. INNOVA is a registered trademark of SciCan GmbH, used by SciCan Ltd. under license. SD-349 09/10