HPLC COLUMNS Micro LC and cHiPLC columns HPLC COLUMNS
Open the catalog to page 1
Eksigent chromatography stationary phases Column Particle size Pore Sizes C18 bonded phase C8 bonded phase General chromatography, separation of hydrophobic compounds, separation of biomolecules such as proteins and peptides. Separation of large biomolecules like proteins and peptides, both in RP and HIC-mode, excellent stability at pH 1. C18 embedded polar C8 embedded polar Enhanced polar selectivity and excellent peak shape for acids and bases, wide range of pH, analysis of strong basic compounds in neutral pH. Phenyl RP, fully end-capped Alternate enhanced selectivity and hydrophobicity...
Open the catalog to page 2
High performance and high throughput Eksigent’s microLC and cHiPLC columns are designed to provide robust analytical performance in an easy-to-use format. Eksigent microLC columns are available in 0.3, 0.5 and 1.0 mm inner diameters (ID), and lengths of 3, 5, 10 and 15 cm. The columns can be used at pressures up to 10,000 psi, and have 1/32” end-fittings specifically designed to prevent dispersion at flow rates as low as 3 µL/min. Eksigent cHiPLC columns are a unique line of microfluidic chip based columns and traps in 75 μm and 200 μm ID, and lengths of 5 and 15 cm, with the possibility of...
Open the catalog to page 3
Flexible formats Micro cHiPLC columns Nano cHiPLC columns Performance of columns Eksigent columns complement the performance, ease of use, and reliability of the ekspert™ microLC 200 and ekspert nanoLC 400 systems. Packed using a process that provides long-term stability, eksigent columns ensure optimum separation, and allow you to realize the full potential of your instrument. nano cHiPLC column Relative Abundance conventional nanoLC column Micro LC columns maintain column efficiency at smaller IDs and provide excellent Comparison of the separation of a peptide test mix on a nano cHiPLC...
Open the catalog to page 4
MicroLC column robustness abs, mAU 2,200 injections with no degradation A: water, B: acetonitrile 5–98% B in 60 sec; 10 µL/min Injection volume: 40 nL Diethyl Phthalate Propyl Paraben Retention Times injection number After 2200 injections, retention time and column back pressure were unchanged. Retention Time RSDs 0.2-0.3% Choice of columns for different molecule classes Whether you are performing conventional or ultra-fast chromatography, separating biomolecules, or analyzing complex basic compounds, Eksigent has a diverse range of stationary phases that meet your needs. Small molecule...
Open the catalog to page 5
Your success is our success We take it personally As a customer of Eksigent, part of AB SCIEX, you have access to a world-class customer support organization. Wherever you are, we’re there with you as a trusted partner to answer questions, provide solutions, and maximize lab productivity. Our service engineers have the experience and expertise to help you get the most from your Eksigent UHPLC systems. Whether you’re looking to improve sensitivity, resolution, speed, or throughput, they can direct you to the right solution. When you have questions, we have answers. For more information,...
Open the catalog to page 6All SCIEX catalogs and technical brochures
-
SelexION
8 Pages
-
SCIEX VISION
32 Pages
-
MPX™
13 Pages
-
NanoLC™ 400
8 Pages
-
API 3200™ LC-MS/MS SYSTEM
8 Pages
-
3200MD
8 Pages
-
MicroLC 200 Plus
6 Pages
-
SelexION™
26 Pages
-
x500R
8 Pages
-
SCIEX TRIPLE QUAD™ 5500 SYSTEM
12 Pages
-
ExionLC 100 Extended Specs
2 Pages
-
PA 800 plus Catalog
16 Pages
-
Eksigent Ultra LC Systems
6 Pages
-
Ekspert NanoLC 400
7 Pages
-
ProteinPilot Software
6 Pages
-
MultiQuant Software
6 Pages
-
MetabolitePilot Software
6 Pages
-
AB SCIEX TripleTOF® 5600+ System
12 Pages
-
Brochure: Targeted Protein Quant
12 Pages
-
Brochure: Discovery Proteomics
12 Pages
-
Brochure: AB SCIEX TOF/TOF? 5800
12 Pages