CytoBrite® PLUS Slide IncubaƟon System
1Pages

{{requestButtons}}

Catalog excerpts

CytoBrite® PLUS Slide IncubaƟon System - 1

SciGene aoaeooaoeoe SIMPLIFYING FISH CytoBrite® PLUS Slide Incubation System Only FISH Hybridizer Compliant with New CAP Regulation CYG.33950* PRODUCT SNAPSHOT Programmable FISH hybridizer with temperature verification of each slide position — now required by CAP regulation CYG.33950. Each of the 12 slide positions is equipped with a separate temperature sensor. Simply connect the provided digital thermometer to view each position temperature. CytoBrite® PLUS uses PCR technology to quickly heat and cool slides with time and temperature recorded to a USB drive. Removable 6-slide trays streamline handling. Use with CytoBond® Coverslip Sealant that removes easily in one piece without humidification or substitute rubber cement with the use of humidity strips. *CYG.33950 ISH Slide Processing Temperature Checks System Highlights: • Individual sensors monitor every slide position • Verify each slide reaches temperature • PCR technology quickly heats and cools slides • Slide trays streamline handling • Time and temperature recorded to USB • NIST-certified thermometer included Product Catalog # CytoBrite PLUS Slide Incubation System, 115/230V. 2019-50-1 Companion Instrument CytoBrite Slide Oven, 115V. Holds 60 slides for overnight incubation. 2019-70-1 CytoBrite Slide Oven, 230V. Holds 60 slides for overnight incubation. 2019-70-2 Accessories Additional CytoBrite 6-slide tray. 2019-10-0 CytoBond Removable Coverslip Sealant, 100 ml. 2020-00-1 Connect provided thermometer to verify temperature of each slide. Specification Equipment Included Electrical Cat # 2019-00-1 Dimensions (HxWxD) Instrument Weight Performance Temperature range: Temperature regulation: Temperature accuracy: Temperature uniformity: Heating rate: Cooling rate: Description Instrument with 2x slide trays and a handheld NIST-certified digital thermometer. 115/230V AC, 50/60Hz, 6A/3A 8.25 x 9.5 x 16.5 inches (21 x24x42 cm) 21 lbs (9.5 kg) net 15 to 90°C ± 0.2°C ± 0.5°C ± 1.0°C 37 to 75°C in < 2 minutes 75 to 37°C in < 2 minutes CytoBond® Sealant removes in one piece without humidification. CytoBrite PLUS Temperatures Using Built-in Slide Sensors Slide positions: 37°C to 75°Cfor 4 min then back to 37°C Allowable range Time (min) SciGene • 1287 Reamwood Avenue, Sunnyvale, CA 94089 USA • Tel 408-733-7337 • Fax 408-733-7336 • sales@scigene.com

Open the catalog to page 1

All SciGene catalogs and technical brochures