DreamStar Duo DuoST
2Pages

{{requestButtons}}

Catalog excerpts

DreamStar Duo DuoST - 1

ORDERING INFORMATIONS Mode of operation : Bi-level, constant pressure Pressure ouput : EPAP : from 3 cm H20 to IPAP or 20 cm H20 (+/-0.5 cm H₂O) IPAP : from EPAP or 3 cm H20 to 25 cm H20 (+/-0.5 cm H₂O) Comfort pressure : from 3 cm H20 to EPAP DreamStar™ Duo Evolve w/reservoir Ramp duration : 0 to 45 minutes adjustable by 5 minutes DreamStar™ DuoST (includes patient circuit 1,8 m and carrying case) Advanced setting parameters : ISENS & ESENS : from 1 to 10 Pressure Rise Time : from 1 to 5 Back-up rate (DuoST) : from 0 to 25 bpm I/E ratio (DuoST) : from ¼ to 1/0.5 (includes patient circuit 1,8 m and carrying case) DreamStar™ Duo Evolve w/ cover (includes patient circuit 1,8 m and carrying case) DreamStar™ DuoST & DuoST Evolve (includes patient circuit 1,8 m and carrying case) DreamStar™ DuoST Evolve w/reservoir (includes patient circuit 1,8 m and carrying case) DreamStar™ DuoST Evolve w/ cover (includes patient circuit 1,8 m and carrying case) Bi-Level Devices Max. flow for 1 cmH2O pressure drop at the patient output : 180 lpm at 20 cmH2O without humidifier DreamStar™ Water Reservoir Noise level (with reservoir): 27 dB measured with an uncertainty of 2 dB according to ISO 17510-1:2002 DreamStar™ Cover 100 High efficiency air filter (27x42) Carrying case DreamStar™ Physical Characteristics : Power cord 2 poles - UK Size : 20 cm wide X 23 cm deep X 12 cm high Cigarette lighter cable 3A Weight : 1,5 kg with humidifier; 1,4 kg without humidifier Battery cable 3A ring term Filter : Cleanable standard or disposable HEPA Patient circuit 1,80 m / diam 15mm Power characteristics : Patient circuit 1,80 m / diam 22mm Power supply : Input range 100-240 V, 50-60 Hz Patient manual DreamStar™ Duo / DuoST Power supply on battery : 13 V Practitioner manual DreamStar™ Duo / DuoST Evolve CONFIGURATIONS The DreamStar™ Duo & DreamStar™ DuoST have a configuration without humidifier and the DreamStar™ Duo & DreamStar™ DuoST Evolve with an integrated heated humidifier. The Evolve configurations may be used either with a water reservoir for humidification or without humidification by replacing the water reservoir with a cover. Humidifier chamber capacity : 300 ml at the maximum water level Heater adjustable range and wattage : 0 to 10 adjustable (40 Watts at setting 10) Power consumption : 50 VA max without humidifier; 90 VA with humidifier at setting 10 (includes base, cover and gasket) Data Management : DreamStar™ Analyze software IEC 60601-1 classification : Class II (double isolation) Type BF DreamStar™ Analyze clinical kit Environmental requirements : Memory card DreamStar™ Operating temperature 5°C to 35°C, 10% to 95% relative humidity (RH), non-condensing Memory card reader Both DreamStar™ Duo & DuoST detect residual apneas and hypopneas, provide the estimated tidal volume and the leak level to easily evaluate the effectiveness of User manual The very latest innovations of the DreamStar™ Duo & DreamStar™ DuoST support optimum function of these devices used for non-invasive ventilation of patients suffering from Sleep Apnea Syndrome or respiratory failure but who are not dependant on ventilatory assistance. These technological innovations are designed to maximize comfort and patient compliance with the therapy allowing an easy treatment adaptation and follow up. Storage temperature : -20°C to 60°C, relative humidity (RH) ≤95%, non-condensing Quick and simple setting of the humidifier from the main screen of the device. Operating altitude : from sea level to 2700 meters For more information contact us at the following addresses : customerservice@sefam-medical.com marketing@sefam-medical.com DreamStar™ is a trademark of SEFAM Manufacturing plant, 10 allée Pelletier Doisy - 54600 VILLERS-LES-NANCY - FRANCE Legal entity, 144 avenue Charles de Gaulle - 92200 NEUILLY sur SEINE - FRANCE DreamStar™ DuoST Evolve w/ water reservoir

Open the catalog to page 1
DreamStar Duo DuoST - 2

Bi-Level Device DreamStar™ Duo & Duo Evolve DreamStar™ DuoST & DuoST Evolve The AUTO ON function enables patients to begin their treatment by simply breathing into their mask. They still have the option of activating the device by pressing the on/off button. Specific AUTO-CALIBRATION function ensures that the prescribed pressure is delivered at the patient’s interface. This makes the device compatible with almost any combination of mask and patient circuit of 22mm or 15mm diameter. COMPLIANCE DATA Management Compliance data are stored for 365 days in the internal memory of the device. The...

Open the catalog to page 2

All SEFAM catalogs and technical brochures