SPECIFICATIONS ORDERING INFORMATION Characteristics Products and accessories Reference Pressure output : 4 cm H20 to 20 cm H20 (+/- 0,5 cm H2O) DreamStar Info M-115501– UK Max. flow for 1cmH2O pressure drop at the patient output : 200 lpm at 20 cmH2O without humidifier Noise level : <26 dB measured with an uncertainty of 2 dB according to ISO 17510-1:2002 (includes patient circuit 1,8 m and carrying case) DreamStar Info Evolve w/ reservoir DreamStar Info Evolve w/ cover DreamStar Auto Ramp duration : 0 to 45 minutes adjustable by 5 minutes DreamStar Auto Evolve w/ reservoir Humidifier chamber capacity : 300 ml at the maximum water level M-115502– UK M-115522– UK (includes patient circuit 1,8 m and carrying case) DreamStar Auto Evolve w/ cover M-115512– UK (includes patient circuit 1,8 m and carrying case) Weight : 1,5 kg with humidifier; 1,4 kg without humidifier Filter : Cleanable standard or disposable HEPA Power characteristics Power supply : Input range 100-240 V, 50-60 Hz Power supply on battery : 13 V Power consumption : 50 VA max without humidifier; 90 VA with humidifier at setting 10 IEC 60601-1 classification : Class II (double isolation) Type BF Environmental requirements Operating temperature 5°C to 35°C, 10% to 95% relative humidity (RH), non-condensing M-315510-14 Filter holder kit (27x42) M-314820-02 96 Inlet Air filter (27x42) M-414840-06 100 High efficiency air filter (27x42) M-414841-07 M-815505-00 Power cord 2 poles - UK M-660601-40 M-214530-01 Battery cable 3A ring term M-214530-00 Patient circuit 1,80 m / diam 22mm M-261000-04 Patient manual DreamStar Info, Intro, Auto M-155DFU00-00 Practitioner manual DreamStar Info, Intro, AutoEvolve Continuous Positive Pressure Auto CPAP M-315530-19 Cigarette lighter cable 3A Size : 20 cm wide X 23 cm deep X 12 cm high DreamStar Water Reservoir (includes base, cover and gasket) Carrying case DreamStar Physical Characteristics DreamStar™ Auto & Auto Evolve (includes patient circuit 1,8 m and carrying case) DreamStar Cover Heater adjustable range and wattage : 0 to 10 adjustable (40 Watts at setting 10) DreamStar™ Info & Info Evolve M-115511– UK (includes patient circuit 1,8 m and carrying case) Mode of operation : DreamStar Info : Constant pressure DreamStar Auto : Constant pressure, Auto adjusting pressure Comfort pressure : 4 cm H20 to prescribed pressure M-115521– UK (includes patient circuit 1,8 m and carrying case) M-155DFU00-40 DreamStar™ Info & Auto are designed to maximize comfort and patient compliance with the therapy. The technological innovations allow an easy adaptation and follow up of the treatment. Both DreamStar™ Info & Auto detect apneas, hypopneas, inspiratory flow limitation and snoring. The differentiation between obstructive and central events and the leak level detection allow the clinician to evaluate the effectiveness of the therapy treatment. DreamStar™ Auto Data Management M-215630-00 DreamStar Analyze clinical kit M-215630-01 Memory card DreamStar M-215530-00 CONFIGURATIONS Memory card reader M-214830-03 User manual Storage temperature : -20°C to 60°C, relative humidity (RH) ≤95%, non-condensing DreamStar Analyze software M-156DFU00-20 The DreamStar™ Info & Auto have a configuration without humidifier and the DreamStar™ Info & Auto Evolve with an integrated heated humidifier. The Evolve configurations may be used either with a water reservoir for humidification or without humidification by replacing the water reservoir with a cover. Operating altitude : from sea level to 2700 meters For more information contact us at the following addresses : customerservice@sefam-medical.com marketing@sefam-medical.com DreamStar™ Auto Evolve w/ water reservoir DreamStar™ is a trademark of SEFAM Manufacturing plant, 10 allée Pelletier Doisy - 54600 VILLERS-LES-NANCY - FRANCE Legal entity, 144 avenue Charles de Gaulle - 92200 NEUILLY sur SEINE - FRANCE 0459 BRO031-03/ 2012

Open the catalog to page 1
DreamStar Info & Auto - 2

Continuous Positive Pressure Auto-CPAP DreamStar™ Info & Info Evolve DreamStar™ Auto & Auto Evolve Specific AUTO-CALIBRATION function ensures that the prescribed pressure is delivered at the patient’s interface. This makes the device compatible with almost any combination of mask and patient circuit of 22mm or 15mm diameter. COMPLIANCE DATA MANAGEMENT Compliance data are stored for 365 days in the internal memory of the device. The last 16 hours of the patient’s actual flow data provides in addition extra useful information about the effectiveness of the therapy. The DreamStar™ Analyze...

Open the catalog to page 2

All SEFAM catalogs and technical brochures