Triptique DreamStar
2Pages

{{requestButtons}}

Catalog excerpts

Triptique DreamStar - 1

Modes/ Algorithms DreamStarTM Intro Humid Control Comfort Calibration Plus (CC+) Humid Control Plus Data: Pressure & usage Data download : Data card Humidifier : Built in (Evolve version) Tubing : 22mm Altitude adjustment : Auto Analysis period : Last year, last month, manual selection or by download Data type : Night calendar, average pressure, usage information Last setting presentation Patient card and service card option Pressure range : 4-20 cm H2O Ramp time : 0-45 min Pressure Alter: ON/ OFF Humidification: 0-10 CC+: OFF, or during the ramp, or during treatment Data : Respiratory events (apnea, central apnea, hypopnea, central hypopnea, flow limitation, snoring), patient flow, summary and trends Data download : Data card, USB cable Humidifier : Built in (Evolve version) Ramp: Indexed (I), Time (T) Comfort mode : Comfort calibration plus (CC+) Tubing: 22mm, 15mm, custom calibration Altitude adjustment : Auto Analysis period : Last year, last month, manual selection or by download Data type : Night calendar, pressure, average pressure, usage information, respiratory events, AHI, pressure efficient for 90% of the time Graphs : Events vs pressure, leaks, measured pressure, pressure vs % time and patient flow Trends : Events, UA status, leaks and pressure History setting presentation Patient card and service card option Pressure range : 4-20 cm H2O Ramp time : 0-45 min Pressure adjustment : Pmin, Pmax , Pmax Apnea & IFL Humidification: 0-10 CC+: OFF, or during the ramp, or during treatment Data : Respiratory events (apnea, central apnea, hypopnea, central hypopnea, flow limitation, snoring), patient flow, summary and trends Data download : Data card, USB cable Humidifier : Built in (Evolve version) Ramp: Indexed (I), Time (T) Comfort mode : Comfort calibration plus (CC+) Tubing: 22mm, 15mm, custom calibration Altitude adjustment : Auto IPAP : 3-25 cm H2O EPAP : 3-20 cm H2O Ramp time : 0-45 min Rise time : 1-5 Isens, Esens : 1-10 Humidification : 0-10 ADAPT screen: help with adjustment of ventilation parameters Data : Respiratory events (apnea, hypopnea), patient flow, summary and trends Data download : Data card, USB cable Humidifier : Built in (Evolve version) Tubing: 22mm, 15mm, custom calibration Altitude adjustment : Auto Analysis period : Last year, last month, manual selection or by download Data type : Night calendar, average respiratory rate, usage information, respiratory events, AHI Graphs : Respiratory rate vs % time, leaks vs % time and patient flow Trends : Volume, leaks & respiratory rate History setting presentation Patient card and service card option ADAPT screen: help with adjustment of ventilation parameters Data : Respiratory events (apnea, hypopnea), patient flow, summary and trends Data download : Data card, USB cable Humidifier : Built in (Evolve version) Tubing: 22mm, 15mm, custom calibration Altitude adjustment : Auto Analysis period : Last year, last month, manual selection or by download Data type : Night calendar, average respiratory rate, usage information, respiratory events, AHI Graphs : Respiratory rate vs % time, leaks vs % time and patient flow Trends : Volume, leaks and respiratory rate & % spontaneous cycles History setting presentation Patient card and service card option Indexed Ramp DreamStar Info CPAP / Auto CPAP Auto CPAP Auto CPAP Algorithm Auto Calibration Comfort Calibration Plus (CC+) Humid Control Plus Auto ON DreamStarTM Auto Flow Sens Auto Calibration Humid Control Plus CPAP/ Bilevel ST Flow Sens Auto Calibration Humid Control Plus Auto ON TM Analysis period : Last year, last month, manual selection or by download Data type : Night calendar, average pressure, usage information, respiratory events, AHI, pressure efficient for 90% of the time Graphs : Events vs pressure, leaks, measured pressure, pressure vs % time and patient flow Trends : Events, UA status, leaks and pressure History setting presentation Patient card and service card option Obstructive Sleep Apnea Syndrome Obstructive Sleep Apnea Syndrome Obstructive Sleep Apnea Syndrome Indexed Ramp CPAP/ Bilevel Data Management Pressure range : 4-20 cm H2O Ramp time : 0-45 min Pressure Alter: ON/ OFF Humidification: 0-10 CPAP Auto Calibration IPAP : 3-25 cm H2O EPAP : 3-20 cm H2O Ramp time : 0-45 min Rise time : 1-5 Isens, Esens : 1-10 Backup rate : 0 or 4-25 bpm I/E ratio : 1/4 - 1/0.5 Humidification : 0-10 NIV Sleep Apnea syndrome Chronic Respiratory Insufficiency (for patient not dependent on ventilator assistance) NIV Sleep Apnea syndrome Chronic Respiratory Insufficiency (for patient not dependent on ventilator assistance)

Open the catalog to page 1
Triptique DreamStar - 2

DreamStar Analyze for Data management DreamStar Analyze is a user friendly and fully configurable software for the download, review of therapy data and the upload of new settings. The extended data visualisation and the easy display makes the evaluation of the data a quick, easy and up-to-the-point process. Synthesis report view for an quick & easy overview of the therapy · Usage · Pressure for CPAP · Events vs Pressure for CPAP · Respiratory rate for Bilevel · Respiratory Events, Indexes · Leaks · Settings Graph view for the review of the conditions in patient’s mask · Pressure for CPAP ·...

Open the catalog to page 2

All SEFAM catalogs and technical brochures