video corpo

HEMIX 5-60
3Pages

{{requestButtons}}

Catalog excerpts

HEMIX 5-60 - 1

TECHNICAL SPECIFICATIONS HEMIX 5-60: REFERENCE A0210 HEMIX 5-60 AUTOLOADER: REFERENCE A0211 MEASURING PRINCIPLES Laser light scatter technology for 5-part WBC differential Impedance method for CBC: WBC (80 μm), RBC and PLT (70 μm) Light absorbance for HGB measurement: cyanide-free method MEMORY STORAGE 100 000 records MEASURING PARAMETERS CBC+5 DIFF mode 26 parameters: WBC, LYM #&%, MON #&%, NEU #&%, EOS #&%, BAS #&%, RBC, HGB, HCT, MCV, RDW (sd/cv), MCH, MCHC, PLT, PCT, MPV, PDW (sd/cv), P-LCR, P-LCC; 2 histograms: RBC, PLT; 2 scattergrams: 4 diff, BASO INTERFACE Windows® 8.1 embedded Multilingual software Multiuser mode - Multilevel user modes with individual identification (username, password) Software upgrade - via USB port (USB memory stick) Reagents: 3 cyanide-free reagents - 1xDiluent, 2xLyse QUALITY CONTROL Separate QC database, unlimited number of QC files Levey-Jennings graphs OPERATING ENVIRONMENT Temperature 15°C – 35°C Relative humidity max 80% (non-condensing) POWER REQUIREMENTS A.C. 110/220 V ±10%; 50 – 60 Hz Input power 400 W DIMENSIONS 400(W) x 450(H) x 500(D) mm WEIGHT 35kg REAGENTS AND CONSUMABLES THROUGHPUT 60 tests per hour OPTIONAL AUTOSAMPLER Sample capacity -100 tubes: 10 racks with 10 sample tubes Acceptable primary tubes - Monovette, Vacutainer, Vacuette Built-in barcode reader Built-in sample mixer Cap recognition (only capped tubes are mixed and processed) Dimensions - 300 (W) x 300 (D) x 180 (H) mm Weight - 10kg DISPLAY User interface - 600 x 800 color graphics LCD, touch screen (10.4”) SFRI Diluent 5.1 REAGENTS Non contractual document. Specifications subject to change without notice. Ref. HEMIX560ENG-V201603 – Copyright © 2016 SFRI. All rights reserved REAGENTS AND SAMPLING SYSTEM Samples: Sample volume - 100 μl of whole blood Closed and open tube sampling, with optional autosampler Stat mode, specific control materials and calibration INPUT/OUTPUT External keyboard - PS/2 or USB RS232, USB, Ethernet Your Local Distributor: PRINTOUT External, Microsoft Windows® compatible printers SFRI SAS - Lieu-dit Berganton - 33127 Saint Jean d’Illac (Bordeaux) - FRANCE Tel. +33 (0)5 56 68 80 50 - Fax +33 (0)5 56 21 79 03 - contact@sfri.com - www.sfri.com

Open the catalog to page 1
HEMIX 5-60 - 2

Even SMALL labs get to have HIGH QUALITY results All-in-one Upgradable Instrument Excellent Accuracy Market reference blood cell counters are widely known on the market for the quality of their results but are very expensive, and are only used by big laboratories with high throughputs and budget. Conclusion: The lower the CV the more reliable the results. The test shows that the HEMIX 5-60 results are just as good as the results obtained on the reference analyzers. The HEMIX 5-60 even obtains the best CV on WBC. The HEMIX 5-60 results compete with big expensive analyzers from...

Open the catalog to page 2
HEMIX 5-60 - 3

HEMIX 5-60 AUTOLOADER: REFERENCE A0211 MEMORY STORAGE 100 000 records INPUT/OUTPUT External keyboard - PS/2 or USB RS232, USB, Ethernet MEASURING PRINCIPLES Laser light scatter technology for 5-part WBC differential Impedance method for CBC: WBC (80 pm), RBC and PLT (70 pm) Light absorbance for HGB measurement: cyanide-free method MEASURING PARAMETERS CBC+5 DIFF mode 26 parameters: WBC, LYM #&%, MON #&%, NEU #&%, EOS #&%, BAS #&%, RBC, HGB, HCT, MCV, RDW (sd/cv), MCH, MCHC, PLT, PCT, MPV, PDW (sd/cv), P-LCR, P-LCC; 2 histograms: RBC, PLT; 2 scattergrams: 4 diff, BASO REAGENTS AND SAMPLING...

Open the catalog to page 3

All SFRI catalogs and technical brochures

  1. HEMIX 3-60

    3 Pages

  2. IONIX

    3 Pages

  3. ISE SERIES

    3 Pages

  4. BSA 3000

    3 Pages

  5. ESR 3000

    3 Pages