GDTS-07 with Shockwave 3 in 1
1 / 41Pages

Catalog excerpts

GDTS-07 with Shockwave 3 in 1 - 1

Smar t Tecar Thrapy

Open the catalog to page 1
GDTS-07 with Shockwave 3 in 1 - 2

Parameters Model: Shock Wave Energy: Shock Wave Frequency Tecar Head Sizes: 10.4 inch touch screen Packing Dimention: Gross Weight:

Open the catalog to page 2
GDTS-07 with Shockwave 3 in 1 - 4

① T-shape Handle ② CET Handle ③ RET Handle ④ Return Pad ⑤ ⑥ ⑤ Shock Wave Handle ⑥ Ultrasound Ha

Open the catalog to page 4
GDTS-07 with Shockwave 3 in 1 - 5

Shock Wave Working Heads

Open the catalog to page 5
GDTS-07 with Shockwave 3 in 1 - 6

Optional handles for Tecar Therapy

Open the catalog to page 6
GDTS-07 with Shockwave 3 in 1 - 7

Shock Wave Therapy 1 Working principle and its functions Shockwave is an acoustic wave which carries high energy to painful spots and skeletal tissues with subacute, sub chronic and chronic conditions. The energy promotes regeneration and reparative processes of the bones, tendons and other soft tissues.

Open the catalog to page 7
GDTS-07 with Shockwave 3 in 1 - 8

Functions of Shockwave: In cell: enhances cell membrane permeability by increasing ion channel activity, promoting cell division, and stimulating cytokine production. In tendon and muscle blood vessels: improves blood circulation, increases biogenic factor β1, and enhances osteoblast mitosis. In nitrogen oxide system: accelerates bone remodeling and healing. Ø Ø Ø Ø Ø Improves microcirculation and metabolism Promotes the dissolution of calcified fibrocytes Promotes collagen synthesis Reduces tissue tension Alleviates p

Open the catalog to page 8
GDTS-07 with Shockwave 3 in 1 - 10

Ø Preload: 800-3000 impacts Ø Energy: 1 Bar-6 Bar Ø Frequency: 1 Hz- 21 Hz

Open the catalog to page 10
GDTS-07 with Shockwave 3 in 1 - 11

Click on “SHOCK WAVE”

Open the catalog to page 11
GDTS-07 with Shockwave 3 in 1 - 12

5 Apply gel to the treatment area 6 Target, press and then move it around or make a fixed-pointed operation Press “Start” button to wor

Open the catalog to page 12
GDTS-07 with Shockwave 3 in 1 - 13

Tips Ø The shockwave needs to work with gel. Ø Move the handle slightly according to the needs. Ø Click the screen and press the “Start” button of the handle to restart after the preload impacts are finished. Ø Use warm towel to clean working head after treatment. Ø Use the brush to clean the guiding tube of the

Open the catalog to page 13
GDTS-07 with Shockwave 3 in 1 - 14

Contradictions in Shock Wave Therapy Ø Vascular diseases present in or near the treatment area Ø Local infections in the treatment area Ø Around malignant or benign tumours Ø Directly on cartilage surfaces or near the small facet joints of the spinal column Ø Directly over implanted electronic devices such as pacemakers, analgesic pumps, etc. Ø In areas, in which mechanical energy in the form of vibrations may lead to tissue damage such as metal implants after a fract

Open the catalog to page 14
GDTS-07 with Shockwave 3 in 1 - 15

Working principle Tecar therapy is a part of Endogenous Thermotherapy, which is based on the principle of capacitive and resistive energy transfer (Capacitive-Resistive Diathermy). It has an effect within the biological tissues, activating the body’s natural repairing and anti-inflammatory processes from within.

Open the catalog to page 15
GDTS-07 with Shockwave 3 in 1 - 16

CET Ø Tissues with high water contents Ø Muscles, face... Ø Penetration depth: 3-4 cm RET Ø Tissues with the highest resistance and low water content Ø Bones, tendons, adipose tissues... Ø Penetration depth: 8-10

Open the catalog to page 16
GDTS-07 with Shockwave 3 in 1 - 18

Ø Time: 1-60 Mins Ø Energy: 10%-100% Ø Heat: Athermal, Medium Thermal, Deep Thermal, Auto

Open the catalog to page 18
GDTS-07 with Shockwave 3 in 1 - 20

Place the return pad under the thign or calf and target to the treatment area with RF crea

Open the catalog to page 20
GDTS-07 with Shockwave 3 in 1 - 22

Treatment area Treatment time Postpartum recovery Caudal vertebra Shoulder joint

Open the catalog to page 22
GDTS-07 with Shockwave 3 in 1 - 23

Treatment area Working head Athermal:50% energy; fixed-point operation for 5-10 mins. Medium Thermal: 50% energy; move the handle slowly; 10 mins. Deep Thermal: 60% energy; move the handle quickly; 20 mins. Interval: twice a week Sessions: 6 times Athermal:50% energy; fixed-point operation for 5-10 mins. Medium Thermal: 50% energy; move the handle slowly; 10 mins. Deep Thermal: 40% energy; move the handle quickly; 20 mins. Interval: twice a week Sessions: 8 times Athermal:50% ener gy; f ixed- point operation for 5-10 mins. Medium Thermal: 50% energy; move the handle slowly; 10 mins. Deep...

Open the catalog to page 23
GDTS-07 with Shockwave 3 in 1 - 24

Treatment area Postpartum recovery Working head Athermal:50% energy; fixed-point operation for 5-10 mins. Medium Thermal: 50% energy; move the handle slowly; 10 mins. Deep Thermal: 70% energy; move the handle quickly; 25 mins. Interval: twice a week Sessions: 12 times Athermal:50% energy; fixed-point operation for 5-10 mins. Medium Thermal: 50% energy; move the handle slowly; 10 mins. Deep Thermal: 70% energy; move the handle quickly; 25 mins. Interval: twice a week Sessions: 8 times Athermal:50% ener gy; f ixed- point operation for 5-10 mins. Medium Thermal: 50% energy; move the handle...

Open the catalog to page 24
GDTS-07 with Shockwave 3 in 1 - 25

Treatment area Caudal vertebra Working head T-RES handle T-RES handle T-RES handle T-RES handle Athermal:50% energy; fixed-point operation for 5-10 mins. Medium Thermal: 60% energy; move the handle slowly; 10 mins. Deep Thermal: 70% energy; move the handle quickly; 20 mins. Interval: twice a week Sessions: 12 times Athermal:50% energy; fixed-point operation for 5-10 mins. Medium Thermal: 60% energy; move the handle slowly; 10 mins. Deep Thermal: 70% energy; move the handle quickly; 20 mins. Interval: twice a week Sessions: 8 times Athermal:30% ener gy; f ixed- point operation for 5-10 mins....

Open the catalog to page 25
GDTS-07 with Shockwave 3 in 1 - 26

Treatment area Shoulder joint Knee joint Working head Athermal:50% energy; fixed-point operation for 5-10 mins. Medium Thermal: 50% energy; move the handle slowly; 10 mins. Deep Thermal: 60% energy; move the handle quickly; 20 mins Interval: twice a week Sessions: 8 times. Athermal:70% energy; fixed-point operation for 5-10 mins. Medium Thermal: 60% energy; move the handle slowly; 10 mins. Deep Thermal: 70% energy; move the handle quickly; 20 mins. Interval: twice a week Sessions: 10 times Athermal:40% ener gy; f ixed- point operation for 5-10 mins. Medium Thermal: 70% energy; move the...

Open the catalog to page 26
GDTS-07 with Shockwave 3 in 1 - 27

Treatment area Acupuncture point Athermal:60% energy; fixed-point operation for 5-10 mins. Medium Thermal: 60% energy; move the handle slowly; 10 mins. Deep Thermal: 60% energy; move the handle quickly; 20 mins Interval: twice a week Sessions: 12 times. Athermal:60% energy; fixed-point operation for 5-10 mins. Medium Thermal: 60% energy; move the handle slowly; 10 mins. Deep Thermal: 60% energy; move the handle quickly; 20 mins. Interval: twice a week Sessions: 8 times Athermal:50% ener gy; f ix ed- point operation for 5-10 mins. Medium Thermal: 50% energy; move the handle slowly; 10 mins....

Open the catalog to page 27

All Shanghai Goodmed Medical Device catalogs and technical brochures

  1. AIR902

    1 Pages

  2. XY-K-JLC-D

    3 Pages

  3. S610

    2 Pages

  4. S400

    2 Pages

  5. S110

    1 Pages

  6. OM-A-II ECP

    1 Pages

  7. OM-A ECP

    4 Pages

  8. GD-FA

    9 Pages

  9. HB102

    1 Pages

  10. HB101

    1 Pages

  11. HB100

    1 Pages

  12. HB-400W

    1 Pages

  13. HB-200W

    1 Pages

  14. AMT-B

    24 Pages

  15. RTM06

    2 Pages

  16. RTM05

    2 Pages

  17. RTM04

    2 Pages

  18. RTM03

    2 Pages

  19. RTM02

    2 Pages

  20. HB510B rtms

    7 Pages

  21. Smart Tecar

    9 Pages

  22. WB003

    84 Pages

  23. SWT300

    2 Pages

  24. Ruilex

    1 Pages

  25. XY-CJB-II

    6 Pages

  26. HBY-FL15

    9 Pages

  27. HBY-FL20

    9 Pages

  28. 4500U1

    9 Pages

  29. S720

    1 Pages

  30. S530

    1 Pages

  31. S500

    1 Pages

  32. WB-W-E

    6 Pages

  33. AMT-C

    24 Pages

  34. HB-200C

    1 Pages

  35. TMS

    14 Pages

  36. MAGREX-A

    2 Pages

  37. PMST-3

    5 Pages

  38. R02

    13 Pages

  39. RTM01

    2 Pages

  40. TDCS-02

    18 Pages

  41. ZP4

    1 Pages

  42. SJ1

    1 Pages

  43. HB520B rtms

    7 Pages

  44. RT1100

    14 Pages