Overview of TENS: Transcutaneous Electrical Nerve Stimulation (TENS) is a non-invasive method developed in the 1970s based on the pain gate control theory. It uses low-frequency pulse currents to treat pain by stimulating nerve and muscle cells, promoting the production of morphine-like substances in the body, and blocking pain signals. TENS is widely used in Europe and America for pain management and tissue regeneration.
Clinical Applications: TENS is effective for various types of pain, including cervical pain, ligament injuries, chronic and acute pain, phantom pain, postoperative pain, dysmenorrhea, labor pain, migraines, neuralgia, and joint pain. It is also used in electroacupuncture and electric massage to stimulate tissue regeneration and enzyme activity.
Indications and Scope: TENS is suitable for treating acute and chronic pain and is applicable in fields such as orthopedics, rehabilitation, neurology, dermatology, stomatology, ENT, and gynecology.
Contraindications: TENS should not be used in cases of tetanus, bleeding tendencies, tuberculosis, thrombophlebitis, amyotrophic lateral sclerosis, multiple sclerosis progression, or in areas with a pacemaker, metal implants, or malignant tumors. It is also contraindicated for pregnant women's lower abdomen and acute purulent inflammation.
Device Specifications: The TENS device consists of a host, power cord, electrode wire, and electrode sheet. Different models are available, and the device uses a microcomputer control chip to generate low-frequency pulse currents.
Electrode Placement: Electrodes should be placed at trigger points, acupuncture points, or near the pain area. Placement methods include juxtaposition, opposite, proximal-distal juxtaposition, and crossover for larger surface areas.
Treatment Recommendations: Frequency selection is based on symptom relief, with chronic pain using 14-60Hz and postoperative pain using 50-150Hz. Current intensity should cause tremor without pain, generally 15-30mA. Treatment duration varies, with a typical course being 10 days, followed by a rest period.
Replaceable Parts: Replaceable parts include the electrode wire, electrode sheet, and power cord, which should be sourced from the original manufacturer to ensure device stability.
See more

Catalog excerpts

RT1100-1

Transcutaneous electrical nerve stimulator

 Open the catalog to page 1
RT1100-2

Transcutaneous Electrical Nerve Stimulation - TENS 2 Transcutaneous electrical nerve stimulator

 Open the catalog to page 2
RT1100-3

TENS therapy TENS therapy Transcutaneous Electrical Nerve Stimulation, or TENS for short, was developed in the 1970s according to the pain gate control theory. It is a non-invasive treatment method that injects specific low-frequency pulse currents into the human body through the skin to treat pain. After more than 20 years of development, TENS is very popular in European and American countries, and its clinical application has gone beyond the scope of pain, but it still focuses on the treatment of pain. Become the most basic way to solve pain without taking medicine and without injections. How...

 Open the catalog to page 3
RT1100-4

TENS therapy Clinical application Treatment of various acute and chronic pain Analgesic effect - Cervical pain - Ligament injury - Chronic pain - Acute sprain - Phantom pain - Limb stump pain - Postoperative incision pain - Dysmenorrhea - Labor pain - Migraine - Neuralgia - Joint pain Electroacupuncture electric massage stimulate tissue regeneration effect on acupuncture points Promote the activity of enzymes Indications: It is suitable for the treatment of acute and chronic pain relief; it can also be used for the common pain treatment of electroacupuncture and electro-massage. Scope of application:...

 Open the catalog to page 4
RT1100-5

TENS therapy Contraindications & Feature Do not treat if: tetanus bleeding tendency tuberculosis foci thrombophlebitis amyotrophic lateral sclerosis Pathological progression of multiple sclerosis Do not treat the following areas: local heart local carotid sinus local malignant tumor local pacemaker Partial metal built-in pregnant woman lower abdomen acute purulent inflammation Feature: No damage Pain free No risk of infection Short treatment time No side effects and complications Adapt to a wide range.

 Open the catalog to page 5
RT1100-6

Transcutaneous electrical nerve stimulator Transcutaneous electrical nerve stimulator Transcutaneous electrical nerve stimulator (abbreviation: TENS) provides a reference oscillation signal by a microcomputer control chip, which is amplified by a power amplifier to drive the output of the output transformer. Through the output electrode line, through the skin electrode, the bidirectional asymmetric low-frequency pulse current is applied to the human body for auxiliary treatment.

 Open the catalog to page 6
RT1100-7

Transcutaneous electrical nerve stimulator Structure and composition Product structure and composition: It is composed of host, power cord, electrode wire and electrode sheet. Model difference:

 Open the catalog to page 7
RT1100-8

Transcutaneous electrical nerve stimulator Indications and contraindications Indications: It is suitable for the treatment of acute and chronic soft tissue pain relief. Contraindications: heart area; bleeding tendency; lower abdomen of pregnant women; thrombophlebitis; Part of metal built-in; Local acute purulent inflammation; People with caution: patients with metal implants; malignant tumor patients; pregnant woman; open wounds; Vascular embolism; Low white blood cells. tetanus; tuberculosis foci; Local malignant tumor; Pacemaker local; amyotrophic lateral sclerosis; Pathological progression...

 Open the catalog to page 8
RT1100-9

Transcutaneous electrical nerve stimulator

 Open the catalog to page 9
RT1100-10

Transcutaneous electrical nerve stimulator

 Open the catalog to page 10
RT1100-11

Transcutaneous electrical nerve stimulator Treatment with electrode pads   Electrode placement method Crossover method for larger surface area 1) Place at special points, namely trigger points, acupuncture points and exercise points. These points have low skin resistance and high density input to the central nervous system. is an effective site for placing electrodes 2) Place it next to the pain area, exercise point, trigger point, acupuncture point, and the same segment of the spine as the lesion. Along the peripheral nerve, the segment above the lesion, and the same segment on the opposite...

 Open the catalog to page 11
RT1100-12

Transcutaneous electrical nerve stimulator Treatment with electrode pads  Electrode placement method 3) Place in the superior cervical ganglion (on both sides of the C2 transverse process under the mastoid) or pass current through the skull

 Open the catalog to page 12
RT1100-13

Transcutaneous electrical nerve stimulator Treatment with electrode pads Recommended prescription 【Treatment frequency】 The frequency selection is mostly based on the patient's feeling that the symptoms can be relieved. Chronic pain should use 14-60Hz; postoperative pain should use 50-150Hz; herpetic pain should use 15-160Hz; pain after peripheral nerve injury should use 30-120Hz, etc. It is generally advocated that the patient chooses the frequency that he considers appropriate. Most patients are suitable for stimulation frequency 100Hz, pulse width 100-300μs Recommended prescription 【Current...

 Open the catalog to page 13
RT1100-14

Transcutaneous electrical nerve stimulator Replaceable parts  The replaceable parts of this equipment are: electrode wire, electrode sheet, power cord, all parts should be replaced by Shenzhen Elite Medical Technology Co., Ltd.; using parts from other companies may cause the output of the instrument to be unstable.

 Open the catalog to page 14

All Shanghai Goodmed Medical Device catalogs and technical brochures

  1. AIR902

    1  Page

  2. TMS-X

    3  Pages

  3. S610

    2  Pages

  4. S400

    2  Pages

  5. S110

    1  Page

  6. OM-A-II ECP

    1  Page

  7. OM-A ECP

    4  Pages

  8. GD-FA

    9  Pages

  9. HB102

    1  Page

  10. HB101

    1  Page

  11. HB100

    1  Page

  12. HB-400W

    1  Page

  13. HB-200W

    1  Page

  14. AMT-B

    24  Pages

  15. RTM06

    2  Pages

  16. RTM05

    2  Pages

  17. RTM04

    2  Pages

  18. RTM03

    2  Pages

  19. RTM02

    2  Pages

  20. HB510B rtms

    7  Pages

  21. Smart Tecar

    9  Pages

  22. WB003

    84  Pages

  23. SWT300

    2  Pages

  24. Ruilex

    1  Page

  25. XY-CJB-II

    6  Pages

  26. HBY-FL15

    9  Pages

  27. HBY-FL20

    9  Pages

  28. 4500U1

    9  Pages

  29. S720

    1  Page

  30. S530

    1  Page

  31. S500

    1  Page

  32. WB-W-E

    6  Pages

  33. AMT-C

    24  Pages

  34. HB-200C

    1  Page

  35. TMS

    14  Pages

  36. MAGREX-A

    2  Pages

  37. PMST-3

    5  Pages

  38. R02

    13  Pages

  39. RTM01

    2  Pages

  40. TDCS-02

    18  Pages

  41. ZP4

    1  Page

  42. SJ1

    1  Page

  43. HB520B rtms

    7  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.