Smart Tecar Wave with Shockwave 3 in 1
1 / 22Pages

Catalog excerpts

Smart Tecar Wave with Shockwave 3 in 1 - 1

Smart Tecar Wave 3 IN 1 Multi-function machine >Tecar +Shockwave+EMS >EMS Hand Free Can Working Together >Electric Muscle Stimulation >Various body parts selec

Open the catalog to page 1
Smart Tecar Wave with Shockwave 3 in 1 - 2

TECHNICAL PARAMETER Model Smart Tecar Wave Shock Wave Energy Shockwave Frequency Heads Size

Open the catalog to page 2
Smart Tecar Wave with Shockwave 3 in 1 - 3

Tecar Interface  Real- time parameter display  3 optional patterns, the althermal, medium thermal and deep thermal  Various body par ts selections  Each par t with detailed treatment Recommended  Various handle options, each handle s

Open the catalog to page 3
Smart Tecar Wave with Shockwave 3 in 1 - 4

Electromagnetic shockwave SHOCKWAVE is aimed at the affected areas that are the source of chronic pain. The influence of the shockwaves causes to the dissolution of calcium deposits and leads to better vascularization. The after-effect is relief from the pain.

Open the catalog to page 4
Smart Tecar Wave with Shockwave 3 in 1 - 5

Shockwave for physiotherapy Shockwave is an acoustic wave which carries high energy to painful areas and soft tissues with subacute, subchronic and chronic conditions. This energy promotes healing, regenerating and reparative processes. It's a unique, non-invasive solution for pain associated with the musculoskeletal system. Just three to four treatments needed at weekly intervals. A therapy session only takes approximately 10 minutes.

Open the catalog to page 5
Smart Tecar Wave with Shockwave 3 in 1 - 6

ED Treatment Most men suffering from erectile dysfunction have vascular problems affecting the vessels that supply blood to the cavernous bodies of the penis, resulting in a decreased ability to develop and maintain an erection. The end result is an inadequate blood-flow followed by premature draining of an already reduced amount of blood from the cavernous bodies, meaning an erection is not achieved. Shockwave Therapy for ED of this type can be a highly effective treatment.

Open the catalog to page 6
Smart Tecar Wave with Shockwave 3 in 1 - 7

Body part Working head Frequency/ Energy Pain points Sessions Times Surrounding muscles Pain points Surrounding muscles

Open the catalog to page 7
Smart Tecar Wave with Shockwave 3 in 1 - 8

Body part Working head Frequency/ Energy Sessions 10HZ/100MJ Pain points Surrounding muscles 1HZ/50MJ Make 5 points with a fixed click, 300 times for each click Pain points Surrounding muscles interval of 3-7 days, three consecutive 2000-3000 weeks as a course of treatment, three weeks of rest, and the next course of treatment

Open the catalog to page 8
Smart Tecar Wave with Shockwave 3 in 1 - 9

Tecar : Capactive And Resistive Energy Transfer TECAR therapy as a system of Capacitive and Resistive electric transfer ,which is one of the methods used in diathermy, was devel oped as a form of deep thermotherapy ,delivers radiofrequency (RF) energy,which passes between active electrode and inactive electrode, and generates heat in the human body .

Open the catalog to page 9
Smart Tecar Wave with Shockwave 3 in 1 - 10

Tecar Effect T he h e a t s p e e d s up m e t a b o l i s m . T h i s causes blood to flow faster and to become more oxygenated. The result is that more oxygen, and other healing properties of your body’s natural systems, are rushed to the site. The waste is also removed more quickly. The overall result is that your pain is reduced significantly, and the injur y is healed more quickly

Open the catalog to page 10
Smart Tecar Wave with Shockwave 3 in 1 - 11

Tecar Optional Handle

Open the catalog to page 11
Smart Tecar Wave with Shockwave 3 in 1 - 12

Picture Treatment area Working head Athermal : 50 % energy; fixed-point operation for 510 mins. Medium Thermal: 50 % energy; move the handle slowly; 10 mins. Deep Thermal: 60 % e n e r g y ; move t he handle quickly; 20 mins. Interval: twice a week Sessions: 6 times Athermal : 50 % energy; fixed-point operation for 510 mins. Medium Thermal: 50 % e n e r g y ; move the handle slowly; 10 mins. Deep Thermal: 40 % e n e r g y ; move the handle quickly; 20 mins. Interval: twice a week Sessions: 8 times Athermal : 50 % energy; fixed-point operation for 510 mins. Medium Thermal: 50 % e n e r g y ;...

Open the catalog to page 12
Smart Tecar Wave with Shockwave 3 in 1 - 13

Picture Treatment area Postpartum recovery Working head Athermal : 50% energy; fixed-point operation for 510 mins. Medium Thermal: 50 % energy; move the handle slowly; 10 mins. Deep Thermal: 70 % energy; move the handle quickly; 25 mins. Interval: twice a week Sessions: 12 times Athermal:50% energy; fixed-point operation for 510 mins. Medium Thermal: 50 % energy; move the handle slowly; 10 mins. Deep Thermal: 70 % energy; move the handle quickly; 25 mins. Interval: twice a week Sessions: 8 times Athermal : 50% energy; fixed-point operation for 510 mins. Medium Thermal: 50 % energy; move the...

Open the catalog to page 13
Smart Tecar Wave with Shockwave 3 in 1 - 14

Picture Treatment area Caudal vertebra Working head T-RES handle T-RES handle T-RES handle T-RES handle Athermal:50% energy; fixed-point operation for 5-10 mins. Medium Thermal: 60% energy; move the handle slowly; 10 mins. Deep Thermal: 70% energy; move the handle quickly; 20 mins. Interval: twice a week Sessions: 12 times Athermal:50% energy; fixed-point operation for 5-10 mins. Medium Thermal: 60% energy; move the handle slowly; 10 mins. Deep Thermal: 70% energy; move the handle quickly; 20 mins. Interval: twice a week Sessions: 8 times Athermal:30% energy; fixed-point operation for 5-10...

Open the catalog to page 14
Smart Tecar Wave with Shockwave 3 in 1 - 15

Picture Treatment area Knee joint Working head Athermal:50% energy; fixed-point operation for 5-10 mins. Medium Thermal: 50% energy; move the handle slowly; 10 mins. Deep Thermal: 60% energy; move the handle quickly; 20 mins Interval: twice a week Sessions: 8 times. Athermal:70% energy; fixed-point operation for 5-10 mins. Medium Thermal: 60% energy; move the handle slowly; 10 mins. Deep Thermal: 70% energy; move the handle quickly; 20 mins. Interval: twice a week Sessions: 10 times Athermal:40% energy; fixed-point operation for 5-10 mins. Medium Thermal: 70% energy; move the handle slowly;...

Open the catalog to page 15
Smart Tecar Wave with Shockwave 3 in 1 - 16

Operating part: Sole Working head: Foot Pad (apply wet paper towels on the foot pedal Operation: Athermal: 10%-20%, 5-10 minutes Medium Thermal: increase 30%-40% for 10 minutes Deep Thermal: increase 40%-60% for 25 minutes Course of treatment: 8 courses, 2 times a week, lasting 4 weeks

Open the catalog to page 16
Smart Tecar Wave with Shockwave 3 in 1 - 17

Electric Muscle Stimulation EMS “Electrical Muscle Stimulation” is an internationally accepted and proven way of treating muscular injuries. It works by sending electronic pulses to the muscle needing treatment; this causes the muscle to exercise passively. When the muscle receives this signal, it contracts as if the brain has sent the signal itself. As the signal strength increases, the muscle flexes as in physical exercise. Then when the pulse ceases, the muscle relaxes and the cycle starts over again, (Stimulation, Contraction and Relaxation.)

Open the catalog to page 17

All Shanghai Goodmed Medical Device catalogs and technical brochures

  1. AIR902

    1 Pages

  2. XY-K-JLC-D

    3 Pages

  3. S610

    2 Pages

  4. S400

    2 Pages

  5. S110

    1 Pages

  6. OM-A-II ECP

    1 Pages

  7. OM-A ECP

    4 Pages

  8. GD-FA

    9 Pages

  9. HB102

    1 Pages

  10. HB101

    1 Pages

  11. HB100

    1 Pages

  12. HB-400W

    1 Pages

  13. HB-200W

    1 Pages

  14. AMT-B

    24 Pages

  15. RTM06

    2 Pages

  16. RTM05

    2 Pages

  17. RTM04

    2 Pages

  18. RTM03

    2 Pages

  19. RTM02

    2 Pages

  20. HB510B rtms

    7 Pages

  21. Smart Tecar

    9 Pages

  22. WB003

    84 Pages

  23. SWT300

    2 Pages

  24. Ruilex

    1 Pages

  25. XY-CJB-II

    6 Pages

  26. HBY-FL15

    9 Pages

  27. HBY-FL20

    9 Pages

  28. 4500U1

    9 Pages

  29. S720

    1 Pages

  30. S530

    1 Pages

  31. S500

    1 Pages

  32. WB-W-E

    6 Pages

  33. AMT-C

    24 Pages

  34. HB-200C

    1 Pages

  35. TMS

    14 Pages

  36. MAGREX-A

    2 Pages

  37. PMST-3

    5 Pages

  38. R02

    13 Pages

  39. RTM01

    2 Pages

  40. TDCS-02

    18 Pages

  41. ZP4

    1 Pages

  42. SJ1

    1 Pages

  43. HB520B rtms

    7 Pages

  44. RT1100

    14 Pages