1. Catalogs
  2. Shanghai Preclinic Medtech
  3. vascular simulation model catalog

vascular simulation model catalog
1 /16Pages

vascular simulation model catalog

vascular simulation model catalog
1 /16Pages

Catalog excerpts

vascular simulation model catalog-1

Neurovascular simulat Neurovascular operation training model- A PLSJXG001 A(Piastic )/PLSJXG004A(Acrylic material, the bottom plate emits light) Neurovascular operation training model-C Product function It is applicable to performance test, functional demonstration and training of intervention devices, such as neurological guidewire, catheter, filter stent, spring coil and stent. Replaceable parts Middle cerebral artery, vertebra! artery Main material Highly transparent soft silicone, hardness- 30A Main components it contains cerebral arteries, such as anterior and posterior middle arteries, basilar arteries, and Circle of Willis with aneurysms and stenosis segments, as well as major vessels and branches involved by neurointerven-tional surgical approach, such as left and right vertebral arteries, left and right common carot-d arteries, thoracic aorta, iliac arteries and femoral arteries. Neurovascular operation training model-B PLSJXG001 B(Plastic )/PLSJXG004B(Acrylic material, the bottom plate emits light) IA<j*>t to FIM-rtfaMd tiling standards! Product function It is applicable to performance test, functional demonstration and training o’ intervention devices, such as neurological guidewire, catheter, filter stent, spring coil and stent Replaceable parts Middle cerebral artery, vertebral artery Main material H-gh!y transparent soft silicone, hardness- 18A Main components It contains cerebral artenes, such as anterior and posterior middle arteries, basilar arteries, and Circle of Willis with aneurysms and stenosis segments, as well as major vessels and branches involved by neuromterventional surgical approach, such as left and right vertebral arteries, left and right common carotid artenes, thoracic aorta, iliac artenes and femoral arteries Two 180-degreebends and two 360-degree bends are added to the siphon section of the internal carotid artery. Preclinic MedtechfShanghai)Co..lt<J Product function Used for performance testing, functional demonstration, and training use of interventional devices such as wires, catheters, filter stents, spring coils, and stents in neurology. Replaceable parts Middle cerebral artery and vertebral artery Main material High transparent soft silicone Main components The cavernous sinus segment |C4 segment) and postenor communicating artery of ICA originate from the C7 segment {communication segment), vertebral artery, anterior cerebral artery At segment, anterior communicating artery, middle cerebral artery M1 segment, posterior cerebral artery PI segment, external iliac artery, femoral artery, abdominal aorta, and renal artery Intracranial femoral vein surgery training model (Adapt to FDA-related testlno standards) Cerebral vein, jugular vein, superior vena cava, right atrium, inferior vena cava and femoral vein approach. Product function It is applicable to per formance test, functional demonstration and training of ■niervention devices, such as neurological guidewire, catheter, filter stent, spring coil and stent. Highly transparent soft silicone* Neurovascular simulat

 Open the catalog to page 1
vascular simulation model catalog-2

Anterior Cerebral Circulation Vessel Model PLXG2001 Main components Carotid artery, anterior cerebral artory, middle cerebral artery Product function Test and demonstrate the passability of the devices in anterior cerebral circulation vessels Main material Blood vessel Highly transparent soft silicone Base plate: Acrylic Plane model of arachnoidblood vessels PLSJXG012 Cerebral venous plane model Posterior Cerebral Circulation Vessel Model PLXG2002 Neurovascular Model with Lesions (Support customization) Main components Vertebral artery, basilar artery, poster.or cerebral artery Product function...

 Open the catalog to page 2
vascular simulation model catalog-3

Coronary Training Model - A (Circular version)PLXZXG003A(Plastic )/PLXZXG018A(Acrylic material, the bottom plate emits light) lAdapt to PDA-'olatod Mandardi) Coronary Training Model - C (Immersion version) PLXZXG013C (Acrylic material, the bottom plate emits light) Main composition Thoracic and abdominal arteries, oppe' limb arteries Replaceable parts Aorta, femoral artery, radial artery, straight segment of coronary artery stenosis lesion, curved segment of coronary artery stenosis lesion Product features Used for vascular Intervention surgical instruments such as catheters, balloon catheters,...

 Open the catalog to page 3
vascular simulation model catalog-4

Cardiac Training Model - Type A PLXZXG004A(Plastic )PLXZXG012A(acrylic) {Adapt to FDA-ralated totting standard*) Right Cardio-Pulmonary Artery Simulation ModelPLXZXG006(Plastic J/PLXZXG015(acrylic) {Ad8p*. to FDA-related testing standards) Main components Superior and inferior vena cava, thoracoabdominal aorta, femora! vein, femoral artery, main body of heart (including left/ right ventricle, septum at oval foramen, pulmonary artery, valves, atna! appendage) Product function It is applicable to performance test, functional demonstration and training of cardiac intervention devices, such as pacemaker,...

 Open the catalog to page 4
vascular simulation model catalog-5

Cardiac Veins Simulation Model (Pacemaker Electrodeimplantation)PLXZXG001 (Plastic )/PLXZXG014 (acrylic) (Adapt to FDA related tasting candardi) Main components Jugular vein, subclavian vein, superior vena cava, main pulmonary artery, coronary vem, right ventricle, right atrium, inferior vena cava, iliac vein, femoral vein Replaceable parts Right ventricle, right atrium and coronary veins are replaceable as a whole Product function ft is applicable to performance test, functional demonstration and training of cardiac intervention devices, such as cardiac pacemaker. electrophys-o'-ogy, atnal septa-puncture...

 Open the catalog to page 5
vascular simulation model catalog-6

Cardiac Electrophysiological Training Model Main components Left atrium, pulmoonry vein, foramen ova In, right atrium, Inferior vena cava, iliac vnio, fnmoral win Replaceable parts Main body of heat Product function Used for cardiac eiectrophysiologicai surgery training, surgical instrument development testing, and demonstration use Ultrasound cardiac training modelPLXZXG016 Main components Ultrasound heart (left ventricular atrium, mitral valve, right ventricular atrium, tricuspid valve, aorta, aortic valve, pulmonary artery, pulmonary valve, pulmonary vein, superior and inferior vena cava),...

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.