Catalog excerpts

Cryotherapy Chamber Brochure
Open the catalog to page 1
About Rlab Cryotherapy Chamber GC - tulip Usage Method GC - tulip Structure Chart Usage Programme
Open the catalog to page 3
Technology Against Aging, Anticipating the Future About Rlab 50+ R&D team 6,500m³ The factory covers an area 10 years Professional solution for anti-aging program 10 years Professional anti-aging equipment manufacturer Shanghai Rejuvelab Biotechnology Co., Ltd, referred to as “Rlab”, is a longevity technology enterprise specializing in the research and development of global cutting-edge anti-aging equipment. The company's brand Rejuvelab, adheres to the values of science and technology to promote healthy aging, with the international leading level of scientific research and production, and...
Open the catalog to page 4
Technology Against Aging, Anticipating the Future GC-elec Ⅰ / GC-elec Ⅱ / GC-elec Ⅲ
Open the catalog to page 5
Technology Against Aging, Anticipating the Future Cryotherapy Chamber Rlab cryotherapy chamber is developed based on the scientific understanding and application of the effect of human physiology, which mainly include: biological research, clinical practice and engineering technology. The development of engineering technology has enable the cryotherapy chamber to provide a more safe precise and comfortable treatment environment. Rlab engineering technology is mainly the innovation of temperature control technology, extreme speed pre-cooling technology, real-time sign monitoring technology,...
Open the catalog to page 6
Technology Against Aging, Anticipating the Future Rlab Technical Parameters Product name: Cryotherapy chamber Model: GC - tulip Power supply: 50Hz±1Hz;single-phase 220V Maximum power: 2300W Refrigeration mode: Liquid nitrogen refrigeration Duct type: Wrap-around cold recovery Cold therapy temperature range: 0℃ ~ -180℃ Maximum working pressure: 2.0Mpa Regular working pressure: 0.5-1.0Mpa Liquid nitrogen consumption rate: 1.5L/min/0.5Mpa Oxygen supply rate: 0.651m³/min Ambient humidity ≤80% Liquid nitrogen valve interface: G 5/8 (national standard) Chamber size: 1600x1000x2400mm (L x W x H)...
Open the catalog to page 7
Technology Against Aging, Anticipating the Future GC - tulip Structure Chart Sleek Light Strip Outer Shell Inner Shell Light Strip Small Entry Door (Pedal) Opening And Closing Hinge Of Front Beze Expandable & Retractable Hinge
Open the catalog to page 8
Technology Against Aging, Anticipating the Future Display Screen (LOGO) Round Foundation Platform Display Screen Lift Platform Intemal Protective Film
Open the catalog to page 9
Technology Against Aging, Anticipating the Future Advantage of GC - tulip Speed pre-cooling intelligent temperature control Rlab Aurora adopts intelligent temperature control system, in the pre-cooling mode, it only takes 30S, the temperature in the chamber can be rapidly reduced to -100C℃, the cold therapy temperature can be precisely controlled between -120C℃ and -190C℃, according to the individual's physical condition, free to regulate the cryogenic environment in the chamber. Signs monitoring Rlab Aurora is equipped with a vital signs monitoring system, which can real-time monitor and...
Open the catalog to page 10
Technology Against Aging, Anticipating the Future Material Aurora cabin is made of PMMA, which has the advantages of non-conductivity, stable performance, high mechanical strength, low-temperature resistance, corrosion resistance, etc., making the cold therapy process safer and more reliable. Electric door Aurora adopts the same type of BMW electric access control system, compared with the traditional manual push and pull, time-consuming and labour-intensive, Aurora can be very easy to operate the closure of the cabin, but also greater enhancement of the confinement of the cabin, reducing...
Open the catalog to page 11
Khfr Technology Against Aging, Anticipating the Future 09 Improve sleep quality 02 03 Promote collagen Relieve anxiety and depression production, Increase skin elasticity Burn fat to lose weight Reduce sports injuries Soothe pain, Eliminate fatigue Improve sports performance 07 Reduce inflammation, Anti-aging
Open the catalog to page 12
Technology Against Aging, Anticipating the Future IQ Applicable items Reduce inflammation Soothe pain Temperature and duration of cryotherapy Freezing programme: -110°C 3-5 times per week, 3 minutes each time, and noticeable improvement felt for two weeks Freezing programme: -120°C 5 times per week 3min each time Two weeks pain reduction and increase in activity index Improve sports | Freezing programme: -130°C 10 times (3min each time) Male performance | athlete's performance > Female athlete's performance Reduce sports | Freezing programme: -140°C 3-5 times per week (3min injuries 1 each...
Open the catalog to page 13
Technology Against Aging, Anticipating the Future 11 07 Temperature adjustment 10 Normal mode 13 Current cabin temperature 16 Current calorie consumption 19 Current cabin temperature 17 Heart rate display 20 Current amount of liquid nitrogen remaining 15 Current remaining time 18 Blood oxygen concentration display 21 Liquid nitrogen consumption display
Open the catalog to page 14
Technology Against Aging, Anticipating the Future Unscrew the liquid nitrogen tank's【liquid phase valve or inlet and outlet Step1 liquid or liquid valve】counterclockwise (according to the nameplate of the actual liquid nitrogen tank) to release liquid nitrogen. Click the pre-cooling button , this operation does not need to set the temperature, the equipment will pre-cool itself to lower the temperature. After the pre-cooling work is finished, click on the door button cabin door opens, and after people enters the cabin and stands steadily, click on the door button Adjust the height of the...
Open the catalog to page 15
Q/ab Technology Against Aging, Anticipating the Future 13 1. Liquid nitrogen is naturally consumed every day, even not use it. The amount of consumption depends on the actual condition of the liquid nitrogen tank, and is usually 2%/day. 2. Before switching on the power, please make sure that the power cord is fully and correctly connected. You 5. When using the device for the first time, please control the experience time, and it is recommended to use the normal mode to experience, and after the body adapts to it, you can choose the extreme mode to experience according to the actual...
Open the catalog to page 16All Shanghai Rejuvelab Biotechnology catalogs and technical brochures
-
Rlab Product Catalog
14 Pages
-
Light Chamber
16 Pages
-
Floatation Chamber
22 Pages
-
Hyperbaric Oxygen Chamber
27 Pages