Cryotherapy Chamber - GC-cryo Ⅰ / GC-tulip II
20Pages

{{requestButtons}}

Catalog excerpts

Cryotherapy Chamber - GC-cryo Ⅰ / GC-tulip II - 1

C爀礀otherapy Chamber Brochur

Open the catalog to page 1
Cryotherapy Chamber - GC-cryo Ⅰ / GC-tulip II - 3

About Rlab C爀礀otherapy Chamber GC - tulip Structure Cha爀琀 Usage Programme GC - tulip Usage Method

Open the catalog to page 3
Cryotherapy Chamber - GC-cryo Ⅰ / GC-tulip II - 4

Technology Against Aging, Anticipating the Future About Rlab 50+ R&D team 6,500m³ The facto爀礀 covers an area 10 years Professional solution for anti-aging program 10 years Professional anti-aging equipment manufacturer SHANGHAI REJUVELAB MEDICAL AND HEALTH TECHNOLOGY Co., LTD, referred to as “Rlab”, is a longevity technology enterprise specializing in the research and development of global cutting-edge anti-aging equipment. The company's brand Rejuvelab, adheres to the values of science and technology to promote healthy aging, with the international leading level of scienti昀椀c research and...

Open the catalog to page 4
Cryotherapy Chamber - GC-cryo Ⅰ / GC-tulip II - 5

Technology Against Aging, Anticipating the Future GC-elec Ⅰ / GC-elec Ⅱ / GC-elec Ⅲ

Open the catalog to page 5
Cryotherapy Chamber - GC-cryo Ⅰ / GC-tulip II - 6

Technology Against Aging, Anticipating the Future C爀礀otherapy Chamber Rlab c爀礀otherapy chamber is developed based on the scienti昀椀c understanding and application of the e昀昀ect of human physiology, which mainly include: biological research, clinical practice and engineering technology. The development of engineering technology has enable the c爀礀otherapy chamber to provide a more safe precise and comfo爀琀able treatment environment. Rlab engineering technology is mainly the innovation of temperature control technology, extreme speed pre-cooling technology, real-time sign monitoring technology,...

Open the catalog to page 6
Cryotherapy Chamber - GC-cryo Ⅰ / GC-tulip II - 7

Technology Against Aging, Anticipating the Future Rlab Technical Parameters Product name: C爀礀otherapy chamber Model: GC - tulip Power supply: 50Hz±1Hz;single-phase 220V Maximum power: 2300W Refrigeration mode: Liquid nitrogen refrigeration Duct type: Wrap-around cold recove爀礀 Cold therapy temperature range: 0℃ ~ -180℃ Maximum working pressure: 2.0Mpa Regular working pressure: 0.5-1.0Mpa Liquid nitrogen consumption rate: 1.5L/min/0.5Mpa Oxygen supply rate: 0.651m³/min Ambient humidity ≤80% Liquid nitrogen valve inte爀昀ace: G 5/8 (national standard) Chamber size: 1600x1000x2400mm (L x W x H)...

Open the catalog to page 7
Cryotherapy Chamber - GC-cryo Ⅰ / GC-tulip II - 8

Technology Against Aging, Anticipating the Future GC - tulip Structure Cha爀琀 Sleek Light Strip Outer Shell Inner Shell Light Strip Small Ent爀礀 Door (Pedal) Opening And Closing Hinge Of Front Beze Expandable & Retractable

Open the catalog to page 8
Cryotherapy Chamber - GC-cryo Ⅰ / GC-tulip II - 9

Technology Against Aging, Anticipating the Future Display Screen (LOGO) Round Foundation Platform Display Screen Lift Platform Intemal Protective Film

Open the catalog to page 9
Cryotherapy Chamber - GC-cryo Ⅰ / GC-tulip II - 10

Technology Against Aging, Anticipating the Future Advantage of GC - tulip Speed pre-cooling intelligent temperature control Rlab Aurora adopts intelligent temperature control system, in the pre-cooling mode, it only takes 30S, the temperature in the chamber can be rapidly reduced to -100C℃, the cold therapy temperature can be precisely controlled between -120C℃ and -190C℃, according to the individual's physical condition, free to regulate the c爀礀ogenic environment in the chamber. Signs monitoring Rlab Aurora is equipped with a vital signs monitoring system, which can real-time monitor and...

Open the catalog to page 10
Cryotherapy Chamber - GC-cryo Ⅰ / GC-tulip II - 11

Technology Against Aging, Anticipating the Future Material Aurora cabin is made of PMMA, which has the advantages of non-conductivity, stable pe爀昀ormance, high mechanical strength, low-temperature resistance, corrosion resistance, etc., making the cold therapy process safer and more reliable. Electric door Aurora adopts the same type of BMW electric access control system, compared with the traditional manual push and pull, time-consuming and labour-intensive, Aurora can be ve爀礀 easy to operate the closure of the cabin, but also greater enhancement of the con昀椀nement of the cabin, reducing...

Open the catalog to page 11
Cryotherapy Chamber - GC-cryo Ⅰ / GC-tulip II - 12

Technology Against Aging, Anticipating the Future Improve sleep quality Promote collagen Relieve anxiety and depression production, Increase skin elasticity Burn fat to lose weight Reduce spo爀琀s injuries Soothe pain, Eliminate fatigue Reduce in昀氀ammation, Improve spo爀琀s pe爀昀ormanc

Open the catalog to page 12
Cryotherapy Chamber - GC-cryo Ⅰ / GC-tulip II - 13

Technology Against Aging, Anticipating the Future Usage Programme Applicable items Temperature and duration of c爀礀otherapy Freezing programme: -110℃ 3-5 times per week, 3 minutes each time, and noticeable improvement felt for two weeks Soothe pain Improve spo爀琀s pe爀昀ormance Reduce spo爀琀s injuries Burning fat lose weight Applicable items Freezing programme: -120°C 5 times per week 3min each time Two weeks pain reduction and increase in activity index Freezing programme: -130°C 10 times (3min each time) Male athlete's pe爀昀ormance > Female athlete's pe爀昀ormance Freezing programme: -140°C 3-5...

Open the catalog to page 13
Cryotherapy Chamber - GC-cryo Ⅰ / GC-tulip II - 14

Technology Against Aging, Anticipating the Future GC - tulip Usage Method 17 13 Current cabin temperature 15 Current remaining time 16 Current calorie consumption 17 Hea爀琀 rate display 18 Blood oxygen concentration display 19 Current cabin temperature 21 Liquid nitrogen consumption 20 Current amount of liquid nitrogen remaining

Open the catalog to page 14
Cryotherapy Chamber - GC-cryo Ⅰ / GC-tulip II - 15

Technology Against Aging, Anticipating the Future Unscrew the liquid nitrogen tank's【liquid phase valve or inlet and outlet Step1 liquid or liquid valve】counterclockwise (according to the nameplate of the actual liquid nitrogen tank) to release liquid nitrogen. Click the pre-cooling button , this operation does not need to set the temperature, the equipment will pre-cool itself to lower the temperature. After the pre-cooling work is 昀椀nished, click on the door button cabin door opens, and after people enters the cabin and stands steadily, click on the door button Adjust the height of the...

Open the catalog to page 15
Cryotherapy Chamber - GC-cryo Ⅰ / GC-tulip II - 16

Technology Against Aging, Anticipating the Future Notes on the Use of GC - tulip 1. Liquid nitrogen is naturally consumed eve爀礀 day, even not use it. The amount of consumption depends on the actual condition of the liquid nitrogen tank, and is usually 2%/day. 2. Before switching on the power, please make sure that the power cord is fully and correctly connected. You 3. When entering the chamber, you need to prepare the end tissues of your body against freezing, such as hands, feet, ears and other pa爀琀s. 4. During use, please make sure that your head is completely exposed to the cabin before...