Hyperbaric Oxygen Chamber
26Pages

{{requestButtons}}

Catalog excerpts

Hyperbaric Oxygen Chamber - 1

Hyperbaric oxygen chamber brochure

Open the catalog to page 1
Hyperbaric Oxygen Chamber - 3

About Rlab Introduction to RLAB Hyperbaric Oxygen Chamber Main Function Rlab Time Pearl Structure Diagram Operating Instructions Rlab Time Shuttle Structure

Open the catalog to page 3
Hyperbaric Oxygen Chamber - 4

Technology Against Aging, Anticipating the Future About Rlab 50+ R&D team 6,500m³ The factory covers an area 10 years Professional solution for anti-aging program 10 years Professional anti-aging equipment manufacturer SHANGHAI REJUVELAB MEDICAL AND HEALTH TECHNOLOGY Co., LTD, referred to as “Rlab”, is a longevity technology enterprise specializing in the research and development of global cutting-edge anti-aging equipment. The company's brand Rejuvelab, adheres to the values of science and technology to promote healthy aging, with the international leading level of scientific research and...

Open the catalog to page 4
Hyperbaric Oxygen Chamber - 5

Technology Against Aging, Anticipating the Future

Open the catalog to page 5
Hyperbaric Oxygen Chamber - 6

Technology Against Aging, Anticipating the Future Introduction to Rlab Hyperbaric Oxygen Chamber Rlab hyperbaric oxygen chamber is a civil hyperbaric chamber developed based on the standard of medical hyperbaric oxygen chamber, the pressure can be adjusted (1.3~2.0ATA), rlab hyperbaric oxygen chamber has independent research and development technology, including manual automatic control valve, with oxygen production and pressure integrated technology and intelligent control system. The 2019 Nobel Prize in physical or medical revealed that cell are sensitive to the oxygen content of their...

Open the catalog to page 6
Hyperbaric Oxygen Chamber - 7

Technology Against Aging, Anticipating the Future There are two forms of oxygen: conjugated oxygen and dissolved oxygen. Oxygen is found in two forms in the blood: hemoglobin-bound oxygen and dissolved oxygen in plasma. Bound oxygen: hemoglobin in red blood cells is combined with oxygen, and its carrying capacity can be expressed by blood oxygen saturation, arterial oxygen saturation is 95~98%, venous blood is 75% Dissolved oxygen: The amount of oxygen dissolved in the plasma is much smaller than the amount of bound oxygen, and the amount of dissolved oxygen is directly proportional to the...

Open the catalog to page 7
Hyperbaric Oxygen Chamber - 8

Technology Against Aging, Anticipating the Future Rlab HBO Advantages Rlab hyperbaric oxygen chamber can be controlled and use both inside and outside Intelligent control system Installation-free, easy to install Multiple security protections It integrates air compressor, oxygen concentrator and cooler

Open the catalog to page 8
Hyperbaric Oxygen Chamber - 9

Technology Against Aging, Anticipating the Future Multiple pressure are optical and can be customized Manual automatic control valve Air conditioner for pressurised oxygen tank Multi-cavity air intake silencer Air pressurisation and molecular sieve oxygen multi-function machine High-pressure molecular sieve oxygen generator and molecular sieve oxygen generator module with pressure-raising function Air Pressurised Oxygen Chamber Mask Type Oxygen Absorption and Discharge Device

Open the catalog to page 9
Hyperbaric Oxygen Chamber - 10

Technology Against Aging, Anticipating the Future Improve age-related immune dysregulation Improve antioxidant Inhibit cellular cells to promote tissue regeneration 07 Cognitive improvement, skin regeneration, metabolic regulation, musculoskeletal repair and cardiopulmonary function improvement, etc.

Open the catalog to page 10
Hyperbaric Oxygen Chamber - 11

Technology Against Aging, Anticipating the Future Rlab Hyperbaric Oxygen Chamber Product Parameters Product name:Time Pearl Model:HBO150 HBO200 HBO250 Operation mode: Touch dual-screen control, the chamber for the mobile tablet computer control Power supply: 50Hz±1Hz; single-phase 220V (can be customised) Power: 1650W 1800W 2000W Working pressure: 1.1-2.5ATA Chamber size: 1600*950*1500mm (L*W*Hmm) Oxygen concentration: 95%±3 Pressurised medium: Air Chamber material: Q235 manganese steel + Polycarbonate sheet Chamber weight: 310KG

Open the catalog to page 11
Hyperbaric Oxygen Chamber - 12

Technology Against Aging, Anticipating the Future Rlab Time Pearl Structure Diagram Front View of Mainframe Control panel Power switch Cabinet handle Talking machine Universal wheel

Open the catalog to page 12
Hyperbaric Oxygen Chamber - 13

Technology Against Aging, Anticipating the Future Back View of Main Unit Power socket Communication socket Air terminal Oxygen terminal Cabin Front-Exterior Observation window Door hinges Pressure gauge Outer handle Door sensing Universal wheel Pressurisation valve pressure reduction valve

Open the catalog to page 13
Hyperbaric Oxygen Chamber - 14

Technology Against Aging, Anticipating the Future Cabin Fronts - Interior Automatic lock Inner handle Armrests Cabin Back Power socket Communication socket Manual emergency relief valve Oxygen terminal Air terminal

Open the catalog to page 14
Hyperbaric Oxygen Chamber - 15

Technology Against Aging, Anticipating the Future Operating instructions Power On 1. Turn on the power supply of the cabin , the power indicator lights up, plus or minus the pressure of the automatic valve pointer to zero 2. Open the host power check whether the host is normal start, check the display data 3. Press the cabin call button check the call (Note: short press call; press 3-5 seconds emergency pressure relief)

Open the catalog to page 15
Hyperbaric Oxygen Chamber - 16

Technology Against Aging, Anticipating the Future Switch on The Machine 1. Click button ① ② ③ to adjust the pressure, time and speed of pressure relief respectively, and click button ⑥ to choose the light mode according to your personal situation; then click button ⑦ to start the operation. 2. After pressing the ‘Start’ button, click ‘Confirm’ in the pop-up window to start the device. 3. Precautions before and after startup: Š After startup, pay attention to whether the humidifier is producing oxygen; Š If you start the device before entering the cabin, the interval between clicking ‘Start’...

Open the catalog to page 16
Hyperbaric Oxygen Chamber - 17

Technology Against Aging, Anticipating the Future Operation Process 1. When the pressure in the chamber is greater than 50mbar, the chamber auto-lock will lock the hatch handle to prevent the hatch from being opened by mistake. 2. Oxygen flow size can be adjusted through the chamber humidification pot regulating valve, according to the direction of the arrow to rotate the adjustment, generally set the flow rate of 5L / min. 3. It is normal that the oxygen flow rate of pressurisation stage and constant pressure stage is lower than that of decompression stage, especially when the pressure...

Open the catalog to page 17