Shanghai TOW Intelligent Technology Co.,Ltd. Handheld Animal Monitor VSM-50 Features 1. 5 - inch LED screen (touch screen), NIBP (blood pressure), SPO2 (blood oxygen), TEMP (body temperature) /EtCO2 ( end-tidal carbon dioxide ) (one of them can be selected) 2. It can be flexibly configured with NIBP/SPO2/WIFI/base , desktop, hand-held, bracket, and flexible assembly methods, which can meet various clinical environments 3. Capacitive touch screen, shortcut keys, and random operation 4. High - resolution LED screen, stable user interface style, highlighting professional equipment 5. The blood oxygen weak perfusion performance can reach 0.05%, which can meet the blood oxygen saturation measurement in various environments 6. The battery can work for up to 15 hours Technical Parameter Model Display parameters 5 inch LED touch screen , high resolution LED Package dimension
Open the catalog to page 1Shanghai TOW Intelligent Technology Co.,Ltd. SpO2 SpO2 measurement range SpO2 measurement accuracy SpO2 alarm range 0% to 100% The error is ±2% within the range of 70% to 100%,2 other ranges are undefined Consistent with the display range, the step length of the alarm limit setting is 1% Pulse rate measurement range Average SpO2 pulse rate Wavelength range Maximum luminous power Operating mode Manual, automatic, continuous The maximum average error is ±5 mmHg (±0.67 Measurement accuracy kPa), and the maximum standard deviation is 8 mmHg (1.067 kPa), whichever is greater in absolute value....
Open the catalog to page 2Shanghai TOW Intelligent Technology Co.,Ltd. setting step length is 1mmHg or 0.1kPa TEMP TEMP measurement range TEMP measurement accuracy ±0.1℃ Consistent with the display range, the step length Alarm setting range of the alarm limit setting is 0.1°C Alarm delay time Minimum time to display correct TEMP reading About 1 second Update time Measurement mode, standby mode Measuring range 0mmHg~150mmHg(0kPa~19.95kPa) Within the range of 0 mmHg~40 mmHg (0 kPa~ 5.33 kPa), the error is ±2 mmHg (±0.3 kPa); Within the range of 41 mmHg~100mmHg (5.47 kPa~ 13.3 kPa), the error is ±5 mmHg (±0.7 kPa);...
Open the catalog to page 3Shanghai TOW Intelligent Technology Co.,Ltd. WIFI, two microcode scanning, mainstream CO2 (UGS20) , body cavity probe Blood pressure extension tube reusable 2 meters Veterinary Blood Pressure Cuff No. 1 Veterinary Blood Pressure Cuff No. 2 Veterinary Blood Pressure Cuff No. 3 Veterinary Blood Pressure Cuff No. 4 Veterinary Blood Pressure Cuff No. 5 Charging data cable type-c 5A 8-core dual-slot 2.25K body cavity temperature probe Handheld product base Shanghai TOW Intelligent Technology Co.,Ltd. Web: www.tow-int.com Email: zhaoj@tow-int.net No.351, Sizhuan Road, Songjiang Disctrict,...
Open the catalog to page 4All Shanghai TOW Intelligent Technology catalogs and technical brochures
-
Animal Monitor VSM-700
3 Pages