1. Catalogs
  2. Shanghai TOW Intelligent Technology
  3. Laser Speckle Blood Flow Imager

Laser Speckle Blood Flow Imager

Laser Speckle Blood Flow Imager

Laser Speckle Blood Flow Imager

Product catalog summary
Introduction
The Laser Speckle Blood Flow Imager (LSI-BFI) is an advanced imaging technology designed for animal experiments and clinical research. It provides real-time, non-invasive visualization of microcirculatory blood flow, aiding in research areas such as cardiovascular disease, drug efficacy, neuroscience, and wound repair.

System Working Principle
Laser speckle imaging works by analyzing the interference pattern created when a laser beam reflects off a target. The movement of red blood cells causes fluctuations in this pattern, which are quantified by speckle contrast to assess blood perfusion volume. This technology is valuable for studying microcirculation dynamics in various pathological conditions.

Key Features and Benefits
  • Optimized Dynamic Speckle Algorithm: Eliminates motion artifacts for stable imaging.
  • Ultra-sensitive CMOS Sensor: Captures high SNR images in low-light conditions.
  • Temperature-Controlled Laser Safety System: Complies with international safety standards, ensuring operator and animal safety.
  • High-Resolution Real-Time Imaging: Captures up to 122 frames per second with high spatial resolution.
  • Non-Invasive Monitoring: Avoids stress responses in animals, ensuring authentic data.
  • Multi-scenario Adaptability: Suitable for various animal sizes and chronic disease research.
  • Smart Analysis Software: Provides quantitative parameters and supports 3D blood flow reconstruction.
  • Portability and Expandability: Modular design for fixed or mobile use, with integration options for additional modules.

Technical Highlights
Applications include research on ischemia-reperfusion injury, tumor angiogenesis, and inflammatory responses, as well as drug development and clinical veterinary medicine.

Why Choose Us?
  • Scientific-research-grade accuracy with high consistency in quantitative flow method verification.
  • Free training on equipment operation and standardized procedures.
  • Global warranty with 3-year coverage and lifetime technical support.
  • Customized development options for analysis modules and hardware extensions.

Technical Parameters
Key parameters include a resolution of 2688x1520, maximum frame rate of 122fps, and a working distance adjustable from 10-40 cm. The system supports various output formats and imaging compositions.

Service Support
Includes patents, citations, and qualification certifications, with a focus on professional manufacturing for scientific research instruments.
See more

Catalog excerpts

Laser Speckle Blood Flow Imager-1

National Patent Certificate Quality Management System Certification High - tech Enterprise Laser Speckle Blood Flow Imager (LSI-BFI) Non-invasive Blood Flow Monitoring, Facilitating Scientific Research and Pre-clinical Diagnosis The Laser Speckle Blood Flow Imager (LSI-BFI) is an advanced imaging technology based on the dynamic analysis of laser speckles. It is specifically designed for animal experiments and clinical research. By capturing the dynamic changes of microcirculatory blood flow in living tissues in real-time and non-invasively, it provides a precise visualization tool for fields such as cardiovascular disease research, drug efficacy evaluation, neuroscience, and wound repair. Shanghai TOW Intelligent Technology Co.,Ltd

 Open the catalog to page 1
Laser Speckle Blood Flow Imager-2

System Working Principle The principle of laser speckle imaging is as follows: When the target is irradiated by a laser beam, the reflected laser forms a random interference image (including bright and dark areas), which is called a laser speckle pattern. If the measured target is stationary, the laser speckle pattern remains unchanged. If the measured object moves, for example, the movement of red blood cells in tissues, the laser speckle pattern will fluctuate accordingly. The change speed of the laser speckle pattern depends on the movement speed of the target in the monitored area; the faster...

 Open the catalog to page 2
Laser Speckle Blood Flow Imager-3

Benefits High-speed imaging ability of up to 122 frames per second, dynamically capturing the High-ResolutiOntransient changes of blood flow. Real-Time Imaging• Spatial resolution reaches 2688x1520, clearly presenting the details of the microvas- cular network and blood flow distribution. • No need for injecting contrast agents or invasive operations, avoiding the stress response of animals and ensuring the authenticity of experimental data. • Supports long-term repeated observations, suitable for the research of chronic disease models. Multi-scenario • Compatible with various experimental animal...

 Open the catalog to page 3
Laser Speckle Blood Flow Imager-4

Application Areas Research on ischemia-reperfusion injury, tumor angiogenesis, and Basic Research Clinical and Veterinary Medicine inflammatory response mechanisms; Neurovascular coupling (such as blood flow monitoring in stroke models). Drug Development Clinical and Veterinary Medicine Dynamic evaluation of the efficacy of vasoactive drugs, anticoagulants, and anti-tumor drugs; New drug toxicology research (monitoring of organ blood flow side effects). Diagnosis of peripheral vascular diseases in pets and economic animals (such as diabetic foot, burn repair assessment); Real time blood flow...

 Open the catalog to page 4
Laser Speckle Blood Flow Imager-5

Technical Parameters Image Pixel Maximum Frame Rate Gray-scale Bit Depth Color Bit Depth Imaging Laser Output Files Image Composition Imaging Field of View avi video, tiff image (color 24bit RGB, gray-scale 16bit, pseudo-color 16bit), csv data table, html/pdf report Physical map, laser (speckle) map, (speckle) comparison map, pseudo-color map, overlay map, etc. 14mm×22mm~57mm×100mm Working Distance Continuously adjustable from 10-40 cm Focusing Method Fast autofocus, electric fine-focus Equipped with a calibration box Service Support Free Training Global Warranty Customized Development Provide...

 Open the catalog to page 5
Laser Speckle Blood Flow Imager-6

P atents a nd C it a t ions Patents and Citations Acquired Patents Qualification Certifications *Due to limited space, for more information, please call for consultation. Pr o fe ssi o n a l m anufacturer of scientific research instruments for experimental animals www. t ow-i n t.n e t

 Open the catalog to page 6

All Shanghai TOW Intelligent Technology catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.