Installation Instruction 1. Ceiling mount height details To: Shanghai Weyuan Medical Device Co., Ltd Structural Ceiling Fixing point to underside of suspended ceiling MAX LENGTH 1m Provide measurements below on the ceiling type at site. Structural Ceiling Suspended Ceiling In certain installations where the distance between the suspended ceiling and fixing point is greater than 1000mm, a separate mounting structure may be required to be installed by the client. See WEYUAN "Cotton Reel Extension" option. Available as a separate PDF download and optional purchase. Please contact WYUAN to discuss any queries you might have to. achieve the best possible solution. For Installations direct to a structural ceiling, please advise dimension A For Installations with a suspended ceiling, please advise dimensions at B and C 1
Open the catalog to page 1
2. Ceiling height and installation Method for WYLED700/500, WYLED5/3, WYLED650/650 Series (double ceiling, single ceiling are same) Installed in the structural ceiling (roof) Distance between structural ceiling and floor An extension frame is needed Installed directly Low ceiling height design needed Floor standing type Installed in the suspended ceiling( an extension frame is needed) Distance between suspended and floor An extension frame is needed Installed directly Low ceiling height design needed Floor standing type Diagram of flange plate and ref. Picture of Extension fra
Open the catalog to page 2
3. Ceiling height and installation Method for WYLEDK and WYK series ® Installed in the structural ceiling (roof)
Open the catalog to page 3
4. Ceiling height and installation Method for WYLEDK9/4, WYLEDK9/5, WYLEDK12/4, WYLEDK12/5 and WYK9/4, WYK9/5, WYK12/4, WYK12/5series DOUBLE DOME Distance between structural ceiling and floor (2 Installed in the suspended ceiling( an extension frame is needed)
Open the catalog to page 4
For WYLED700/500 series, the best installation height is 2.7-3.1 meters, both for single ceiling and double ceiling. 2 For WYLEDK, WYK series, the best installation height is 2.6-3.0 meters, for single ceiling. 1 The best installation height refers to the distance between the installation site to the ground. 4 The installation site needs to be solid concrete or bear a long-term load of more than 500kg for double dome and 300kg for single dome. 5 If installed on a suspended ceiling, a customized extension frame needs to be fixed on the solid concrete roof. The length of the extension frame...