1. Catalogs
  2. SHARPLINE Surgical Innovations And Technologies
  3. Bio-Barrier / Valve Sterilization container Model - Meddle Size

Bio-Barrier / Valve Sterilization container Model - Meddle Size

Bio-Barrier / Valve Sterilization container Model - Meddle  Size

Bio-Barrier / Valve Sterilization container Model - Meddle Size

Product catalog summary
Sterile Container Systems Overview
Sharpline Bio-Barrier model sterilization container systems are designed with mechanical valves in both the bottom and lid, eliminating the need for disposable filters and allowing for a minimum of 5000 sterilization cycles. The system operates using atmospheric pressure changes within an autoclave during sterilization, ensuring steam penetration and exhaust without manual intervention. Special silicone gaskets ensure 100% valve closure, maintaining sterility post-process. The mechanical valve system is user-demountable for inspection.

Specifications and Features
The containers are available in five different sizes, each equipped with safety lids that protect the valve mechanism from liquids and dust without interfering with sterilization. They include a modular auto-lock mechanism (thermos-lock) for sterility assurance and an indicator window for visual control of the sterilization indicator card.

Model Variants and Accessories
The document lists various model codes and sizes, including specific baskets and accessories like dividers, wire bases, drape retainers, and aluminum baskets with lids. Identification labels and security seals are also available, with options for customization.

Operational Procedure
The Barrier Model operates with valves in three positions during sterilization: relax (pre-sterilization), open (during sterilization due to vacuum and pressure changes), and relax (post-sterilization). This ensures effective sterilization and maintenance of sterility.

Additional Notes
All container measurements include the outer size of the lids, and specific recommendations are provided for label use to prevent color fading due to sterilization processes.
See more

Catalog excerpts

Bio-Barrier / Valve Sterilization container Model - Meddle  Size-1

STERILE CONTAINER SYSTEMS BIO-BARRIER VALVE MODEL EXTRA LARGE SIZE EXTRA LONG SIZE Sharpline Bio-Barrier model sterilization container systems are designed with mechanical valves both in bottom and lid which run in a way that they do not need any disposable filter use and can be used minimum 5000 cycles. The mechanical valve systems set on the lid or box run with atmospheric pressure occurring in the autoclave during sterilization. When the sterilization process starts, because of the occurring (positive) pressure, the valves open and let the steam penetration into the sterilization container. When the vacuum process starts at the end of the sterilization, because of the occurring (negative) pressure, the steam outlet valve opens and the steam exhausts from the box. When the sterilization process is completed, as there is no pressure (positive or negative) in autoclave, both valves are in closed position. By this way, it gains qualification to keep the products in it as sterilized. The valves are ensured to be closed %100 due to the special silicone gaskets on mechanical valve systems. Moreover, the mechanical valve system these sterilization containers is demountable by the user in order to control it when desired. Sharpline Bio-Barrier model sterilization container systems are manufactured as five different lengths, width and height and can be supplied with safety lids for effective external protection. These safety lids do not interfere with sterilization and they provide protection to the valve mechanism against liquids and dust as a second lid. All models and sizes have specific baskets and accessories which can be viewed in following parts. Modular auto lock mechanism (thermos-lock) promising sterility assurance and indicator window providing visibility of the indicator card result by visual control without opening the lid are also available for this sterilization container model.

 Open the catalog to page 1
Bio-Barrier / Valve Sterilization container Model - Meddle  Size-2

3/4 Bio-Barrier - Valve Model 80.34 80.34 cover the outer size of the lids.

 Open the catalog to page 2
Bio-Barrier / Valve Sterilization container Model - Meddle  Size-3

Code Color Weight code color Grey colored recommended for use in Starred. Color fading by effect of Hydrogen Peroxide Gas Plasma on other colors.

 Open the catalog to page 3
Bio-Barrier / Valve Sterilization container Model - Meddle  Size-4

WIRE BASE DRAPE RETAINER DRAPE RETAINER ALUMINIUM BASKET (with lid) ALUMINIUM BASKET (with lid) SECURITY SEAL 52.01 100 pcs. with indicator. made of plastic ALUMINIUM BASKET (with lid) SILICONE HANDLE LABELS (paper) 50.02 100 pcs. With indicator. For small size and special containers Auto Lock Mechanism S1-900 (2 Pcs) LABELS (paper) 50.01 100 pcs. With indicator. For full and Half size containers SECURITY SEAL 52.02 100 pcs. with indicator. made of plastic

 Open the catalog to page 4
Bio-Barrier / Valve Sterilization container Model - Meddle  Size-5

STERILE CONTAINER SYSTEMS Bio-Barrier Model The Barrier Model is a mechanical filtering systems. The valves of Barrier Model Systems have three different positions during sterilization cycles such as relax position, before sterilization and after sterilization position. It can be used at least 5000 sterilization cycle. 1 Before sterilization cycle the valves of the Barrier Model Container are closed and in relax position. 2 At the beginning of the sterilization cycle, by the effect of vacuum the valves are opened completely and dry air goes out of the container. 3 During the sterilization cycle...

 Open the catalog to page 5
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.