AMD-RS-AF0001-L Spo2 Sensor Adult Forehead
1 / 1Pages

Catalog excerpts

AMD-RS-AF0001-L Spo2 Sensor Adult Forehead - 1

Technical Specifications: Cable Color Cable Diameter Cable Material Packaging Type Packaging Unit Patient Size Connector Distal Total Cable Length Period of use 3 years if you don’ open package t 1.3 Pulse rate test range: 30~245 bpm; Accuracy: 150 bpm -245 bpm /±3 bpm, bpm -149 bpm/±2 bpm, bpm -59 bpm/±1 bpm。 60 30 1.4 Under the environment temperature of 35℃,The maximum allowable temperature of the contact part between a blood oxygen probe and human body shall be no larger than 41℃. 1.5 Test method for measuring range and measuring precision of SpO2 :Use a supporting device matching the tested spo2 sensor; connect the tested spo2 sensor and the supporting device, and connect them with a blood oxygen simulation tester. Set the simulated pulse of simulated tester to 75bpm,the oxygen saturation figure are set to 70%, 80%, 90%, 96% and 100%, observe and record the matching supporting device oxygen saturation indication,the result of test conform 5.2. Connect correctly patient monitor and oximeter to collect and tranfer patient’ spo2 and signal of pulse’ rate. s s Not suitable for state of weak perfusion and movement to monitor. the probe is not suitable for long-term monitoring, should be checked every 4 hours or change other finger to measure . Put it in a sealed plastic bag after cleaning and drying.The surrounding environment should meet the following conditions: Temperature: - 5 ℃ ~ + 40 ℃, relative humidity is not more than 80%, atmospheric pressure: 45kpa to 110kpa. temperature: 0 ℃ to 40 ℃;Relative humidity: no more than 80%;Pneumatic: 86kpa to 106kpa. Shenzhen Amydi-med Electrics Tech Co.,Itd. Add: 6F, No.15 Building, Xianan No.3 Industrial Zone, Shangcun, Gongming Street, Guangming District, Shenzhen, 518106, China

Open the catalog to page 1

All Shenzhen Amydi-med Electronics Tech catalogs and technical brochures

  1. AMD-US060V

    1 Pages