Amydi-med BIS EEG Electrode AMD-DE-AF0001-1
1Pages

{{requestButtons}}

Catalog excerpts

Amydi-med BIS EEG Electrode AMD-DE-AF0001-1 - 1

a. Wipe skin with 75% medical alcohol and dry b. ①Put it at the center of the forehead (approximately 5cm above the bridge of the nose) e. Press the edge of the electrode ① ②③④ f. Connect the adapter cable (If there is no signal when connecting for the first time, please try to connect again.) 1. Do not open the package unless use it immediately. 2. Do not use it if the package is damaged. 3. Single-use non-sterile product, repeated use is strictly prohibited, cleaning and disinfection are required for the first use. 4. If a rash or other abnormal symptoms occur, stop use and remove it. 5. Only for short time use (up to 24 hours). 6. Do not cut or fold it. 7. Do not use during MRI scan, because conductor current will cause burns. 8. Do not change or modify this product, otherwise will affect its performance and accuracy . 9. Do not use radiation and steam sterilization for disinfection. 10. Do not immerse the product in liquid for clean and disinfection. 11. Disposable non-invasive EEG sensor must be used by professional anesthesia. 12. After use this product, you need to dispose of the equipment in accordance with local regulations. 13. If the electrode can not work normally, you should immediately contact the after-sales service company and do not repair it by yourself. One end is connected with the EEG monitoring equipment, and the other end is connected with the human skin of head for to collecting and transmitting EEG biological signals. Do not use this product on the damaged part of the patient’ s skin.Do not use for people with skin allergies. Ambient temperature: 10℃~40℃, Relative humidity : 30%~70%, Atmospheric pressure: 70kpa~106kpa. Temperature: -20℃~70℃ Humidity: ≤85% Atmospheric pressure: 700hPA~1060hPA Valid period: 1 year Please refer to the label for product model, LOT, production date, expiration date, etc. Manufacturer:Shenzhen Amydi-med Electronics Tech Co.,Ltd Address: 3F,3 Building Hua hong Xin Tong industrial Park,Interchange of Genyu Road and Nanming Road,Tianliao community,Gongming street, Guangming New District 518132,Shenzhen, Guangdong, PEOPLE’ PEPUBLIC OF CHINA S Website: www.amydi-med.com Tel: 86-755-23422883 Single patient use Non Sterile LATEX latex free User manual

Open the catalog to page 1

All Shenzhen Amydi-med Electronics Tech catalogs and technical brochures

  1. AMD-US060V

    1 Pages