Ultrasonic Vascular Doppler Detector (BV-520)
Open the catalog to page 1Product comparison chart > BV-520 Appearance difference S.Omhz probe
Open the catalog to page 2Clear sound quality Intelligent noise reduction Noninvasive velocity measurement Accurate data Widely usage Powerful function Small size and easy to use Portable, small size, built-in high-capacity rechargeable battery, easy to use and flexible to cany. Convenient for doctors or professionals to test patients anytime and anywhere.
Open the catalog to page 3The blood flow velocity is judged by the blood flow sound intensity Confirm key / menu key On/off key Work indicator Power reminder indicator Charging socket Probe socket
Open the catalog to page 5Patented technologyComplete certificates and use reassurance Class II medical device registration certificate has been obtained. Registration Certificate No.: Guangdong Machinery registration standard 20172231863 Registration No.:ZL 2019 2 0477142.5 Patent No.: 2017SR727720 certification, domestic high standards, more assured. _atflf MMnnni._ itAii aimai.a
Open the catalog to page 6Wide usage and powerful function Burns Surgery Urology
Open the catalog to page 7• The blood flow of human artery / vein was detected by 8.0mhz blood flow probe; • It is used to cheek the effect of finger / toe and limb vascular anastomosis; • Built in high-quality speaker, output blood flow sound is clear and loud; • Built in high-eapaeity rechargeable battery to meet long-time work; • Handheld equipment, small size, easy to use; • The bar led cursor indicates the blood flow intensity; Bv-520 is a specially designed pocket Doppler blood flow detector with LCD cursor display. I he blood How \elocity of peripheral artery can be detected by the microprocessor in the instrument...
Open the catalog to page 8BEsmnn z&oixi® miss anting
Open the catalog to page 9The first step is to take out the ultrasonic probe and add an appropriate amount of couplant The second step is to find the brachial artery, which should be inclined 45 cto the artery (Note: do not side the artery) Move slowly left and right to find the maximum sound position Note: the probe is tilted 45 ° to make it easier to measure blood flow The blood flow velocity is judged by the blood flow sound intensity
Open the catalog to page 10Figure for judging vascular obstruction Complete vascular occlusion
Open the catalog to page 11Real picture display SHENZHEN BESTMAN INSTRUMENT CO.,LTDwww.szbestman.cn Add: 8/F.YiFang Bldg,No.315 Shuangming Ave.Dongzhou Community, Guangming St.,Guangming Dist., Shenzhen, Guangdong,518107, China