BSM BVseries Ultrasound Doppler Blood Flow Detectors are mainly used for the detection of human arterial blood flow conditions. Its applications include diabetes screening, peripheral vascular disease detection, atherosclerosis detection, cardiovascular disease detection, uterine blood flow monitoring during pregnancy, male genital problems detection, postoperative recovery status monitoring, and animal artery and capillary status monitoring . Applicable to departments such as urology, orthopedics, surgery, burns and plastic surgery, cardiothoracic surgery, endocrinology and other...

Open the catalog to page 2
Vascular Doppler Catalogue - 3

BVseries ultrasound Dopplers’Parameters Definition u Blood flow waveform: it can check the blood flow status; u Blood flow intensity: it is to judge whether the blood flow is unobstructed or not by observing the intensity of the indicator light and the sound;

Open the catalog to page 3
Vascular Doppler Catalogue - 4

BVseries ultrasound Dopplers’Parameters Definition u Blood flow speed: it is an important physiological parameter of the human body. It has important reference value for disease research and clinical diagnosis. The reference value is as follows: • Arterial blood flow velocity of upper extremity: 40-160cm/s; • The average velocity of peak blood flow of brachial artery: 75.00+-22.00cm/s; • Peak blood flow velocity of radial artery: 42.5+-12.50cm/s; • Peak blood flow velocity of ankle artery: 42.0+-14cm/s; • Peak dorsal artery blood flow velocity: 40.0+-

Open the catalog to page 4
Vascular Doppler Catalogue - 5

BVseries ultrasound Dopplers’Parameters Definition u Pulse rate: The pulse rate of a normal person is equal to the heart rate, and the pulse rate of an adult is 60-100 beats per minute. There is a slight difference between men and women. The pulse rate of women is generally faster than that of men; the pulse rate of the elderly is slower,55-60 beats per minute for elderly; the pulse rate of infants and young children is relatively fast,120-140 beats per minute. u Reference range of blood viscosity: • Male: 3.43-5.07mPa.s • Female: 3.01-4.29mP

Open the catalog to page 5
Vascular Doppler Catalogue - 6

Standard Blood Flow Cycle Graph Accuracy: Mainly test two cycles, then take the maximum value of the average value of the maximum speeds, so that the numerical accuracy is high. It is verified with standard sources, which is repeatable.

Open the catalog to page 6
Vascular Doppler Catalogue - 7

Comparison of Healthy & Unhealthy Reference Graph Healthy Blood Flow Graph Unhealthy Blood Flow Graphes

Open the catalog to page 7
Vascular Doppler Catalogue - 9

BV-520 • 8Mhz Probe, non-slip design • A LED bar to indicate the blood flow intensity,result is intuitive and visual. • Built-in rechargeable lithium battery, matched with adaptive AC power adapter for power supply; • Built-in high-quality speakers, clear blood flow sound; • Hand-held instrument, small size, practical and convenient. • Cost-effective, buy it once, at least 10 years of use • ISO13485 ISO9001 CE Certifica

Open the catalog to page 9
Vascular Doppler Catalogue - 10

• 9Mhz flat probe, converted to animal design, high accuracy; • The bar-shaped LED cursor indicates the blood flow intensity, which is intuitive and visible; • Built-in rechargeable lithium battery, matched with adaptive AC power adapter for power supply; • Built-in high-quality speakers, clear blood flow sound; • Hand-held instrument, small size, easy to use • Mainly used for the detection of animal arteries and capillary blood flow conditions; suitable for orthopedics, surgery, plastic surgery, burns, pet clinics, pet hospitals, etc.

Open the catalog to page 10
Vascular Doppler Catalogue - 11

BV-520TV+ • 9Mhz flat probe, converted to animal design; • 2.4-inch TFT LCD displays real-time average blood flow peak velocity and waveform; • Built-in rechargeable lithium battery, matched with adaptive AC power adapter for power supply; • Built-in high-quality speakers, clear blood flow sound; • The data can be transmitted to the PC through the USB port; • Hand-held instrument, small size, easy to use;

Open the catalog to page 11
Vascular Doppler Catalogue - 12

BV-520T • 8.0Mhz single and two-way blood flow probe assists doctors in detecting the blood flow of human arteries/venous vessels; • 2.4-inch TFT LCD displays real-time average blood flow peak velocity and waveform; • Working mode: continuous ultrasound Doppler; • Built-in high-capacity rechargeable battery can meet the requirements of long-term work; • With dedicated PC software, data can be transferred to the computer; • There are two choices of one-way instrument and two-way instrument; BV-

Open the catalog to page 12
Vascular Doppler Catalogue - 13

BV-520T+ • 8.0Mhz two-way blood flow probe, synchronously detect the two-way arterial blood flow condition; • 2.4 Inches TFT LCD, can display two-way blood flow waveform, average blood flow speed, pulse rate value; • The direction, mode, frequency, time scale, waveform, data, etc. of the probe can be set; • Optional ultrasound Doppler two-way blood vessel analysis and diagnosis software; • Two-way blood flow and one-way blood flow curves are optional; the two-way display speed curve can be set to two modes, synthetic/separated mode and combined flow rate graph, which is convenient for...

Open the catalog to page 13
Vascular Doppler Catalogue - 14

BV-520P • 8.0Mhz two-way blood flow probe, synchronously detect the two-way arterial blood flow condition; • 2.4 Inches TFT LCD, can display two-way blood flow waveform, average blood flow velocity, pulse rate and blood viscosity; • The host has a built-in thermal printer and memory, which can be used for a large number of blood flow waveforms in the north of the village, and the saved data can be recalled at any time and the test data can be printed; • Built-in lithium battery environmentally friendly rechargeable battery pack and adaptive AC power adapter; • The direction, mode,...

Open the catalog to page 14
Vascular Doppler Catalogue - 15

BV-620VP 1.Detect the blood stream status of arterial/venous by 8.0 MHz, detect the blood flow average velocity, result of finger/toes and part of body‘s vein on operation ,pulse rate; 2.Display the waveform and the detecting result of the blood stream average velocity and the spectrum line; 3.LCD can display the instant blood flow average, wave form intensity and the detecting result of the blood stream synchronously; 4.Built-in rechargeable battery; 5.Built-in printer with high precision can print monitoring blood stream graphics synchronously; 6.RS-232 port can connect the unit with a...