1. Catalogs
  2. Shenzhen Witleaf Medical Electronics
  3. Blood Oxygen/ Blood Pressure Module NR01

Blood Oxygen/ Blood Pressure Module NR01

Blood Oxygen/ Blood Pressure  Module NR01

Blood Oxygen/ Blood Pressure Module NR01

Product catalog summary
Overview
The NR01 module is a dual-function device capable of measuring both blood pressure and blood oxygen levels. It provides real-time data on pulse oxygen saturation, pulse rate, and perfusion index, and includes monitoring for systolic, mean, and diastolic blood pressure. The module supports real-time transmission of pulse wave signals and status updates for hardware, software, and sensors. It offers two patient modes: adult and child, and features anti-motion interference and weak signal measurement capabilities. Additional functionalities include pressure calibration and leak detection.
Specifications
  • Power Supply: DC 12V±10% or DC 5V±5%
  • Power Consumption: DC 12V: ≤5W, DC 5V: ≤1W
  • Communication: TTL, USART
  • Operating Temperature: 10°C to 40°C (50°F to 104°F)
  • Storage Temperature: -20°C to 70°C (4°F to 158°F)
Measurement Ranges and Accuracy
  • SPO2: Range 0-100%, Accuracy ±2% (70%-100%), Resolution 1%
  • Pulse Rate (PR): Range 25-250 bpm, Accuracy ±2 bpm, Resolution 1 bpm
  • Perfusion Index (PI): Range 0-20%, Resolution 0.001%
  • Non-Invasive Blood Pressure (NIBP): Pressure Range 0-300 mmHg, Accuracy ±2 mmHg or ±1%, Resolution 1 mmHg
  • Systolic Range: Adult 40-270 mmHg, Pediatric 40-200 mmHg, Neonate 40-130 mmHg
  • Diastolic Range: Adult 10-210 mmHg, Pediatric 10-162 mmHg, Neonate 10-90 mmHg
  • Mean Range: Adult 20-130 mmHg, Pediatric 20-170 mmHg, Neonate 20-100 mmHg
  • Accuracy: Mean deviation <±5 mmHg, Standard deviation <8 mmHg
Contact Information
For further details, contact via email at [email protected] or visit the website at www.szwitleaf.com. Address: Building A-1201, Senyang High-tech Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China. Phone: +86 0755-21384132.
See more

Catalog excerpts

Blood Oxygen/ Blood Pressure  Module NR01-1

Blood Oxygen/ Blood Pressure Module NR01 NR01 two-in-one parameter measurement module can measure blood pressure and blood oxygen. Parameters such as pulse rate. Dimension :7 1 m m × 3 8 . 4 m m × 1 5 m m Real-time measurement of pulse oxygen saturation, pulse rate, and perfusion index. With monitoring function of systolic blood pressure, mean blood pressure, diastolic blood pressure and pulse rate parameters Real-time transmission of pulse wave signals based on infrared spectrum absorption. Real-time transmission of the module's working status, hardware status, software status and sensor status. Provides two patient modes: adult and child mode. It has the function of setting the average time of blood oxygen calculation parameters to obtain different response time of blood oxygen calculation parameters. Capable of anti-motion interference and weak signal measurement. Pressure calibration function: Continuously provide cuff pressure value to calibrate pressure accuracy. Leak detection function: detect whether the gas path is leaking. Excellent reliability For more information, please contact us: sales@szwitlea

 Open the catalog to page 1
Blood Oxygen/ Blood Pressure  Module NR01-2

Distolic Range Mean Range 0-300mmHg ±2mmHg or ±1% (Whichever is greater) 1mmHg Adult : 40–270mmHg Pediatric : 40–200mmHg Neonate : 40–130mmHg Adult : 10–210mmHg Pediatric:10–162mmHg Neonate:10–90mmHg Adult : 20–130mmHg Pediatric : 20–170mmHg Neonate : 20–100mmHg The mean deviation<±5mmHg The standard deviation<8mmHg Electical Specification Power supply * The data is subject to change without notice. Please refer to the manual for the contraindications and precautions Address:Building A-1201, Senyang High-tech Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China Tel:+86 0755-21384132...

 Open the catalog to page 2

All Shenzhen Witleaf Medical Electronics catalogs and technical brochures

  1. E10E12E15

    5  Pages

  2. L10L12L15

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.