The RICap CO2 Monitor is designed for continuous monitoring of end tidal CO2 concentration (EtCO2), Capnogram, and Respiration Rate (RR) in adult, pediatric, and infant patients. It is suitable for use in emergency and perioperative departments, during patient transport, and for both intubated and non-intubated patients. The device is splashproof, lightweight, and portable, making it ideal for rapid intervention by ALS and BLS providers.
Features
  • High accuracy CO2 measurement using dual-wavelength technology.
  • Splashproof and rugged design for harsh conditions.
  • Four buttons for easy settings adjustments, alarm pause, and power on/off.
  • Adjustable sweep speed and selectable units (mmHg, kPa, %).
  • Apnea detection and configurable alarms for various parameters.
  • Bluetooth connectivity for real-time data export.
  • Supports multiple languages including English, Italian, French, Hungarian, and Polish.
Specifications
  • Dimensions: 60 x 47 x 43 mm; Weight: ~80 g.
  • Operating temperature: -5 to 50ºC; Storage temperature: -30 to 70ºC.
  • Atmospheric pressure range: 70 - 120 kPa.
  • Display: Active OLED color graphic display with 65,000 colors.
  • Respiration Rate Range: 0~150 BPM with ±1 BPM accuracy.
  • CO2 Measurement Range: 0 to 99 mmHg, 0 to 9.9%, 0 to 9.9 kPa with ±(0.2% + 2% of reading) accuracy.
Power Specifications
  • Powered by two AAA batteries with a battery life of approximately 4 to 7 hours depending on the battery type.
Regulatory Compliance
  • CE certified and compliant with IEC and ISO standards.
Box Content
  • RICap capnograph, adult and neonate airway adapters, lanyard, and pouch.
See more

Catalog excerpts

Carbon dioxide monitor-1

RICap Rapid Intervention Capnograph High degree of protection Sound and light double alarm Overview RICap CO2 Monitor is intended to provide continuous moni- ambulances but even within the hospital. Splashproof, toring of end tidal CO2 concentration (EtCO2), Capnogram, lightweight and fitting in the palm of a hand, starting up Respiration Rate (RR) of adult, paediatric and infant patients. within seconds, it is an excellent device that can be used As a life saving device during Rapid Intervention, RICap finds directly by both ALS and BLS providers. its place in emergency departments just as much as in RICap waveform allows a quick evaluation of the patient perioperative departments, spot check for both intubated respiratory distress help healthcare personel for a rapide and non-intubated patients, and during transport not only in For more information, please contact us: [email protected]

 Open the catalog to page 1
Carbon dioxide monitor-2

Accuracy:Automatic compensation algorithm for temperature,atmospheric pressure and the patented Anti-condensing technology of the airway adapter to ensure the reliable of measurement results. Easy to Start up:Quick set up and one-touch programming without maintain request. Powered by two 3A batteries, real-time monitoring of equipment ≥4h Power On/Off Button Airway Adapter Alarm Slience Button Short press the " " button, RICap Alarm silence Infant Adult/Pediatric Configuration Parameter Display Press the ”^” button to configure RICap. Zero calibration Press and hold “^” “ ”together to trigger the...

 Open the catalog to page 2
Carbon dioxide monitor-3

Specifications Mechanical and Environment Feature Dimensions ~80 g (complete device with batteries), < 350grs with transport pouch. Mechanical robustness Meets the shock and vibration requirements for transport of SS-EN ISO 21647:2004 clause 21.102 Operating: -5 to 50ºC, 10 to 90% RH, non-condensing Storage: -30 to 70ºC, <90% RH, non-condensing EtCO2 Measurement Transducer Type Capnogram, displayed within few seconds at an ambient temperature of 25ºC, and full specifications within 1-2 minutes especially if temperature below 15ºC No routine user calibration required. An airway adapter zero is required...

 Open the catalog to page 3
Carbon dioxide monitor-4

Power Specifications External Supply Two AAA Cell batteries (2x1.5VDC): Alkaline IEC:LR03 or Energizer Ultimate Lithium L92 batteries. Use of other Lithium batteries may present a risk of fire or explosion Duracell Plus Alkaline: ~4 hours Energizer Ultimate Lithium L92: ~7 hours Regulatory Compliance Certificate Standards compliance RICap capnograph, adult and neonate airway adapters, lanyard and pouch Interfaaces Part Number Included with device RICap module Disposable Adult airway adapter Reusable Neonate airway adapter * The data is subject to change without notice. Please refer to the manual...