Catalog excerpts
L10M/L12M/L15M Series Animal Monitor Animal condition in one glance 10.0 inch Touch Screen Intelligent Setting Easy Clean More Readable Overview L10M/L12M/L15M series of veterinary monitors are independently developed and manufactured by Witleaf Medical company, based on a large number of clinical studies on veterinary monitoring, designing veterinary-specific system solutions and algorithmic systems, which are widely used in veterinary monitoring and surgery. For more information, please contact us: sales@szwitleaf.com
Open the catalog to page 1Features Excellent Performance : > LowPulseStrTM SpO2 algorithm provides more reliable SpO2 readings during low perfusion and exercise ; > iFastBP® NIBP algorithm for fast and comfortable measurements ; > wSmartHeart ® ECG technology for safer animal monitoring ; > wSmartGas® Capnograph technology for reliable readings in multiple environments . Powerful function : > Multi display mode other beds view/Big font ; > 10,12,15inch screen can be optional ; > Wifi connectivity more flexible application ; > Smart alarm system more safety and more efficient ; > Fanless design . Patented CapnoSET and...
Open the catalog to page 2Product Optional Guider Standard application Optional application Central monitor Touch Screen Product Specifications GENERAL SPO2 ◆ SPO2 Range: 0~100% ◆ SPO2 Accuracy : 70~100%,±2% <69%,Undefined ◆ PI Range : 0~20% ◆ PVI Range : 0.001% ◆ PR Range : 25-350bpm ◆ PR Ac
Open the catalog to page 3♦ ECG Range : 0.15~5.5mV ♦ ECG Resolution : 2.36uV/LSB ♦ HR Range : 15~350bpm ♦ HR Accuracy : ±1bpm or ±1% (whichone is greater) ♦ RR Range : 0~120bpm ♦ RR Accuracy : 15~120rpm : ±2rpm or ±2% <15rpm:Undefined ♦ Pressure Range ♦ Pressure Accuracy ♦ Resolution ♦ SYS Range ♦ DIA Range ♦ Mean Range ♦ Accuracy 0~300mmHg ±2mmHg or ±1% of reading (take the larger value) 1mmHg Large animal : 40-270mmHg Medium animal : 40-235mmHg Small animal : 25-130mmHg Large animal : 10-210mmHg Medium animal : 10-180mmHg Small animal : 10-90mmHg Large animal : 20-230mmHg Medium animal : 20-200mmHg Small animal :...
Open the catalog to page 4♦ PR Accuracy ±2bpm or ±2% (whichone is greater) EtCO2 (Optional) ♦ CO2 Range ♦ CO2 Accuracy ♦ AwRR Range ♦ AwRR Accuracy * The data is subject to change without notice. Please refer to the manual for the contraindications and precautions Address: Building A-1201, Senyang High-tech Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China Tel: +86 0755-21384132 Email :sales@szwitleaf.com Web:www.szwitleaf.com
Open the catalog to page 5All Shenzhen Witleaf Medical Electronics catalogs and technical brochures
-
M701 EEG module
5 Pages
-
W12/W15 Series
6 Pages
-
VS1000 patient monitor
5 Pages
-
XH-80 Patient Monitor
6 Pages
-
E10E12E15
5 Pages
-
L10L12L15
5 Pages
-
XH-60 Vital Signs Monitor
4 Pages
-
Carbon dioxide monitor
4 Pages
-
WITLEAF OEM Solutions Catalog
16 Pages
-
Multi-parameter Module M001
2 Pages
-
Multi-parameter Module M011
2 Pages
-
Multi-parameter Module M103
2 Pages
-
12 Leads ECG Module M108
2 Pages
-
3/5 Leads ECG Module M101
2 Pages
-
CapnoSET CO2 Sensor
2 Pages
-
Multi Parameter Patient Monitor
17 Pages