Multi-parameter Module M001

Multi-parameter Module M001

Multi-parameter Module M001

Product catalog summary
Overview
The Multi-parameter Module M001 is a compact medical monitoring device with dimensions of 140mm x 85mm x 25mm. It is designed to monitor various vital signs including pulse oxygen, pulse rate, systolic and diastolic blood pressure, mean pressure, ECG, respiration, and body temperature. The module supports three patient modes: adult, child, and newborn.

Key Features
  • Integrated blood pressure gas circuit system, eliminating the need for tracheal connection.
  • Real-time transmission module with hardware, software, and sensor status monitoring.
  • Accurate blood oxygen monitoring even at low perfusion index (0.075%).
  • Advanced algorithms for blood oxygen and blood pressure to reduce motion interference and improve weak signal measurement.
  • Three modes for blood pressure measurement: manual, automatic, and continuous.
  • Dual overvoltage protection and double timeout protection for blood pressure measurement.
  • ECG measurement includes heart rate, body temperature, respiration, ST segment offset values, and arrhythmia results with 18 analysis functions.

Specifications
  • Power Supply: DC 12V±5%
  • Power Consumption: ≤6W
  • Communication: TTL, USART
  • Operating Temperature: 10°C to 40°C
  • Storage Temperature: -20°C to 70°C

Compliance
  • Standards: IEC 60601-2-25-2011, IEC 60601-2-30-1996-A1:1999, EN 1060-1-1995, EN1060-3-1997, ISO 80601-2-61:2011, AAMI EC57-2012

Measurement Ranges and Accuracy
  • ECG: Range 0.15Mv-5.5mV, Resolution 2.36uV/LSB
  • Heart Rate: Adult 15-300bpm, Child/Newborn 15-350bpm, Accuracy ±1bpm
  • Respiration Rate: 0-120rpm, Accuracy ±2rpm or ±2%
  • NIBP: Pressure Range 0-300mmHg, Accuracy ±2mmHg or ±1%
  • Pulse Rate: Range 25-250bpm, Accuracy ±2bpm
  • Temperature: Range 0-50°C, Accuracy ±0.1°C
  • SPO2: Range 0-100%, Accuracy ±2% (70%-100%)

Contact Information
Address: Building A-1201, Senyang High-tech Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China
Website: www.szwitleaf.com
Tel: +86 0755-21384132
Email: [email protected]

Note: Data is subject to change without notice. Refer to the manual for contraindications and precautions.
See more

Catalog excerpts

Multi-parameter Module M001-1

Multi-parameter Module M001 It is used to monitor the patient's blood oxygen, blood pressure, electrocardiogram, respiration, body temperature, heart rate, and pulse Features > With pulse oxygen, pulse rate monitoring function. > With monitoring function of systolic blood pressure, diastolic blood pressure and mean pressure. > With 3/5 lead ECG, 1 breathing, 2 body temperature monitoring functions. > Provide three patient modes: adult, child and newborn mode. > Module thickness is only 25mm, exquisite and compact. > Integrated blood pressure gas circuit system design, no need for tracheal connection. > The working status of the real-time transmission module: hardware status, software status and sensor status, the upper computer can alarm in time according to the information. > When the perfusion index is as low as 0.075%, the blood oxygen monitoring is accurate and reliable, meeting the application of surgery and ICU. > Both blood oxygen and blood pressure adopt advanced algorithms, with anti-motion interference and weak signal measurement performance. > Blood pressure measurement has three modes: manual, automatic and continuous mode. > Blood pressure measurement has hardware and software dual overvoltage protection functions. > Double timeout protection for blood pressure measurement (module timeout protection, provide timing trigger port of host computer). > The measurement results of the ECG measurement part include heart rate, body temperature, respiration, ST segment offset values of I, II, and V1 channels, and arrhythmia results. > ECG measurement has diagnosis, monitoring, HARDEST and surgery modes. > Has 18 arrhythmia analysis functions. For more information, please contact us: sales@szwitleaf

 Open the catalog to page 1
Multi-parameter Module M001-2

Range Accuracy Resolution lead type Range Accuracy 0.15Mv-5.5mV Undefined 2.36uV/LSB 3 Lead:I or IIor III 5Lead:I ,II,III,AVR,AVL,AVF,V1 Range Accuracy Resolution Accuracy Resolution Pressure Range 0-300mmHg Pressure Accuracy ±2mmHg or ±1% (Whichever is greater) Resolution 1mmHg Systolic Range Adult : 40–270mmHg Pediatric : 40–200mmHg Neonate : 40–130mmHg Distolic Range Adult : 10–210mmHg Pediatric:10–162mmHg Neonate:10–90mmHg Mean Range Adult : 20–230mmHg Pediatric : 20–170mmHg Neonate : 20–100mmHg Accuracy The mean deviation<±5mmHg The standard deviation<8mmHg Range Accuracy Resolution Electical...

 Open the catalog to page 2

All Shenzhen Witleaf Medical Electronics catalogs and technical brochures

  1. E10E12E15

    5  Pages

  2. L10L12L15

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.