Catalog excerpts
Multi-parameter Module M001 It is used to monitor the patient's blood oxygen, blood pressure, electrocardiogram, respiration, body temperature, heart rate, and pulse Features > With pulse oxygen, pulse rate monitoring function. > With monitoring function of systolic blood pressure, diastolic blood pressure and mean pressure. > With 3/5 lead ECG, 1 breathing, 2 body temperature monitoring functions. > Provide three patient modes: adult, child and newborn mode. > Module thickness is only 25mm, exquisite and compact. > Integrated blood pressure gas circuit system design, no need for tracheal connection. > The working status of the real-time transmission module: hardware status, software status and sensor status, the upper computer can alarm in time according to the information. > When the perfusion index is as low as 0.075%, the blood oxygen monitoring is accurate and reliable, meeting the application of surgery and ICU. > Both blood oxygen and blood pressure adopt advanced algorithms, with anti-motion interference and weak signal measurement performance. > Blood pressure measurement has three modes: manual, automatic and continuous mode. > Blood pressure measurement has hardware and software dual overvoltage protection functions. > Double timeout protection for blood pressure measurement (module timeout protection, provide timing trigger port of host computer). > The measurement results of the ECG measurement part include heart rate, body temperature, respiration, ST segment offset values of I, II, and V1 channels, and arrhythmia results. > ECG measurement has diagnosis, monitoring, HARDEST and surgery modes. > Has 18 arrhythmia analysis functions. For more information, please contact us: sales@szwitleaf
Open the catalog to page 1Range Accuracy Resolution lead type Range Accuracy 0.15Mv-5.5mV Undefined 2.36uV/LSB 3 Lead:I or IIor III 5Lead:I ,II,III,AVR,AVL,AVF,V1 Range Accuracy Resolution Accuracy Resolution Pressure Range 0-300mmHg Pressure Accuracy ±2mmHg or ±1% (Whichever is greater) Resolution 1mmHg Systolic Range Adult : 40–270mmHg Pediatric : 40–200mmHg Neonate : 40–130mmHg Distolic Range Adult : 10–210mmHg Pediatric:10–162mmHg Neonate:10–90mmHg Mean Range Adult : 20–230mmHg Pediatric : 20–170mmHg Neonate : 20–100mmHg Accuracy The mean deviation<±5mmHg The standard deviation<8mmHg Range Accuracy Resolution...
Open the catalog to page 2All Shenzhen Witleaf Medical Electronics catalogs and technical brochures
-
M701 EEG module
5 Pages
-
W12/W15 Series
6 Pages
-
VS1000 patient monitor
5 Pages
-
XH-80 Patient Monitor
6 Pages
-
E10E12E15
5 Pages
-
L10L12L15
5 Pages
-
XH-60 Vital Signs Monitor
4 Pages
-
Carbon dioxide monitor
4 Pages
-
WITLEAF OEM Solutions Catalog
16 Pages
-
Multi-parameter Module M011
2 Pages
-
Multi-parameter Module M103
2 Pages
-
12 Leads ECG Module M108
2 Pages
-
3/5 Leads ECG Module M101
2 Pages
-
CapnoSET CO2 Sensor
2 Pages
-
Multi Parameter Patient Monitor
17 Pages