Multi-parameter Module M103
2Pages

{{requestButtons}}

Catalog excerpts

Multi-parameter Module M103 - 1

Multi-parameter Module M103 It is used to monitor the patient's blood oxygen, blood pressure, electrocardiogram, respiration, body temperature, heart rate, and pulse With pulse oxygen and pulse rate monitoring function With monitoring function of systolic blood pressure, diastolic blood pressure and mean pressure With 12-lead ECG, 3/5-lead ECG, 1 breathing, 2 body temperature monitoring functions Provide three patient modes: adult, child and newborn mode The module thickness is only 25mm, exquisite and compact Design of integrated blood pressure airway system The working status of the real-time transmission module: hardware status, software status and sensor status, the upper computer can alarm in time according to the information > When the perfusion index is as low as 0.075%, the blood oxygen monitoring is accurate and reliable, meeting the application of surgery and ICU > Both blood oxygen and blood pressure adopt advanced algorithms, with anti-motion interference and weak signal measurement performance > Blood pressure measurement has three modes: manual, automatic and continuous mode > Blood pressure measurement has hardware and software dual overvoltage protection functions > Double timeout protection for blood pressure measurement (module timeout protection, provide timing trigger port of host computer) > The measurement results of the ECG measurement part include heart rate, body temperature, respiration and ST segment off set values of I, II, and V1 channels > ECG measurement has diagnosis, monitoring, HARDEST and surgery modes > ECG diagnostic analysis results include arrhythmia, conduction block, myocardial infarction, STT changes, ventricular hypertrophy, atrial enlargement, electrical axis deviation and other heart diseases For more information, please contact us: sales@szwitleaf

Open the catalog to page 1
Multi-parameter Module M103 - 2

Range Accuracy Resolution lead type Range Accuracy Range Accuracy Resolution Accuracy Resolution Pressure Range 0-300mmHg Pressure Accuracy ±2mmHg or ±1% (Whichever is greater) Resolution 1mmHg Systolic Range Adult : 40–270mmHg Pediatric : 40–200mmHg Neonate : 40–130mmHg Distolic Range Adult : 10–210mmHg Pediatric:10–162mmHg Neonate:10–90mmHg Mean Range Adult : 20–130mmHg Pediatric : 20–170mmHg Neonate : 20–100mmHg Accuracy The mean deviation<±5mmHg The standard deviation<8mmHg Range Accuracy Resolution Electical Specification Power supply Compliance Standard * The data is subject to change...

Open the catalog to page 2

All Shenzhen Witleaf Medical Electronics catalogs and technical brochures

  1. E10E12E15

    5 Pages

  2. L10L12L15

    5 Pages