NEW XH-60 Vital Signs Monitor
1 /6Pages

NEW XH-60 Vital Signs Monitor

NEW XH-60 Vital Signs Monitor
1 /6Pages

Catalog excerpts

NEW XH-60 Vital Signs Monitor-1

XH-60S series Patient Monitor Prime Innovation for Medical Application Overview XH-60S series Patient monitor has been designed to serve frontline caregivers in emergency, perioperative care and ICU/NICU departments. With its accurate oximetry adapted for adult as well as neonate, it provides a continuous and accurate monitoring of the SpO2 and PR even in case of low perfusion. Connectivity Ability Its handle and lightweight make it easy for trans port use while its 4 stable feet allow a reliable use as bedside monitor. Cost effective, it remains a comprehensive device for multiple applications and environments. Historical Management For more information, please contact us: [email protected] Powerful Parameter Measurement

 Open the catalog to page 1
NEW XH-60 Vital Signs Monitor-2

Multi-scenario application Operating room Out-of-hospital emergency Transport hospital Features Equipped with high-performance blood oxygen, blood pressure, end-respiratory carbon dioxide module technology independently developed by witleaf RS232 serial port data transmission function . Small and easy to use, easy to carry, ideal for surgery, emergency, physical examination, social health and other environments Equipped with a built-in rechargeable lithium battery to meet the needs of medical visits and emergency vehicles It is equiped with a 5' TFT display and the display panel is inclined at...

 Open the catalog to page 2
NEW XH-60 Vital Signs Monitor-3

Vital Signs at a giance Accuracy: ±1rpm(0~70rpm)Undefined(wihin other ranges) Accuracy: ±2bpm or ±2% (whichever is greater)

 Open the catalog to page 3
NEW XH-60 Vital Signs Monitor-4

Method: Automatic oscillometric Operation modes: Manual, Automatic, Continuous Automatic mode measurement interval: 1min/2min/3min/4min/5min/10min/15min/30min/60min/90min/2h/3h Continuous mode measurement period: 5mins, with 5s between each measurement Maximum single measurement time: <120s Measurement range: Systolic BP: Adult mode: 40 ~ 270 mmHg, Pediatric mode: 40 ~ 200 mmHg, Diastolic BP: Adult mode: 10 ~ 210 mmHg, Pediatric mode: 10 ~ 162 mmHg, MAP: Adult mode: 20 ~ 230 mmHg, Pediatric mode: 20 ~ 175 mmHg Accuracy: Mean error: <±5mmHg, Standard deviation: <8mmHg Static pressure measurement...

 Open the catalog to page 4
NEW XH-60 Vital Signs Monitor-5

Compliance Standards Optional : 6 models of configuration options Audio/Visual Indicators: Alarm limit reached, Alarm tone, Alarm mute, pulse • RS232 interface • Connected to central monitor via RJ45 . • Bluetooth Printer • Ethernet Port strength, Patient name, Patient Type, Time, battery status, connection status. • LEDs: Adult, Neonate, Pressure Unit or SpO2/PR (according to model), battery in use, battery charging, silenced alarm. • User Interface language: English (additional language upon request). Ordering Descrlptions Optional non contact infrared Fast TEMP probe with cable Optional Bluetooth...

 Open the catalog to page 5
NEW XH-60 Vital Signs Monitor-6

Software copyright patent * The data is subject to change without notice. Please refer to the manual for the contraindications and precautions Address: Building A-1201, Senyang High-tech Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China Tel:+86 0755-21384132 Email:[email protected] Web:www.szwitlea

 Open the catalog to page 6