Overview
The M201B module is designed for monitoring pulse oximetry, pulse, and perfusion index, with additional 3-lead ECG monitoring capabilities. It supports patient models including adults, pediatrics, and newborns, and offers 26 arrhythmia analysis functions verified by MIT and AHA databases, compliant with EC57 standardized tests.
Measurement Modes
  • Diagnosis Mode: Filter range of 0.05Hz to 130Hz.
  • Monitoring Mode: Filter range of 0.5Hz to 40Hz.
  • HARDEST Mode: Filter range of 5Hz to 20Hz.
  • Surgery Mode: Filter range of 1Hz to 25Hz.
ECG Features
  • ECG calibration with 1mV standard voltage input.
  • Adjustable ECG waveform amplitude (Gain setting).
  • Notch mode options: 50Hz, 60Hz, 50/60Hz, and off.
Specifications
  • Dimensions: 88.9mm x 50.8mm x 7mm.
  • Power Supply: DC 12V±5%.
  • Power Consumption: ≤3W.
  • Communication: TTL, USART.
  • Operating Temperature: 10°C to 40°C (50°F to 104°F).
  • Storage Temperature: -20°C to 70°C (4°F to 158°F).
Compliance and Standards
  • IEC 80601-2-61:2011
  • IEC 60601-1-2
Measurement Specifications
  • SPO2: Range 0-100%, Accuracy ±2% (70%-100%), Resolution 1%.
  • PR: Range 25-250bpm, Accuracy ±2bpm, Resolution 1bpm.
  • PI: Range 0-20%, Resolution 0.001%.
  • PVI: Range 100%, Resolution 1%.
Contact Information
For further details, contact [email protected] or visit www.szwitleaf.com. Address: Building A-1201, Senyang High-tech Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China. Tel: +86 0755-21384132.
See more

Catalog excerpts

Pulse Arterial Oxygen Saturation Module M201B-1

Pulse Arterial Oxygen Saturation Module M201B The M201B module is used to monitor the patient's pulse oximetry, pulse, and perfusion index Dimension :8 8 . 9 m m × 5 0 . 8 m m × 7 m m With 3-lead ECG monitoring function Patient model: adult, pediatric and newborn 26 arrhythmia analysis functions, verified by MIT and AHA databases, and passed EC57 standardized tests Provides four measurement modes: diagnosis, monitoring, HARDEST and surgery mode Diagnosis mode: filter range is 0.05hz~130hz Monitoring mode: filter range is 0.5hz~40hz HARDEST mode: the filtering range is 5hz~20hz Surgery mode: filter range is 1hz~25hz ECG calibration: input 1mv standard voltage to record the waveform amplitude Gain setting: adjust the amplitude of the ECG waveform Notch mode: 50Hz, 60Hz, 50/60Hz and close notch mode commands can be selected For more information, please contact us: sales@sz

 Open the catalog to page 1
Pulse Arterial Oxygen Saturation Module M201B-2

Accuracy: Undefined Accuracy: Undefined Electical Specification Power supply Compliance Standard * The data is subject to change without notice. Please refer to the manual for the contraindications and precautions Address:Building A-1201, Senyang High-tech Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China Tel:+86 0755-21384132 Email:sales@szwitleaf

 Open the catalog to page 2

All Shenzhen Witleaf Medical Electronics catalogs and technical brochures

  1. E10E12E15

    5  Pages

  2. L10L12L15

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.