Overview: The Pulse Arterial Oxygen Saturation Module M201D is designed for monitoring pulse oximetry, pulse, and perfusion index in adults, children, and newborns. It features real-time transmission of hardware, software, and sensor status, and includes advanced anti-motion algorithms for accurate measurements even at low perfusion indices.
Specifications:
  • Dimensions: 51mm x 38.1mm x 7mm
  • Power Supply: DC 5V±5%
  • Power Consumption: ≤3W
  • Communication: TTL, USART
  • Operating Temperature: 10°C to 40°C (50°F to 104°F)
  • Storage Temperature: -20°C to 70°C (4°F to 158°F)
Measurement Ranges and Accuracy:
  • SPO2: Range 0-100%, Accuracy ±2% (70%-100%), Resolution 1%
  • Pulse Rate (PR): Range 25-250 bpm, Accuracy ±2 bpm, Resolution 1 bpm
  • Perfusion Index (PI): Range 0-20%, Resolution 0.001%
  • Perfusion Variation Index (PVI): Range 100%, Resolution 1%
Standards and Compliance: The module complies with IEC 80601-2-61:2011 and IEC 60601-1-2 standards.
Additional Information: For further details, contact [email protected] or visit www.szwitleaf.com. The data is subject to change without notice, and users should refer to the manual for contraindications and precautions.
See more

Catalog excerpts

Pulse Arterial Oxygen Saturation Module M201D-1

Pulse Arterial Oxygen Saturation Module M201D The M201D module is used to monitor the patient's pulse oximetry, pulse, and perfusion index Dimension :5 1 m m × 3 8 . 1 m m × 7 m m With the monitoring function of pulse oxygen, pulse rate, perfusion index and variation index Patient model: adult, child and newborn Real-time transmission module working status: hardware status, software status and sensor status It has the function of setting the average time of calculation parameters, and obtains the response time of different calculation parameters When the blood perfusion index is as low as 0.075%, the measurement is accurate and reliable, which can meet the application of surgery and ICU Adopt advanced anti-motion algorithm, with strong anti-motion performance For more information, please contact us: sales@szwitleaf.

 Open the catalog to page 1
Pulse Arterial Oxygen Saturation Module M201D-2

Accuracy: Undefined Accuracy: Undefined Electical Specification Power supply Compliance Standard * The data is subject to change without notice. Please refer to the manual for the contraindications and precautions Address:Building A-1201, Senyang High-tech Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China Tel:+86 0755-21384132 Email:sales@szwitleaf