Product catalog summary
Overview
The M201U module is designed for monitoring pulse oximetry, pulse rate, perfusion index, and variation index in patients, including adults, children, and newborns. It provides real-time transmission of hardware, software, and sensor status.

Measurement Method
The module uses absorption of 660 and 905 nanometer red and infrared light by pulsatile blood. A photoelectric sensor captures these signals, which are then amplified, filtered, digitized, and processed to determine oxygen saturation and pulse rate.

Specifications
  • Power Supply: DC 5 V±5%
  • Power Consumption: ≤3W
  • Communication: TTL, USART
  • Operating Temperature: 10°C to 40°C (50°F to 104°F)
  • Storage Temperature: -20°C to 70°C (4°F to 158°F)

Measurement Ranges and Accuracy
  • SPO2: Range 0-100%, Accuracy ±2% (70%-100%), Resolution 1%
  • Pulse Rate (PR): Range 25-250 bpm, Accuracy ±2 bpm, Resolution 1 bpm
  • Perfusion Index (PI): Range 0-20%, Resolution 0.001%
  • Perfusion Variation Index (PVI): Range 100%, Resolution 1%

Standards and Compliance
The module complies with IEC 80601-2-61:2011 and IEC 60601-1-2 standards.

Contact Information
For more details, contact [email protected] or visit www.szwitleaf.com. Address: Building A-1201, Senyang High-tech Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China. Tel: +86 0755-21384132.
See more

Catalog excerpts

Pulse Arterial Oxygen Saturation Module M201U-1

Pulse Arterial Oxygen Saturation Module M201U The M201U module is used to monitor the patient's pulse oximetry, pulse, and perfusion index With the monitoring function of pulse oxygen, pulse rate, perfusion index and variation index Patient model: adult, child and newborn Real-time transmission module working status: hardware status, software status and sensor status It has the function of setting the average time of calculation parameters, and obtains the response time of different calculation parameters The measurement method is based on the absorption of pulsed 660 and 905 nanometer red light and infrared spectra by pulsatile blood, and the photoelectric sensor receives the red light and infrared light signal transmitted through the finger, and then transmits it to the photocurrent signal amplifier, and then passes it to the photocurrent signal amplifier. Voltage amplification, filtering, digitization, feature recognition and algorithms are processed to obtain measurement results of related parameters such as oxygen saturation and pulse rate. For more information, please contact us: sales@s

 Open the catalog to page 1
Pulse Arterial Oxygen Saturation Module M201U-2

Accuracy: Undefined Accuracy: Undefined Electical Specification Power supply Compliance Standard * The data is subject to change without notice. Please refer to the manual for the contraindications and precautions Address:Building A-1201, Senyang High-tech Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China Tel:+86 0755-21384132 Email:sales@szwitleaf

 Open the catalog to page 2

All Shenzhen Witleaf Medical Electronics catalogs and technical brochures

  1. E10E12E15

    5  Pages

  2. L10L12L15

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.