Single Leads ECG Module M101C

Single Leads ECG Module M101C

Single Leads ECG Module M101C

Product catalog summary
Overview
The document provides technical specifications and features of the Single Lead ECG Module M101C, designed for patient monitoring across adult, pediatric, and newborn models. It includes arrhythmia analysis functions verified by MIT and AHA databases and complies with the EC57 standardized tests.
Features
  • Dimensions: 77mm x 53mm x 17mm
  • 3-lead ECG monitoring function
  • 26 arrhythmia analysis functions
  • Four measurement modes: Diagnosis, Monitoring, HARDEST, and Surgery
  • ECG calibration and gain setting capabilities
  • Notch mode options: 50Hz, 60Hz, 50/60Hz, and off
Specifications
  • ECG Algorithm
  • Power Supply: DC 5V±5%
  • Power Consumption: ≤3W
  • Communication: TTL, USART
  • Operating Temperature: 10°C to 40°C (50°F to 104°F)
  • Storage Temperature: -20°C to 70°C (4°F to 158°F)
Electrical Specifications
  • ECG Range: 0.15mV-5.5mV
  • Resolution: 2.36uV/LSB
  • Lead Type: 3 Lead (I, II, or III)
  • Heart Rate Range: 15-300bpm
  • Heart Rate Accuracy: ±1bpm
  • Standards: AAMI EC57-2012, IEC60601-2-25-2011
Database Performance
  • Sensitivity of QRS wave detection: 99.60% (MIT), 99.66% (AHA)
  • Sensitivity of room early detection: 99.72% (MIT), 99.91% (AHA)
  • Early detection accuracy rate: 92.0% (MIT), 90.0% (AHA)
  • False positive rate of early detection: 92.5% (MIT), 89.31% (AHA)
  • Positive predictive degree of QRS complex detection: 0.52% (MIT), 0.638% (AHA)
Compliance and Contact Information
The data is subject to change without notice. For contraindications and precautions, refer to the manual. Contact information includes an address in Shenzhen, China, a website, telephone number, and email for sales inquiries.
See more

Catalog excerpts

Single Leads ECG Module M101C-1

Single Leads ECG Module M101C The M101C single-lead ECG measurement module can measure ECG and is used in patient monitoring. Dimension :7 7 m m × 5 3 m m × 1 7 m m With 3-lead ECG monitoring function Patient model: adult, pediatric and newborn 26 arrhythmia analysis functions, verified by MIT and AHA databases, and passed EC57 standardized tests Provides four measurement modes: diagnosis, monitoring, HARDEST and surgery mode Diagnosis mode: filter range is 0.05hz~130hz Monitoring mode: filter range is 0.5hz~40hz HARDEST mode: the filtering range is 5hz~20hz Surgery mode: filter range is 1hz~25hz ECG calibration: input 1mv standard voltage to record the waveform amplitude Gain setting: adjust the amplitude of the ECG waveform Notch mode: 50Hz, 60Hz, 50/60Hz and close notch mode commands can be selected For more information, please contact us: sales@sz

 Open the catalog to page 1
Single Leads ECG Module M101C-2

lead type Electical Specification Power supply Power consumption Compliance Standard Sensitivity of QRS wave detection/ Q Se Positive predictive degree of QRS complex detection/Q +P Sensitivity of room early detection/ V Se Early detection accuracy rate /V +P False positive rate of early detection /V FPR * The data is subject to change without notice. Please refer to the manual for the contraindications and precautions Address:Building A-1201, Senyang High-tech Park, Yutang Street, Guangming District, Shenzhen, Guangdong, China Tel:+86 0755-21384132 Email:[email protected]

 Open the catalog to page 2

All Shenzhen Witleaf Medical Electronics catalogs and technical brochures

  1. E10E12E15

    5  Pages

  2. L10L12L15

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.