W12M/W15M Modular Veterinary Monitoring
5Pages

{{requestButtons}}

Catalog excerpts

W12M/W15M Modular Veterinary Monitoring - 1

W12M/W15M Series Animal Monitor Animal condition in one glance 12.1 inch Overview The W12M/W15M high-end animal-specific modular monitor is designed to meet the growing demand for animal healthcare, modular customization, and diverse clinical applications, allowing the animal world to enjoy high-end life care. Intelligent Setting For more information, please contact us: sales@szwitleaf.com Touch Screen

Open the catalog to page 1
W12M/W15M Modular Veterinary Monitoring - 2

Features Dedicated veterinary algorithm: > LowPulseStrTM SPO2 algorithm more reliable readings of SPO2 during low perfusion and motion. > iFastBP® NIBP algorithm used for fast and comfortable measurement. wSmartHeart® ECG technology for more safey monitoring of patient. wSmartGas® Capnograph technology to get reliable reading during multi-environment. Powerful function > Plug-in module, multiple parameters available. > 12.1,15.6 inch screen can be optional. > Wifi connectivity more flexible application. > eTeleViewTM Central Montior system support. > Smart alarm system more safety and more...

Open the catalog to page 2
W12M/W15M Modular Veterinary Monitoring - 3

Plug-in Modular Product Optional Guider Standard application Optional application EtCO2(Main stream , Side stream , TiniStream), Central monitor Touch Screen Product Specifications GENERAL

Open the catalog to page 3
W12M/W15M Modular Veterinary Monitoring - 4

SPO2 ♦ SPO2 Range : 0~100% ♦ SPO2 Accuracy : 70~100%,±2% <69%,Undefined ♦ PI Range : 0~20% ♦ PVI Range : 0.001% ♦ PR Range : 25-350bpm ♦ PR Accuracy : ±3bpm ECG ♦ ECG Range : 0.15~5.5mV ♦ ECG Resolution : 2.36uV/LSB ♦ HR Range : 15~350bpm ♦ HR Accuracy : ±1bpm or ±1% (whichone is greater) ♦ RR Range : 0~120bpm ♦ RR Accuracy : 15~120rpm : ±2rpm or ±2% <15rpm:Undefined ♦ Pressure Range : 0~300mmHg ♦ Pressure Accuracy : ±2mmHg or ±1% of reading (take the larger value) ♦ Resolution : 1mmHg ♦ SYS Range : Large animal : 40-270mmHg ♦ DIA Range : Large animal : 10-210mmHg ♦ Mean Range : Large...

Open the catalog to page 4
W12M/W15M Modular Veterinary Monitoring - 5

TEMP ♦ Range : 0-50°C ♦ Accuracy : ±0.1°C ♦ Resolution : 0.1°C RESP ♦ Range : 0-120Rpm ♦ Accuracy : 15-120Rpm ±2Rpm or ±2% of the reading (which one is larger) Others,undefined ♦ Resolution : 1Rpm IBP(Optional) ♦ Pressure Range : -50~400mmHg ♦ Accuracy : ±3mmHg or ±1% of reading ♦ PR Range : 25-250bpm ♦ PR Accuracy : ±2bpm or ±2% (whichone is greater) CO(Optional) ♦ Range : 0.20~20.00L/Min ♦ Accuracy : ±5% EtCO2 (Optional) ♦ CO2 Range : 0~20.0vol% ♦ CO2 Accuracy : 0~12vol% : ±(0.2vol%+2%of reading) 12.1~20vol% : ±(0.2vol%+6%of reading) ♦ AwRR Range : 0~150rpm ♦ AwRR Accuracy : mainstream :...

Open the catalog to page 5

All Shenzhen Witleaf Medical Electronics catalogs and technical brochures

  1. E10E12E15

    5 Pages

  2. L10L12L15

    5 Pages