WITLEAF OEM Solutions Catalog
16Pages

{{requestButtons}}

Catalog excerpts

WITLEAF OEM Solutions Catalog - 1

WITLEAF GLOBAL DISTRIBUTION France Antibes, North America ChangSha,NanJing,BeiJing,ShenZhen North America France Antibes SHENZHEN HEADQUARTERS Shenzhen Witleaf Medical Electronics Co., Ltd 13/F-B2, Block 1, Senyang Science Park, No.7 Road, West district of High-tech park, Guangming District,Shenzhen City,GuangDong,China. TEL: +86) ( 0755-21384132 Email:sales@szwitleaf.com WITLEAF OEM Solutions Advanced OEM Module

Open the catalog to page 1
WITLEAF OEM Solutions Catalog - 2

ABOUT US Shenzhen WITLEAF Medical Electronics Co., Ltd. was vision “Build Health Scale,Measure Life Quality” Patient safety and positive patient outcomes drive Single Lead ECG Module M101C Pulse Arterial oxygen saturation Module M201B Pulse Arterial oxygen saturation Module M201D Pulse Arterial oxygen saturation Module M201U Non-invasive Blood pressure Module M301 External Pulse Oximetry cable SatEx Capnography monitoring solutions Invasive Blood Pressure Cardiac Output M601 4-Channel Invasive Blood Pressure M603 established in 2013.It is a high-tech company that develops, produces and...

Open the catalog to page 2
WITLEAF OEM Solutions Catalog - 3

It is used to monitor the patient's blood oxygen, blood pressure, electrocardiogram, respiration, body temperature, heart rate, and pulse Range Accuracy Resolution Accuracy Resolution 3/5 lead ECG Features > With pulse oxygen, pulse rate monitoring function. > With monitoring function of systolic blood pressure, diastolic blood pressure and mean pressure. > With 3/5 lead ECG, 1 breathing, 2 body temperature monitoring functions. > Provide three patient modes: adult, child and newborn mode. Pressure Range 0-300mmHg Pressure Accuracy ±2mmHg or ±1% (Whichever is greater) Resolution 1mmHg...

Open the catalog to page 3
WITLEAF OEM Solutions Catalog - 4

Range Accuracy Resolution lead type Range Accuracy It is used to monitor the patient's blood oxygen, blood pressure, electrocardiogram, respiration, body temperature, heart rate, and pulse Range Accuracy Resolution Accuracy Resolution With pulse oxygen and pulse rate monitoring function With monitoring function of systolic blood pressure, diastolic blood pressure and mean pressure With 12-lead ECG, 3/5-lead ECG, 1 breathing, 2 body temperature monitoring functions Provide three patient modes: adult, child and newborn mode Pressure Range 0-300mmHg Pressure Accuracy ±2mmHg or ±1% (Whichever...

Open the catalog to page 4
WITLEAF OEM Solutions Catalog - 5

Resolution: 1bpm The M011 integrated multi-parameter module can measure parameters such as ECG, body temperature, blood pressure, blood oxygen, and pulse. Distolic Range Mean Range > With monitoring function of systolic blood pressure, diastolic blood pressure and mean blood pressure Systolic Range > With pulse oxygen, pulse rate monitoring function > With 3-lead ECG, 1-channel body temperature monitoring function > Module thickness is only 25mm, exquisite and compact > Integrated blood pressure gas circuit system design, no need for tracheal connection Electical Specification > With...

Open the catalog to page 5
WITLEAF OEM Solutions Catalog - 6

lead type The M101 monitoring ECG measurement module can measure ECG, respiration, and body temperature, and is used in patient monitoring. With 3/5-lead ECG, 1 breathing, 2 body temperature monitoring functions Patient model: adults, children and newborns Basic resistance Varistor value Electical Specification Power supply Unique ECG analysis function, verified by MIT, AHA database, and passed EC57 standardized test The measurement results include heart rate, body temperature, respiration and ST segment offset values of I, II, and V1 channels > Provide four measurement modes: diagnosis,...

Open the catalog to page 6
WITLEAF OEM Solutions Catalog - 7

Lead type The M108 diagnostic ECG measurement module is a 12-lead ECG, which is used in the diagnosis and analysis of the patient's ECG. With 12-lead ECG waveform display With unique ECG analysis function, verified by MIT database and CSE database Support 255 kinds of auxiliary diagnosis such as arrhythmia, conduction block, myocardial infarction, ventricular hypertrophy, etc. The filter mode can be switched freely Low-pass filter: 70Hz, 100Hz, 150Hz High-pass filter: 0.05Hz, 0.1Hz, 0.2Hz, 0.5Hz Operating Environment Power supply ECG calibration function: input 1mv standard voltage to record...

Open the catalog to page 7
WITLEAF OEM Solutions Catalog - 8

Single Leads ECG Module M101C lead type The M101C single-lead ECG measurement module can measure ECG and is used in patient monitoring. Electical Specification Power supply Power consumption With 3-lead ECG monitoring function Patient model: adult, pediatric and newborn 26 arrhythmia analysis functions, verified by MIT and AHA databases, and passed EC57 standardized tests Provides four measurement modes: diagnosis, monitoring, HARDEST and surgery mode Compliance Standard Diagnosis mode: filter range is 0.05hz~130hz Monitoring mode: filter range is 0.5hz~40hz HARDEST mode: the filtering range is...

Open the catalog to page 8
WITLEAF OEM Solutions Catalog - 9

Pulse Arterial Oxygen Saturation Module M201B The M201B module is used to monitor the patient's pulse oximetry, pulse, and perfusion index Accuracy: Undefined Accuracy: Undefined Electical Specification Power supply With 3-lead ECG monitoring function Patient model: adult, pediatric and newborn 26 arrhythmia analysis functions, verified by MIT and AHA databases, and passed EC57 standardized tests Provides four measurement modes: diagnosis, monitoring, HARDEST and surgery mode Diagnosis mode: filter range is 0.05hz~130hz Monitoring mode: filter range is 0.5hz~40hz HARDEST mode: the filtering range...

Open the catalog to page 9
WITLEAF OEM Solutions Catalog - 10

Pulse Arterial Oxygen Saturation Module M201D Undefined(0~69%) The M201D module is used to monitor the patient's pulse oximetry, pulse, and perfusion index Accuracy: Undefined Accuracy: Undefined Features Electical Specification > With the monitoring function of pulse oxygen, pulse rate, perfusion index and variation index Power supply Patient model: adult, child and newborn Real-time transmission module working status: hardware status, software status and sensor status It has the function of setting the average time of calculation parameters, and obtains the response time of different...

Open the catalog to page 10
WITLEAF OEM Solutions Catalog - 11

Pulse Arterial Oxygen Saturation Module M201U The M201U module is used to monitor the patient's pulse oximetry, pulse, and perfusion index Electical Specification Power supply With the monitoring function of pulse oxygen, pulse rate, perfusion index and variation index Patient model: adult, child and newborn It has the function of setting the average time of calculation parameters, and obtains the response time of different calculation parameters Real-time transmission module working status: hardware status, software status and sensor status Compliance Standard The measurement method is based...

Open the catalog to page 11

All Shenzhen Witleaf Medical Electronics catalogs and technical brochures

  1. E10E12E15

    5 Pages

  2. L10L12L15

    5 Pages