1. Catalogs
  2. Shezhen AITmon Technology Co,.Ltd
  3. ATM-SK401 Medical Keyboard Datasheet
video corpo

ATM-SK401 Medical Keyboard Datasheet

ATM-SK401 Medical Keyboard Datasheet

ATM-SK401 Medical Keyboard Datasheet

Product catalog summary
Main Features:
The ATM-SK401BL is a backlit, wired, sealed silicone keyboard designed for industrial and medical use. It features a full-size layout in a compact, rugged design, offering complete protection against dust and liquids (IP68 rated). The keyboard is easy to clean with hospital-grade antibacterial wipes and sprays, and it supports USB and PS/2 interfaces with plug-and-play functionality. It has a 1.5mm key travel for comfortable typing and can be operated with gloves.

Mechanical Data:
The keyboard includes 105 protuberant rectangular keys with tactile feedback, a switch life of over 6 million operations, and a 1.8m cable length. It is made of 100% silicone, is latex-free, and available in various languages upon request.

Electrical Data:
The keyboard operates at a supply voltage of +5V DC with a current rating of 210mA for PS2 and 220mA for USB. It complies with several standards for radiated emissions and electrostatic discharge, and it uses carbon-on-gold key switch technology.

Applications:
Suitable for medical, material handling, military, industrial, and other environments, the keyboard is ideal for use in settings requiring protection from dust, water, and corrosive liquids.

Environmental Adaptability:
The keyboard operates in temperatures from -10℃ to +55℃ and can be stored between -20℃ and +65℃. It withstands humidity up to 100% and is resistant to shock and vibration.

Reliability:
Certified by FCC, CE, UKCA, RoHS, WEEE, IP68, SGS Antibacterial, and IEC/EN60601-1, the keyboard has a key lifespan of over 8 million actuations, an MTBF of over 50,000 hours, and an MTTR of less than 30 minutes.

Approved Cleaning Solutions:
The keyboard can be cleaned with a variety of solutions, including chlorine, formaldehyde, glutaraldehyde, phenolics, alcohol, NaCIO, oxidizing agents, quaternary ammonium, soap, and warm water. Ultraviolet light can also be used for disinfection. Petroleum-based solvents, acetone, or solutions with more than 10% bleach should not be used as they may damage the product and void the warranty.

Contact Information:
For inquiries, contact [email protected] or [email protected]. Phone: +86-0755-23745625. Address: No. 4, QiShengHuo Artificial Intelligence Park, YouSong Community, LongHua Street, LongHua District, ShenZhen, GuangDong, China 518027.
See more

Catalog excerpts

ATM-SK401 Medical Keyboard Datasheet-1

ATM-SK401 DATASHEET ATM-SK401BL is Backlit Version 1 2019 Aitmon Internal. All rights reserved.

 Open the catalog to page 1
ATM-SK401 Medical Keyboard Datasheet-2

Wired Sealed Silicone Keyboard MAIN FEATURE 1. Keyboard provides Full-size versatility in a rugged, compact design, rugged construction for reliable functionality. 2. Complete protection against dust and liquids according IP68 (submersible) 3. Easy to clean with hospital grade antibacterial wipes and sprays. 4. Interface: USB, PS/2 (Via adapter) Plug and play. no needing of install separate driver. 5. 1.5mm key travel provides comfortable use of typing. 6. Can be operated with gloves. 7. Suitable for all kinds of abluent and bactericides. MECHANICAL DATA IP68 rated Industrial and Medical silicone...

 Open the catalog to page 2
ATM-SK401 Medical Keyboard Datasheet-3

ENVIRONMENTAL ADAPTABILITY 1. Operating temperature: -10℃ to +55℃ 2. Storage temperature: : -20℃ to +65℃ 3. Humidity: 100% 4. Atmospheric pressure: 60-106Kpa 5. Shock: 3x11 ms pulses of 50g on each of 3 axes 6. Vibration: POWER SPECTRAL DENSITY: 0.04g/Hz, FREQUENCY RANGE: 20Hz - 2kHz, DURATION OF TEST PER AXIS: 3 hours 7. Flammability PRINTED CIRCUIT BOARD: 94 VO SILICONE OVERLAY: 94 HB INTERFACE CABLE: 94 V RELIABILITY 1.Certificate: FCC, CE, UKCA, RoHS, WEEE, IP68, SGS Antibacterial, IEC/EN60601-1 2. Key Lifespan > 8 million actuations 3. MTBF > 50000H 4. MTTR < 30min 3 2019 Aitmon Internal....

 Open the catalog to page 3
ATM-SK401 Medical Keyboard Datasheet-4

Approved Cleaning Solutions & Disinfectants: • Most common or commercially available cleaning solutions and disinfectants can be safely used, including: • Chlorine based (max 10% solution) - e.g. Clorox®, Nolvasan®, etc. • Formaldehyde based - e.g. Formaldehyde Solution 37%, etc. • Glutaraldehydebased - e.g. Wavicide-01®, Aldacide® 200, etc. • Phenolics - e.g. Lysol® I.C., Magnaclean Bacteriacide, Tek-Trol® Disinfectant, etc. • Alcohol based - up to max 75%. e.g. CaviCide®, Isopropyl Alcohol, Medicide™ (POL-0.3), etc. • NaCIO based: up to max 0.06% • Oxidizing - Hydrogen Peroxide 3% Solution,...