LC 2010 - 1

Specification Sheet LC-2010 Integrated HPLC System LC-2010C LC-2010A Pump type Serial dual plunger, micro volume (10 µL on primary side, 5 µL on secondary) Flow rate setting range 0.001 ~ 5 mL/min. (1.0 - 35.0 MPa) Flow rate accuracy ± 1% (1 mL/min, 3.0 - 10.0 MPa, using water and fixed ambient temperature of 20°C, except during gradient solvent delivery), ± 2% (except for above conditions) or ± 2 µL/min, whichever is greater Flow rate precision 0.075% RSD or 0.02 min SD, whichever is greater (0.05 - 2 mL/min, 1.0 - 35.0 MPa, methanol 20°C constant temperature) LPGE Number of solvents and setting range Up to 4 solvents 0 to 100%, 0.1% steps Concentration accuracy ± 0.5% (aqueous acetone/water, binary gradient, flow rate 0.1 - 2.0 mL/min, pressure 1.0 - 20.0 MPa) Concentration precision Pump ± 0.1% (aqueous acetone/water, binary gradient, flow rate 0.1 - 2.0 mL/min, pressure 1.0 - 20.0 MPa) Shimadzu Europa GmbH Albert-Hahn-Str.6-10 47269 Duisburg www.shimadzu.de

Open the catalog to page 1
LC 2010 - 2

Specification Sheet: LC-2010 Integrated HPLC System (2/3) LC-2010C LC-2010A Injection Method Variable volume injection possible (without sample loss) Injection volume setting range 0.1 - 100 µL (standard), 1 - 2000 µL (optional) (0.1 - 0.9 µL on 0.1 µL steps, 1 to 2000 µL in 1 µL steps) Sample 1 mL vial capacity 1.5 mL vial Sampler 350 140 210 4 mL vial 100 MTP 4 96- or 384-well micro titer plates DWP 4 96-well deep-well plates Injection repeatability Carry over 0.01% (under napthalene analysis conditions) Injection volume accuracy ± 1% (50 µL, n=6 ) Injection volume correction Possible...

Open the catalog to page 2
LC 2010 - 3

Specification Sheet: LC-2010 Integrated HPLC System (3/3) LC-2010C LC-2010A Deuterium lamp 190 - 600 nm Bandwidth 8 nm Wavelength accuracy ± 1 nm Wavelength precision ± 0.1 nm Drift 1x10-4 AU/h (250 nm air cell) Noise level ± 0.25 x 10-5 AU (for response of 1 s, 250 nm, air cell) Cell path length, cell volume 10 mm, 8 µL (STD flow cell), 5 mm, 2.4 µL (semimicro flow cell) 2 wavelengths monitoring Any two wavelengths from 190 - 370 nm or 371 - 600 nm Display Backlit liquid crystal display (320 x 240 dots), black and white Memory media 3.5 inch floppy disk drive (disk format 2HD, MS-DOS)...

Open the catalog to page 3

All Shimadzu Europa Analytical Instruments catalogs and technical brochures

  1. LCMS-8060NX

    12 Pages

  2. Tracera

    8 Pages

  3. TOC-L

    2 Pages

  4. MOC 63u

    6 Pages

  5. MOC-120H

    4 Pages

  6. GCMS-QP2010

    6 Pages

  7. MALDI-7090

    8 Pages

  8. Catalog EL

    2 Pages

  9. TOC-L Series

    2 Pages

  10. LCMS-IT-TOF

    2 Pages

  11. LCMS-2020

    14 Pages

  12. LCMS-8030

    14 Pages