UV-Vis Spectrophotometer
Open the catalog to page 1Refined User-Friendliness Easy-to-use touch-screen display Faster response speed with adoption of a new CPU Various Functions for Comfortable Daily Measurement User support with assist and shutdown/wakeup functions High Performance to Meet Diverse Needs The instrument is equipped with an ultra high-speed scan, which can acquire a spectrum in a few seconds, with the lowest level of stray light and noise in its class Validation functions enable checks in accordance with Pharmacopoeia (JP/USP/EP) to be performed easily* * Operations are performed via the touch panel of the UV-1900i Plus. If performing...
Open the catalog to page 3Mode Menu I Ready U - S wi f. D2 Maintenance PC Control General Settings The UV-1900i Plus on-screen user interface includes large, easy-to-see icons deployed on a black background, so the instrument settings are evident at a glance. In addition, the large, easy-to-see icons improve intuitive understanding, which enables users to quickly become familiar with the operations. Furthermore, the user interface is designed to minimize transitions between windows, so users do not get confused during the operations. The system also features a faster response speed by adopting a new CPU. Display languages...
Open the catalog to page 4UV-1900i Plus has six basic measurement modes, which offer the optimal solution for a variety of measurements. Measures the photometric value at a single wavelength or multiple (up to eight) wavelengths. Measures a sample spectrum using wavelength scanning. Generates a calibration curve from the measurement of standards, and then calculates the concentrations of unknowns. TActivitv Calculation liannel 5.0 s- 40.0 s Time Course Biomethod Measures changes over time in photometric values at a specified wavelength. Quantifies DNA or protein concentrations. Measures absorbance changes as a function...
Open the catalog to page 5Various Functions for Comfortable Daily Measurement Assist Function The instrument assists the user to ensure that measurements are performed using the correct procedure.*1 Verifies implementation of correction Confirms conditions of correction Checks whether or not baseline correction, auto zero correction or cell blank correction has been performed and informs the user if it has not been. Informs the user if the last correction performed is not appropriate for the planned measurement. Informs the user if the UV-1900i Plus is not ready to begin measurement and when starting measurements and...
Open the catalog to page 6Startup Validation Function Instrument performance checks can be performed automatically when the instrument is turned ON.*2 This enables even more reliable instrument operation. It can also be implemented in combination with the Wakeup function. *2 This function can be enabled/disabled. The performance check items that can be used with this function are as follows: wavelength accuracy (D2), wavelength repeat accuracy (D2), degradation, noise level, baseline flatness, baseline stability (drift), [EP] Control of Wavelength Accuracy (D2), and [USP] Control of Wavelengths (D2). Network Connectivity...
Open the catalog to page 7High Performance to Meet Diverse Needs Low Stray Light Calibration Curve 2.00 Instrument with 1.00 % Stray Light UV-1900 series Linearity will be lost in the high absorbance region due to stray light. UV-1900 series is equipped with Low Stray Light Diffraction Gratings, achieve “best-in-class” low stray light. Stray light is at 0.5 % max. (198 nm), making accurate measurements possible at 1 Abs or more, even in the ultraviolet region. In addition, high-concentration samples can be quantified accurately. The figure on the right is a calibration curve for acetic acid, created with absorbance at...
Open the catalog to page 8Spectra can be acquired as fast as 29,000 nm/min. Ultra-fast scanning is effective for tracking chemical reactions in a short time. In addition to the absorbance change at specified wavelengths, spectra can be acquired in a short time with the UV-1900i Plus. Therefore, more detailed behavior can be investigated by observing spectra with the UV-1900i Plus. The figures below show the analysis of the particle agglomeration process when salts are added to silver nanoparticles. Measurements of the 300 to 700 nm region were performed in ultra-fast scan mode. In addition to the decrease of absorbance...
Open the catalog to page 9Enables Compliance with ER/ES Regulations and Stronger Data Management LabSolutions™ UV-Vis Software Enables higher productivity and provides for a more convenient analytical environment. Different measurement applications can be started from the application launcher. Extensive UV validation software programs supporting instrument performance checks as well as optional software programs for special analyses are also available, so various measurements can be intuitively performed. Four Measurement Mode Windows Setting Parameters Instrument Control Panel Instrument parameter settings can be specified...
Open the catalog to page 10From Measurement to Data Output Improved Productivity of Data Analysis Operations Data analysis and data output operations can be performed at the same time as data measurement. Time spent outputting or analyzing data can also be reduced by simultaneously sending data to an Excel® spreadsheet in real time or saving data as text. The software can also automatically perform postprocessing of measured data, such as processing/correcting spectra, and perform pass/fail judgments of measurement results (automatic spectral evaluation). By specifying various evaluation criteria for measurement results,...
Open the catalog to page 11Reliable LabSolutions Software In addition to LabSolutions UV-Vis, which provides basic functionality, Shimadzu offers LabSolutions DB UV-Vis and LabSolutions CS UV-Vis to meet the requirements of ER/ES regulations. LabSolutions DB UV-Vis LabSolutions DB UV-Vis allows for secure data management by integrating a data management function with LabSolutions UV-Vis. Compliant with ER/ES regulations, the software is optimally configured for customers using a PC. It is recommended for facilities that do not require network connections and want to be ER/ES compliant. LabSolutions CS UV-Vis LabSolutions...
Open the catalog to page 1212 Pages
20 Pages
12 Pages
4 Pages
16 Pages
33 Pages
127 Pages
18 Pages
108 Pages
2 Pages
8 Pages
8 Pages
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
32 Pages
4 Pages
6 Pages
6 Pages
6 Pages
2 Pages
8 Pages
3 Pages
6 Pages
2 Pages
2 Pages
2 Pages
2 Pages
14 Pages
14 Pages
8 Pages
22 Pages
16 Pages
14 Pages
8 Pages