video corpo

DSC-60 Plus Series
8Pages

{{requestButtons}}

Catalog excerpts

DSC-60 Plus Series - 1

Differential Scanning Calorimeter

Open the catalog to page 1
DSC-60 Plus Series - 2

DSC-60 Plus Series Differential Scanning Calorimeter DSC-60 Plus addresses the various DSC applications. The DSC-60 Plus is an indispensable thermal analyzer for materials characterization in R&D and quality control applications in such areas as polymers, pharmaceuticals, electronic parts , foods , etc . It offers the sensitivity and easy operation required for the development of high-performance, highly functional new materials. High sensitivity and high resolution Stable baseline from ultra-low to high temperatures The new detector in the DSC-60 Plus series and the unique furnace...

Open the catalog to page 2
DSC-60 Plus Series - 3

High-sensitivity analysis across the entire measured temperature range High-Sensitivity Measurements of Trace Samples Structure of the DSC-60 Plus Furnace Newly designed the thermal resistance in these parts. Liquid nitrogen Sample Name:Sulfathiazole 0.005mg 0.00 Heater Heat transfer plate Peak Height −0.08mW Thermo-uniformity plate 180.0 Improved the temperature distribution around the heater. Heat radiating fins A stable baseline and S/N performance enable the detection of The new detector and new unique furnace construction a minute calorimetric change during trace analysis. achieves a...

Open the catalog to page 3
DSC-60 Plus Series - 4

Diverse Measurements by Simple Operations The DSC-60 Plus series features a cooling chamber as standard. Measurements below room temperature can be performed by pouring liquid nitrogen through the inlet into the chamber to lower the temperature. This is extremely convenient, as it eliminates the need to install special accessories. It achieves 10 ºC/minute performance at −100 ºC, which is adequate for measurements during a controlled cooling process. It's easy. You only need liquid nitrogen to run the measurements. No need to install any accessories. While running a series of analyses below...

Open the catalog to page 4
DSC-60 Plus Series - 5

Complies with analytical laboratory regulations Thermal analyzers are important analytical instruments for drug development and quality control. This field demands rapid compliance with the PIC/S GMP guidelines. And record/electronic signature (ER/ES) regulations and policies, including the US FDA 21 CFR Part11. Shimadzu thermal analyzers can work collaboratively with various analytical instruments to ensure a laboratory's compliance with the regulations. Integrated Management of Analytical Data by CLASS-Agent Server Office Data search, re-analysis, approval and electronic signature Other...

Open the catalog to page 5
DSC-60 Plus Series - 6

Liquid Nitrogen Auto-cooling System TAC-60L Consecutive Measurement with liquid nitorogen is enabled at a temperature from -130 to 500°C . the cooling capacity is -10°C/min. (at -80°C). The tank internal pressure is optimally controlled according to the residual amount of liquid nitrogen in the tank to keep the supply flow rate constant. Pulsation is reduced, and the DSC baseline remains stable even during cooling measurement. *Requires a separate FC-60A controller Electric Auto-cooling Attachment TAC-60i Consecutive measurement at a temperature from -50 to 500°C is enabled by connecting a...

Open the catalog to page 6
DSC-60 Plus Series - 7

Sample pans Al hermetic pans, ø6 × 1.6 (50/set), limit pressure: 0.3 MPa Pressure-proof stainless steel hermetic pans ø6 × 5 (50/set), limit pressure: 5 MPa Max.500°C Pressure-proof Al hermetic pans ø6 × 5 (50/set), limit pressure: 5 MPa Max.300°C Al (Aluminium) crimp pans + lids, ø6 × 1.5 (50/set) Other pans Al crimp pans and lids for autosampler, ø6 × 3 (100/set) Al hermetic pans for autosampler (DSC) , limit pressure: 0.3MPa, ø4.4 × 4 (100/set) Al hermetic pans for autosampler (DTG) , limit pressure: 0.3MPa, ø6 × 4 (100/set) Copper pans for Autosampler, ø6 × 3 (100/set) Max.300°C DSC-60...

Open the catalog to page 7
DSC-60 Plus Series - 8

Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its affiliates, whether or not they are used with trademark symbol “TM” or “®”. Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. For Research Use Only. Not for use in diagnostic procedures. The contents of this publication are provided to you “as is” without warranty of any kind, and are...

Open the catalog to page 8

All Shimadzu catalogs and technical brochures

  1. UV-1900i

    4 Pages

  2. LCMS-9030

    12 Pages

  3. LCMS-8050

    20 Pages

  4. LCMS-8045

    12 Pages

  5. XRD-6100

    32 Pages

  6. EDX-LE

    16 Pages

  7. PDA-8000

    16 Pages

  8. AA-6200

    12 Pages

  9. UV-3600i Plus

    20 Pages

  10. SPM-9700HT

    27 Pages

  11. SALD-2300

    20 Pages

  12. IG-1000 Plus

    16 Pages

  13. MB140

    4 Pages

  14. MOC63u

    2 Pages

  15. MOC-120H

    4 Pages

  16. MOC63u

    8 Pages

  17. UW/UX Series

    4 Pages

  18. New products

    1 Pages

  19. BL series

    2 Pages

  20. BW-K/BX-K

    2 Pages

  21. MOC-120H

    4 Pages

Archived catalogs

  1. MOC63U Flyer

    2 Pages

  2. UW/UX Series

    4 Pages

  3. SALD-7101

    16 Pages

  4. MOC63U

    6 Pages