Gas Chromatograph Accessories and Supplies
Open the catalog to page 1Gas chromatography requires various peripherals and supplies depending on the analytical purpose, especially as it relates to gas management, flow line configuration, column installation, sample injection and data processing. This brochure introduces various accessories and supplies that support Shimadzu GC instruments. High-end Capillary Gas Chromatograph GC-2010 Plus + Aoc-20i/20s (Option) The GC-2010 Plus represents a new generation in top end capillary GC analysis, redefining sensitivity limits for trace analysis, fast GC applications, and easy, robust operation. Advanced Flow...
Open the catalog to page 2Standard Capillary and Packed Gas Chromatograph GC-2014 Series The GC-2014 offers high expandability and flexibility with the ability to mount multiple injectors and detectors. Available for both packed and capillary columns, it offers an excellent user interface with a large LCD, digital gases control and auto-diagnostics, and innovative technology for all injectors, detectors and flow controllers. • Temperature Range: (Room temperature + 10°C) to 400°C • Carrier Gas Control: Digital setting by electronic flow controller (AFC) Sample Injector: Dual packed, single packed,...
Open the catalog to page 3*1 Applicable models: S Applicable A See article or contact us. Blank is not applicable. *2 Applicable previous models: O Applicable • See article or contact us. © GC-14A © GC-14B © GC-17A Series © GC-1700 © GC-18A © GC-2010
Open the catalog to page 5Integrated Workstation LabSolutions LabSolutions is a next-generation workstation that not only integrates the controls of GC and LC systems but offers improved network functionality. It enables performing all analysis steps automatically from startup to shut down. Log browser has also been improved to help you confirm various analysis results. In addition, a PDF output function is added as a standard feature, which helps promote a paperless laboratory. LabSolutions enables higher operability and productivity. Applicable for GC-2010/2010 Plus, GC-2025 *1, GC-2014, GC-14B *2. * Not...
Open the catalog to page 6Chart Paper Optional Software for Workstation Description Enables distillation GC analysis with LabSolutions. Suitable for ASTM, ISO, EN, JIS standards. Not applicable for GCsolution. Expansion Case (for c-rsa) P/N | 223-04592-91 C-R8A has two slots as standard. This Expansion Case is required if more than three optional boards are installed. PRG-2010 Plus is necessary for controlling valves, pumps and other external devices. It enables the control of the device driven by 24V DC supplied from GC-2010 Plus or GC-2014. An extra PRG BOX is required if a device driven by 100V AC or 230V...
Open the catalog to page 7* For detailed information on Syringes, please refer to page 24.
Open the catalog to page 8Headspace Sampler HS-20 Series Description HS-20 and HS-20 LT (long transfer line) feature a sample loop injection method, while the HS-20 Trap is capable of both sample and trap injection methods. HS-20 Series also enables the analysis of high-boiling compounds due to an oven configurable up to 300 °C and a simple, inert sample line. Note: For the control software, please refer to page 7. Headspace Sampler HS-10 Applicable GC HS-10 headspace sampler is highly cost efficient, yet equipped with advanced features such as a mixing function and the ability to heat-ahead the sample vials waiting...
Open the catalog to page 9Flame Ionization Detector (FID) Description * For dual flow-rate packed column analyses, please choose GC-2014AF or GC-2014ATF, which feature a built-in FID. The flame ionization detector is the most popular detector for gas chromatography because it is highly sensitive to almost all organic compounds. Meanwhile, being little influenced by changes in temperature and flow rate ensures a high signal-to-noise ratio and wide dynamic range. © © Note: Hydrogen and supply air are necessary for FID. Please refer to page 21 for details. Electrode Electrode Voltage Dynamic Range Minimum Detected...
Open the catalog to page 10Interference Filters Use an appropriate filter (sold separately) for your detection target. Three types, for detecting sulfur, phosphorus, and tin, are available. Note 1: Hydrogen and supply air are necessary for FPD. Please refer to page 21 for details. Note 2: During high-sensitivity analysis, it is recommended to use high-purity gas (hydrocarbon less than 1 ppm). In addition, pressure regulators suitable for high-sensitivity analysis are required.
Open the catalog to page 11TCD features a simple design and easy operation, and is able to sense any substances except the carrier gas. A bridge circuit is formed with four matched tungsten-rhenium filaments (100Q, each). When a capillary column (including wide-bore type) is connected to a TCD, it is necessary to use this pipe to supply make-up gas. (The same type of gas used for carrier gas.) Make-up gas supply line parts are not included. AMP-7B enhances the intensity of the TCD signal by a factor of ten. It is equipped with two output terminals, for recorder (0 - 1 mV) and for data processor (0 - IV). It provides...
Open the catalog to page 12Electron Capture Detector (ECD) ECD provides extremely high selective sensitivity to halogen and nitro compounds by using a radioisotope, especially sensitive to chlorinated compounds. It enables reliable detection of chlorinated compounds at the picogram quantity level, such as the trace analysis of chlorinated pesticide residue. To ensure a stable baseline, supply gas (especially nitrogen) must be free of oxygen. Please refer to page 23 for the details of oxygen trap. Specifications Type Radiation Source Electric Current Dynamic Range Minimum Detected Quantity Maximum Operating Temp....
Open the catalog to page 13* Not applicable for GC-2014. With the on-column sample injection method, the sample solution is injected directly into the column and the entire sample is subjected to analysis. As a result, there is no discrimination due to differences in boiling points. It can be used for a wide range of samples with both low and high boiling points. In contrast to the method of injecting into a high-temperature vaporizing chamber, the sample is not heated to a temperature exceeding the column temperature, making it ideal for analyzing thermally labile samples. Maximum Temperature: 450°C (cooling is...
Open the catalog to page 14All Shimadzu catalogs and technical brochures
-
RADspeed Pro EDGE
5 Pages
-
UV-1900i
4 Pages
-
LCMS-9030
12 Pages
-
LCMS-8050
20 Pages
-
LCMS-8045
12 Pages
-
XRD-6100
32 Pages
-
EDX-LE
16 Pages
-
PDA-8000
16 Pages
-
AA-6200
12 Pages
-
UV-3600i Plus
20 Pages
-
SPM-9700HT
27 Pages
-
SALD-2300
20 Pages
-
IG-1000 Plus
16 Pages
-
DSC-60 Plus Series
8 Pages
-
TOC process analysis
16 Pages
-
MB140
4 Pages
-
GC Column Guidebook
48 Pages
-
ATX/ATY Series
6 Pages
-
MOC63u
2 Pages
-
MOC-120H
4 Pages
-
MOC63u
8 Pages
-
UW/UX Series
4 Pages
-
Application Handbook Clinical
140 Pages
-
New products 1
1 Pages
-
New products
1 Pages
-
BL series
2 Pages
-
BW-K/BX-K
2 Pages
-
TX/TXB/TXC Series
8 Pages
-
HMV- 2 brochure
8 Pages
-
AutographA G - XSeries
20 Pages
-
Solutions Brochure
24 Pages
-
PSSM - 8 System
8 Pages
-
MOC-120H
4 Pages
-
AUW-D / AUW / AUX / AUY
8 Pages
Archived catalogs
-
MOC63U Flyer
2 Pages
-
ATX/ATY Series
4 Pages
-
UW/UX Series
4 Pages
-
SALD-7101
16 Pages
-
MOC63U
6 Pages